A comparison between the codes SRIM and AlfaMC in the Monte Carlo simulation of alpha-particle backscattering

被引:2
|
作者
Jurado Vargas, M. [1 ]
Fernandez Timon, A. [2 ]
机构
[1] Univ Extremadura, Dept Fis, Badajoz 06006, Spain
[2] Univ Rey Juan Carlos, Mostoles Madrid 28933, Spain
关键词
Alpha-particle backscattering; Ion interactions in matter; Monte Carlo simulation; Code SRIM; Code AlfaMC; THICK URANIUM-OXIDE; SCATTERING CORRECTION; TRANSPORT; ENERGY;
D O I
10.1007/s10967-015-3982-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The well-known code Stopping and Range of Ions in Matter (SRIM) and the more recent code AlfaMC were used in this work to evaluate the backscattering corrections required in the measurement of alpha particle sources. The differences found in the energy and angular distribution of backscattered particles for point sources mounted on backings of aluminum, silver, and platinum, were analyzed taking into account the models of multiple scattering included in each code. The lateral dispersion of alpha particles and the backscattering coefficients obtained with SRIM were in all the cases some greater than those derived with AlfaMC.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 50 条
  • [41] Monte Carlo simulation of kilovolt positron penetration and backscattering probabilities in solids
    Aydin, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 197 (1-2): : 11 - 16
  • [42] A Dosimetric Comparison Between Superposition Algorithm and Monte Carlo Simulation for SBRT
    Luo, W.
    Meacham, A.
    Molloy, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] ALPHA-PARTICLE TRANSFER BETWEEN ALPHA-DECAYING NUCLEI
    JANECKE, J
    BECCHETTI, FD
    OVERWAY, D
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (07): : 831 - 832
  • [44] A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes
    Papadimitroulas, Panagiotis
    Loudos, George
    Nikiforidis, George C.
    Kagadis, George C.
    MEDICAL PHYSICS, 2012, 39 (08) : 5238 - 5247
  • [45] VECTORIZATION AND PARALLELIZATION OF TRANSPORT MONTE-CARLO SIMULATION CODES
    MIURA, K
    SUPERCOMPUTING /, 1989, 62 : 307 - 324
  • [46] Influence of the low-energy backscattering spectrum on the calibration of thin alpha-particle sources
    Vargas, M. Jurado
    Timon, A. Fernandez
    RADIATION PHYSICS AND CHEMISTRY, 2025, 233
  • [47] DETERMINATION OF ARSENIC, ANTIMONY, AND BISMUTH IN SILICON USING 200 KEV ALPHA-PARTICLE BACKSCATTERING
    HNATOWICZ, V
    KVITEK, J
    KREJCI, P
    PELIKAN, L
    RYBKA, V
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1982, 74 (01): : 323 - 328
  • [48] Monte Carlo simulation of particle detector data stream
    M. Beretta
    M. Biassoni
    L. Gironi
    M. Maino
    M. Nastasi
    L. Pagnanini
    S. Pozzi
    The European Physical Journal Plus, 136
  • [49] Monte carlo simulation for simultaneous particle coagulation and deposition
    Haibo Zhao
    Chuguang Zheng
    Science in China Series E, 2006, 49 : 222 - 237
  • [50] Parallelization of a Monte Carlo particle transport simulation code
    Hadjidoukas, P.
    Bousis, C.
    Emfietzoglou, D.
    COMPUTER PHYSICS COMMUNICATIONS, 2010, 181 (05) : 928 - 936