Indoor environmental quality of green office buildings in China: Large-scale and long-term measurement

被引:48
|
作者
Geng, Yang [1 ,2 ,3 ]
Lin, Borong [1 ,2 ,3 ]
Yu, Juan [1 ,2 ,3 ]
Zhou, Hao [1 ,2 ,3 ]
Ji, Wenjie [1 ,2 ,3 ]
Chen, Hongzhong [1 ,2 ,3 ]
Zhang, Zhongchen [1 ,2 ,3 ]
Zhu, Yingxin [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Eco Planning & Green Bldg, Beijing, Peoples R China
[3] Tsinghua Univ, Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
Indoor environmental quality (IEQ); Green office building; Long-term measurement; Thermal comfort; Air quality; POSTOCCUPANCY EVALUATION; HEATING-SYSTEMS; THERMAL COMFORT; IEQ; SATISFACTION; HEALTH; PERCEPTION; SYMPTOMS; ENVELOPE; IMPACTS;
D O I
10.1016/j.buildenv.2019.01.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to explore the actual indoor environmental quality (IEQ) in Chinese green office buildings, based on the large-scale and long-term measurement data. A total of 41 green office buildings throughout Cold zone, Hot-Summer-Cold-Winter (HSCW) zone and Hot-Summer-Warm-Winter (HSWW) zone were measured with 198 integrated environmental sensors from June, 2017 to August, 2018. The key findings of this study can be summarized as follows: 1) Indoor thermal comfort did not show a significant difference between climate zones in summer, while thermal environment of Cold zone was much warmer and drier than the counterpart of HSCW and HSWW zone in winter. The overall indoor thermal environment met the standard, although several thermal problems were found; 2) Indoor CO2 concentration was relatively high in summer or winter and low in transition seasons. The median values of indoor CO2 concentration were far below the threshold of 1000 ppm; 3) Indoor PM2.5 concentration was generally lower in HSWW zone and higher in winter. The median values of indoor PM2.5 concentration generally conformed to the standard guideline; 4) The median values of illuminance ranged from 340 lux to 522 lux and all of them reached the lower limit of 300 lux for common offices. The above results were compared with other findings from previous literature and several differences were illustrated. In addition, the correlations between indoor and outdoor environment were found. Other possible factors influencing IEQ were discussed qualitatively.
引用
收藏
页码:266 / 280
页数:15
相关论文
共 50 条
  • [1] Comparative study on the indoor environment quality of green office buildings in China with a long-term field measurement and investigation
    Pei, Zufeng
    Lin, Borong
    Liu, Yanchen
    Zhu, Yingxin
    BUILDING AND ENVIRONMENT, 2015, 84 : 80 - 88
  • [2] Fieldwork Measurement of Indoor Environmental Quality (IEQ) in Malaysian Platinum-Rated Green Office Buildings
    Tharim, Asniza Hamimi Abdul
    Samad, Muna Hanim Abdul
    Ismail, Mazran
    2ND INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND TECHNOLOGY 2017 (ICAST'17), 2017, 1891
  • [3] Sampling method for long-term monitoring of indoor environmental quality in residential buildings
    Yao, Huimin
    Cheng, Xiaojie
    Wei, Shen
    Lv, Yuling
    Li, Ang
    Shen, Xiong
    BUILDING AND ENVIRONMENT, 2022, 215
  • [4] Measured energy use and indoor environment quality in green office buildings in China
    Lin, Borong
    Liu, Yanchen
    Wang, Zhe
    Pei, Zufeng
    Davies, Mike
    ENERGY AND BUILDINGS, 2016, 129 : 9 - 18
  • [5] Importance of Indoor Environmental Quality in Green Buildings
    Patnaik, Alisha
    Kumar, Vikash
    Saha, Purnachandra
    ENVIRONMENTAL POLLUTION, 2018, 77 : 53 - 64
  • [6] Energy consumption, indoor environmental quality, and benchmark for office buildings in Hainan Province of China
    Xiang-fei Kong
    Shi-lei Lü
    Ya-juan Xin
    Wei Wu
    Journal of Central South University, 2012, 19 : 783 - 790
  • [7] Energy consumption,indoor environmental quality,and benchmark for office buildings in Hainan Province of China
    孔祥飞
    吕石磊
    辛亚娟
    吴薇
    JournalofCentralSouthUniversity, 2012, 19 (03) : 783 - 790
  • [8] Energy consumption, indoor environmental quality, and benchmark for office buildings in Hainan Province of China
    Kong Xiang-fei
    Lu Shi-lei
    Xin Ya-juan
    Wu Wei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 783 - 790
  • [9] Analysis of environmental factors affecting the large-scale long-term sequence of green tide outbreaks in the Yellow Sea
    Li, Dongxue
    Gao, Zhiqiang
    Song, Debin
    ESTUARINE COASTAL AND SHELF SCIENCE, 2021, 260
  • [10] How does indoor environmental quality in green refurbished office buildings compare with the one in new certified buildings?
    Lee, Jang-Young
    Wargocki, Pawel
    Chan, Yiong-Huak
    Chen, Liu
    Tham, Kwok-Wai
    BUILDING AND ENVIRONMENT, 2020, 171