Reproducibility of ambulatory blood pressure monitoring in daily practice

被引:53
|
作者
van der Steen, MS [1 ]
Lenders, JWM [1 ]
Graafsma, SJ [1 ]
den Arend, J [1 ]
Thien, T [1 ]
机构
[1] Univ Nijmegen St Radboud Hosp, Dept Med, Div Gen Internal Med, NL-6500 HB Nijmegen, Netherlands
关键词
ambulatory blood pressure monitoring (ABPM) reproducibility;
D O I
10.1038/sj.jhh.1000808
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The reproducibility of ambulatory blood pressure monitoring (ABPM) was investigated in 45 untreated hypertensive patients in an out-patient clinic. Subjects with symptoms or diseases which could probably give rise to an increase in blood pressure (BP) variability were excluded. Patients underwent office BP (OBP) measurements and ABPM measurements with the Oxford Medilog device twice. The data were edited following previous set standards. Reproducibility of ABPM was good for the group: 24 h ABPM difference 0/2 mm Hg, standard deviation of the difference (SDD) 12/6 mm Hg for systolic BP and diastolic BP respectively. For OBP the difference between the two visits was 5/2 mm Hg with a SDD of 15/8 mm Hg, Intra-individual reproducibility was poor; almost half of the patients had a systolic difference of more than 10 mm Hg between both ABPM recordings. Reproduciblity of the day-night difference with a BP fall of at least 10% (dipper status) was moderate. About 60% of the subjects were dippers at one of the ABPM recordings but only 42% had a reproducible dip. Possible factors playing a role in the disappointing reproducibility of the ABPM recordings are the difference in daily activities between both recording days, decreased accuracy at higher BP, quality of sleep and the probable lower accuracy of the device during real ambulant conditions. In daily practice ABPM has no better reproducibility than OBP measurements, despite the larger number of measurements.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [31] Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review
    Turner, J. Rick
    Viera, Anthony J.
    Shimbo, Daichi
    AMERICAN JOURNAL OF MEDICINE, 2015, 128 (01): : 14 - 20
  • [32] REPRODUCIBILITY OF AMBULATORY BLOOD-PRESSURE
    MANN, S
    GOULD, BA
    CRAIG, MWM
    RAFTERY, EB
    CLINICAL SCIENCE, 1985, 68 : P42 - P42
  • [33] Reproducibility of the diurnal/nocturnal blood pressure ratio by 48-hour ambulatory blood pressure monitoring
    Hermida, Ramon
    Ayala, Diana
    Calvo, Carlos
    Mojon, Artemio
    Fontao, Maria
    Soler, Rita
    Fernandez, Jose
    JOURNAL OF HYPERTENSION, 2006, 24 : 122 - 122
  • [34] Future developments in ambulatory blood pressure monitoring and self-blood pressure monitoring in clinical practice
    Pickering, T
    BLOOD PRESSURE MONITORING, 2002, 7 (01) : 21 - 25
  • [35] SHORT-TERM REPRODUCIBILITY OF AMBULATORY BLOOD PRESSURE MONITORING: A SYSTEMATIC REVIEW
    Lee, K. P.
    Yip, B.
    Wong, S.
    Tsoi, K.
    Kwong, J.
    Chu, C.
    JOURNAL OF HYPERTENSION, 2018, 36 : E175 - E176
  • [36] The Role of Ambulatory Blood Pressure Monitoring in Current Clinical Practice
    Chia, Justin
    Bhatia, Kunwardeep S.
    Mihailidou, Anastasia S.
    Kanagaratnam, Logan B.
    HEART LUNG AND CIRCULATION, 2022, 31 (10): : 1333 - 1340
  • [37] MONITORING AMBULATORY BLOOD-PRESSURE IN GENERAL-PRACTICE
    WEBB, DJ
    STEWART, MJ
    PADFIELD, PL
    BRITISH MEDICAL JOURNAL, 1992, 304 (6839): : 1442 - 1442
  • [38] MONITORING AMBULATORY BLOOD-PRESSURE IN GENERAL-PRACTICE
    COOPE, J
    COOPE, G
    BRITISH MEDICAL JOURNAL, 1992, 305 (6844): : 53 - 53
  • [39] AMBULATORY BLOOD-PRESSURE MONITORING IN CLINICAL-PRACTICE
    PICKERING, TG
    CLINICAL CARDIOLOGY, 1991, 14 (07) : 557 - 562
  • [40] MONITORING AMBULATORY BLOOD-PRESSURE IN GENERAL-PRACTICE
    SILAGY, C
    LAWRENCE, M
    EBBS, D
    MANT, D
    CONWAY, J
    CLARK, S
    COATS, A
    BRITISH MEDICAL JOURNAL, 1992, 305 (6846): : 181 - 182