Static structural testing of trans-tibial composite sockets

被引:0
|
作者
Current, TA [1 ]
Kogler, GF [1 ]
Barth, DG [1 ]
机构
[1] So Illinois Univ, Sch Med, Orthopaed Bioengn Res Lab, Springfield, IL 62794 USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this investigation was to quantify the structural strength of various trans-tibial composite sockets. To conduct the study, loading parameters and methods were developed that emulate the International Standards Organisation (ISO) standards for structural testing of lower limb prostheses since specific guidelines for the testing of the trans-tibial socket portion of a prosthesis have not yet been established. The experimental set-up simulated the instant of maximum loading during the late stance phase of gait. Ten trans-tibial sockets were evaluated. Five different reinforcement materials and two resin types were used to construct the sockets. A standard four hole distal attachment plate was used to connect the socket and pylon. Each sample was loaded to failure in a servo-hydraulic materials test machine at 100 N/s. None of the composites in the study met the ISO 10328 standards for level A100, loading condition II (4025 N), as required for other prosthetic componentry. All failures occurred at the site of the pyramid attachment plate. Ultimate strength and failure type were material dependent. Load point deflection was significantly different for the resin variable (p<0.05). Statistical differences according to reinforcement material were noted in composite weight and strength-to-weight ratio (p<0.05). The fibre volume fraction was also estimated and recorded. Reinforcement material type was the primary determinant of performance for the tested samples. Carbon reinforcements performed better than fibreglass reinforcements of similar weave type. The greatest ultimate strength and strength-to-weight ratio was observed with the unidirectional carbon reinforcement.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 50 条
  • [21] Weight bearing and velocity in trans-tibial and trans-femoral amputees
    Jones, ME
    Bashford, GM
    Mann, JM
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 183 - 186
  • [22] Usability of gait analysis in the alignment of trans-tibial prostheses
    Paul, JP
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (01) : 101 - 101
  • [23] Sand-casting technique for trans-tibial prostheses
    Jensen, JS
    Poetsma, PA
    Thanh, NH
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (02) : 165 - 175
  • [24] CIR sand casting system for trans-tibial socket
    Wu, Y
    Casanova, H
    Smith, WK
    Edwards, M
    Childress, DS
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2003, 27 (02) : 146 - 152
  • [25] GAIT PATTERNS OF ELDERLY MEN WITH TRANS-TIBIAL AMPUTATIONS
    LEMAIRE, ED
    FISHER, FR
    ROBERTSON, DGE
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1993, 17 (01) : 27 - 37
  • [26] EXPERIENCES WITH RESPECT TO THE ICEROSS SYSTEM FOR TRANS-TIBIAL PROSTHESES
    CLUITMANS, J
    GEBOERS, M
    DECKERS, J
    RINGS, F
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1994, 18 (02) : 78 - 83
  • [27] Fibular segment bone bridging in trans-tibial amputation
    Pinto, MAGS
    Harris, WW
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2004, 28 (03) : 220 - 224
  • [28] Evaluation of use and durability of polypropylene trans-tibial prostheses
    Verhoeff, TT
    Poetsma, PA
    Gasser, L
    Tung, H
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1999, 23 (03) : 249 - 255
  • [29] Equilibrium and movement control strategies in trans-tibial amputees
    Viton, JM
    Mouchnino, L
    Mille, ML
    Cincera, M
    Delarque, A
    Pedotti, A
    Bardot, A
    Massion, J
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2000, 24 (02) : 108 - 116
  • [30] Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis
    Narita, H
    Yokogushi, K
    Shii, S
    Kakizawa, M
    Nosaka, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 175 - 178