Electronics for a prototype variable field of view PET camera using the PMT-quadrant-sharing detector array

被引:27
|
作者
Li, HD [1 ]
Wong, WH [1 ]
Zhang, N [1 ]
Wang, JM [1 ]
Uribe, J [1 ]
Baghaei, H [1 ]
Yokoyama, S [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.775577
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electronics for a prototype high resolution PET camera with 8 modules of position sensitive detectors has been developed. Each module has 16 EGO blocks (each Mock is composed of 49 crystals). The design goals are component and space reduction. The electronics is composed of 5 parts: front-end analog processing, digital position decoding, fast timing, coincidence processing and master data acquisition. The front-end analog circuit is a zone based structure (each zone has 3x3 PMTs). 9 ADCs digitize integration signals of an active zone identified by 8 trigger clusters (each cluster is composed of 6 PMTs). A trigger corresponding to a gamma ray is sent to a fast timing board to get a rime-mark, and the 9 digitized signals are passed to the position decoding board, where a real block (4 PMTs) can be picked out from the zone for position decoding. Lookup tables are used for energy discrimination and to identify the gamma hit crystal location. The coincidence board opens a 70ns initial timing window, followed by two 20ns true/accidental time-mark lookup table windows. The data output from the coincidence board can be acquired either in sinogram mode or in list-mode with a Motorola/IRONICS VME-based system.
引用
收藏
页码:546 / 550
页数:5
相关论文
共 50 条
  • [41] Development of a small field of view scintimammography camera based on a YAP crystal array and a position sensitive PMT
    Steinbach, D
    Majewski, S
    Williams, M
    Kross, B
    Weisenberger, AG
    Wojcik, R
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1251 - 1256
  • [42] An elongated position sensitive block detector design using the PMT quadrant-sharing configuration and asymmetric light partition
    Wong, WH
    Yokoyama, S
    Uribe, J
    Baghaei, H
    Li, HD
    Wang, JM
    Zhang, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 542 - 545
  • [43] The correction factors for a high resolution variable field of view PET camera.
    Baghaei, H
    Wong, WH
    Uribe, J
    Li, H
    Wang, J
    Zhang, N
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 279P - 279P
  • [44] Development of a small field of view gamma camera using a pixelated CdTe detector
    Ishitsu, T.
    Takahashi, I.
    Tsuchiya, K.
    Kawaguchi, T.
    Yamada, N.
    Amemiya, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S146 - S146
  • [45] Performance Evaluation of an Extended Axial Field of View PET Scanner Prototype with Sparse Detector Module Rings Configuration
    Zein, Sara
    Karakatsanis, Nicolas
    Conti, Maurizio
    Nehmeh, Sadek
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [46] THEORETICAL DECODING RESOLUTION LIMITS OF A PET DETECTOR DESIGN USING QUADRANT SHARING PHOTOMULTIPLIERS AND CROSS-COUPLED BGO
    WONG, WH
    HICKS, K
    NGUYEN, D
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P102 - P102
  • [47] Optofluidic holographic microscopy with custom field of view (FoV) using a linear array detector
    Bianco, V.
    Paturzo, M.
    Marchesano, V.
    Gallotta, I.
    Di Schiavi, E.
    Ferraro, P.
    LAB ON A CHIP, 2015, 15 (09) : 2117 - 2124
  • [48] Performance assessment of a variable field of view and geometry PET animal scanner based on CdTe strip detector blocks
    Descourt, P.
    Mathy, F.
    Maitrejean, S.
    Clement, J. F.
    Comtat, C.
    Trebossen, R.
    Rossetto, O.
    Verger, L.
    Montemont, G.
    Monnet, O.
    Visvikis, D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3832 - +
  • [49] Physical Performance of a PET Scanner Prototype with Extended Axial Field of View using Sparse Detector Module Rings Configuration: A Monte Carlo simulation study
    Zein, S.
    Karakatsanis, N. A.
    Gupta, A.
    Osborne, J. R.
    Nehmeh, S. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S809 - S809
  • [50] Monte Carlo Simulation of the Siemens Biograph Vision PET With Extended Axial Field of View Using Sparse Detector Module Rings Configuration
    Zein, Sara A.
    Karakatsanis, Nicolas A.
    Conti, Maurizio
    Nehmeh, Sadek A.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) : 331 - 342