Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT

被引:20
|
作者
Krombach, GA
Schmitz-Rode, T
Haage, P
DiMartino, E
Prescher, A
Kinzel, S
Günther, RW
机构
[1] Univ Technol, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Technol, Dept Otorhinolaryngol, D-52057 Aachen, Germany
[3] Univ Technol, Dept Anat, D-52057 Aachen, Germany
[4] Univ Technol, Dept Expt Vet Med, D-52057 Aachen, Germany
关键词
temporal bone; semicircular canal dehiscence; magnetic resonance imaging; computed tomography;
D O I
10.1007/s00234-003-0948-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 50 条
  • [41] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [42] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [43] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [44] CARDIAC ABNORMALITIES - ASSESSMENT WITH T2-WEIGHTED TURBO SPIN-ECHO MR-IMAGING WITH ELECTROCARDIOGRAM GATING AT 0.5 T
    SEELOS, KC
    VONSMEKAL, A
    VAHLENSIECK, M
    GIESEKE, J
    REISER, M
    RADIOLOGY, 1993, 189 (02) : 517 - 522
  • [45] Comparison of Sagittal T2-Weighted BLADE and Fast Spin-Echo MRI of the Female Pelvis for Motion Artifact and Lesion Detection
    Lane, Barton F.
    Vandermeer, Fauzia Q.
    Oz, Rasim C.
    Irwin, Eric W.
    McMillan, Alan B.
    Wong-You-Cheong, Jade J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W307 - W313
  • [46] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [47] MRI of the inner ear -: Comparison of axial T2-weighted, three-dimensional turbo spin-echo images, maximum-intensity projections, and volume rendering
    Krombach, GA
    Schmitz-Rode, T
    Tacke, J
    Glowinski, A
    Nolte-Ernsting, CC
    Günther, RW
    INVESTIGATIVE RADIOLOGY, 2000, 35 (06) : 337 - 342
  • [48] The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil
    Namimoto, T
    Yamashita, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 655 - 662
  • [49] T2-weighted fast spin-echo MR imaging of liver.
    Mirowitz, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 263 - 264
  • [50] THE PELVIS - T2-WEIGHTED FAST SPIN-ECHO MR-IMAGING
    NGHIEM, HV
    HERFKENS, RJ
    FRANCIS, IR
    SOMMER, FG
    JEFFREY, RB
    LI, KCP
    STEINER, RM
    GLOVER, GH
    RADIOLOGY, 1992, 185 (01) : 213 - 217