Stiffness and Strength Predictions From Finite Element Models of the Knee are Associated with Lower-Limb Fractures After Spinal Cord Injury

被引:9
|
作者
Haider, Ifaz T. [1 ,2 ]
Simonian, Narina [3 ,4 ]
Schnitzer, Thomas J. [3 ]
Edwards, W. Brent [1 ,2 ]
机构
[1] Univ Calgary, Fac Kinesiol, Human Performance Lab, Calgary, AB, Canada
[2] Univ Calgary, McCaig Inst Bone & Joint Hlth, Calgary, AB, Canada
[3] Northwestern Univ, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
[4] Northwestern Univ, Clin & Translat Sci Inst, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
Biomechanics; Fracture risk; Computed tomography; Disuse osteoporosis; POST-YIELD BEHAVIOR; X-RAY ABSORPTIOMETRY; BONE-MINERAL DENSITY; LOWER-EXTREMITIES; PROXIMAL TIBIA; TORSIONAL STIFFNESS; COMPACT-BONE; LUMBAR SPINE; RISK; FEMUR;
D O I
10.1007/s10439-020-02606-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spinal cord injury (SCI) is associated with bone fragility and fractures around the knee. The purpose of this investigation was to validate a computed tomography (CT) based finite element (FE) model of the proximal tibia and distal femur under biaxial loading, and to retrospectively quantify the relationship between model predictions and fracture incidence. Twenty-six cadaveric tibiae and femora (n = 13 each) were loaded to 300 N of compression, then internally rotated until failure. FE predictions of torsional stiffness (K) and strength (T-ult) explained 74% (n = 26) and 93% (n = 7) of the variation in experimental measurements, respectively. Univariate analysis and logistic regression were subsequently used to determine if FE predictions and radiographic measurements from CT and dual energy X-ray absorptiometry (DXA) were associated with prevalent lower-limb fracture in 50 individuals with SCI (n = 14 fractures). FE and CT measures, but not DXA, were lower in individuals with fracture. FE predictions ofT(ult)at the tibia demonstrated the highest odds ratio (4.98;p = 0.006) and receiver operating characteristic (0.84;p = 0.008) but did not significantly outperform other metrics. In conclusion, CT-based FE model predictions were associated with prevalent fracture risk after SCI; this technique could be a powerful tool in future clinical research.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 50 条
  • [21] Soft-plastic brace for lower limb fractures in patients with spinal cord injury
    Uehara, K.
    Akai, M.
    Kubo, T.
    Yamasaki, N.
    Okuma, Y.
    Tobimatsu, Y.
    Iwaya, T.
    SPINAL CORD, 2013, 51 (04) : 327 - 330
  • [22] Soft-plastic brace for lower limb fractures in patients with spinal cord injury
    Meiners, T.
    SPINAL CORD, 2014, 52 (04) : 337 - 337
  • [23] Psoas compartment block for the treatment of lower-limb spasticity caused by spinal cord injury: Report of a case
    Takenaka M.
    Iida H.
    Ohta S.
    Dohi S.
    Journal of Anesthesia, 1997, 11 (4) : 300 - 302
  • [24] An Adaptive Neuromuscular Controller for Assistive Lower-Limb Exoskeletons: A Preliminary Study on Subjects with Spinal Cord Injury
    Wu, Amy R.
    Dzeladini, Florin
    Brug, Tycho J. H.
    Tamburella, Federica
    Tagliamonte, Nevio L.
    van Asseldonk, Edwin H. F.
    van der Kooij, Herman
    Ijspeert, Auke J.
    FRONTIERS IN NEUROROBOTICS, 2017, 11
  • [25] Progression to ambulation following lower limb fractures in an individual with a spinal cord injury: a case report
    Mohanakrishnan Jagadevan
    Bhanumathy Mohanakrishnan
    Salaja Murugesan
    Deep Sharma
    Navin Kumar Agarwal
    Jebaraj Fletcher
    Vengatesan Balasubramanian
    Spinal Cord Series and Cases, 5
  • [26] Response to Soft-plastic brace for lower limb fractures in patients with spinal cord injury
    Uehara, K.
    Akai, M.
    SPINAL CORD, 2014, 52 (04) : 338 - 338
  • [27] Progression to ambulation following lower limb fractures in an individual with a spinal cord injury: a case report
    Jagadevan, Mohanakrishnan
    Mohanakrishnan, Bhanumathy
    Murugesan, Salaja
    Sharma, Deep
    Agarwal, Navin Kumar
    Fletcher, Jebaraj
    Balasubramanian, Vengatesan
    SPINAL CORD SERIES AND CASES, 2019, 5 (01)
  • [28] Response to Soft-plastic brace for lower limb fractures in patients with spinal cord injury
    K Uehara
    M Akai
    Spinal Cord, 2014, 52 : 338 - 338
  • [29] Effect of whole-body vibration on lower-limb EMG activity in subjects with and without spinal cord injury
    Alizadeh-Meghrazi, Milad
    Masani, Kei
    Zariffa, Jose
    Sayenko, Dimitry G.
    Popovic, Milos R.
    Craven, B. Catharine
    JOURNAL OF SPINAL CORD MEDICINE, 2014, 37 (05): : 525 - 536
  • [30] The PPARgamma agonist pioglitazone improves lower-limb paralysis and mechanical allodynia induced by spinal cord injury in mice
    Ono, Koto
    Yamamoto, Shohei
    Tanabe, Mitsuo
    Ono, Hideki
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2008, 106 : 233P - 233P