Optimising sample preparation and near infrared spectra measurements of soil samples to calibrate organic carbon and total nitrogen content

被引:11
|
作者
Miltz, Jasmin [1 ]
Don, Axel [1 ]
机构
[1] Johann Heinrich von Thunen Inst, Inst Agr Climate Res, Braunschweig, Germany
关键词
near infrared (NIR) reflectance spectroscopy; multivariate data analysis; carbon; nitrogen; soil; sample preparation; calibration; DIFFUSE-REFLECTANCE SPECTROSCOPY; NIR; PREDICTION; CLAY;
D O I
10.1255/jnirs.1031
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
There is increasing attention in soil science to using near infrared spectroscopy as a fast and cheap method to analyse various soil properties. However, soil chemical components such as carbon and nitrogen are of low concentrations and analysis is exacerbated by a heterogeneous sample matrix. Thus, for soil analysis, the optimisation of sample preparation and measurement protocols is a prerequisite to establish NIR spectroscopy as a soil analytical method. Several methodological aspects, such as sample-grinding and drying, have been identified as important factors, but results on the best methods still remain inconsistent. The objective of this study was to comprehensively investigate the impact of these factors on a common sample set in order to be able to give recommendations for a standard measurement protocol. The examinations were performed on a set of agricultural soils covering a broad range of soil types, texture classes and carbon and nitrogen content. The number of spectra replicates and size of the sample cups (scanning area 6.8 cm(2) and 19.6 cm(2)) had negligible impact on NIR calibration accuracy. Drying (oven-dried vs air-dried) and grinding (grinding vs crushing and sieving) significantly decreased the calibration error for organic carbon when ground and oven-dried samples were used, whereas these influences were smaller for N (grinding) or had hardly any affect on calibrations (drying). Overall, lowest root mean square error of cross-validation (RMSECV)values were reached for ground, oven-dried samples measured in a large cup (scanning area = 19.6 cm(2)), with 0.391% for C and 0.028% for N. A factorial analysis on the RMSECV for drying, ring cup and grinding, showed the biggest influence on RMSECV by grinding for C with 35% and for N with 28% of the sum of squares accounted for. The effect of varying the laboratory temperature (20 degrees C, 24 degrees C and 28 degrees C) was small when oven-dried samples were used but might have caused a considerable bias in predictions of air-dried samples. In addition, only oven-dried soil samples showed satisfactory reproducibility of predicted values within nine months when NIR measurements were repeated. Since calibrations of different soil parameters seemed to be affected differently by sample preparation and measurement parameters, this study can be considered as a first step towards a standardised measurement protocol.
引用
收藏
页码:695 / 706
页数:12
相关论文
共 50 条
  • [31] Variations of Microbial Communities and the Contents and Isotopic Compositions of Total Organic Carbon and Total Nitrogen in Soil Samples during Their Preservation
    LIU Tung-Sheng
    ActaGeologicaSinica(EnglishEdition), 2009, 83 (01) : 114 - 120
  • [32] SIMULTANEOUS DETERMINATION OF MOISTURE, ORGANIC-CARBON, AND TOTAL NITROGEN BY NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETRY
    DALAL, RC
    HENRY, RJ
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1986, 50 (01) : 120 - 123
  • [33] Peatlands spectral data influence in global spectral modelling of soil organic carbon and total nitrogen using visible-near-infrared spectroscopy
    Mendes, Wanderson de Sousa
    Sommer, Michael
    Koszinski, Sylvia
    Wehrhan, Marc
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 317
  • [34] Long-term effect of tillage, nitrogen fertilization and cover crops on soil organic carbon and total nitrogen content
    Mazzoncini, Marco
    Sapkota, Tek Bahadur
    Barberi, Paolo
    Antichi, Daniele
    Risaliti, Rosalba
    SOIL & TILLAGE RESEARCH, 2011, 114 (02): : 165 - 174
  • [35] Detecting the temporal trend of cultivated soil organic carbon content using visible near infrared spectroscopy
    Zayani, Hayfa
    Fouad, Youssef
    Michot, Didier
    Kassouk, Zeineb
    Lili-Chabaane, Zohra
    Walter, Christian
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2023, 31 (05) : 241 - 255
  • [36] Estimating Soil Organic Carbon Content with Visible-Near-Infrared (Vis-NIR) Spectroscopy
    Gao, Yin
    Cui, Lijuan
    Lei, Bing
    Zhai, Yanfang
    Shi, Tiezhu
    Wang, Junjie
    Chen, Yiyun
    He, Hui
    Wu, Guofeng
    APPLIED SPECTROSCOPY, 2014, 68 (07) : 712 - 722
  • [37] Analysis of peat soil organic carbon, total nitrogen, soil water content and basal respiration: Is there a 'best' drying temperature?
    Dettmann, Ullrich
    Kraft, Nicky Nancy
    Rech, Raimund
    Heidkamp, Arne
    Tiemeyer, Barbel
    GEODERMA, 2021, 403
  • [38] Ammoniated straw incorporation increases wheat yield, yield stability, soil organic carbon and soil total nitrogen content
    Li, Yue
    Feng, Hao
    Dong, Qin'ge
    Xia, Longlong
    Li, Jinchao
    Li, Cheng
    Zang, Huadong
    Andersen, Mathias Neumann
    Olesen, Jorgen Eivind
    Jorgensen, Uffe
    Siddique, Kadambot H. M.
    Chen, Ji
    FIELD CROPS RESEARCH, 2022, 284
  • [39] A COMPARISON OF SAMPLE PREPARATION AND CALIBRATION TECHNIQUES FOR THE ESTIMATION OF NITROGEN, OIL AND GLUCOSINOLATE CONTENT OF RAPESEED BY NEAR-INFRARED SPECTROSCOPY
    STARR, C
    SUTTLE, J
    MORGAN, AG
    SMITH, DB
    JOURNAL OF AGRICULTURAL SCIENCE, 1985, 104 (APR): : 317 - 323
  • [40] Predicting Soil Organic Carbon and Total Nitrogen at the Farm Scale Using Quantitative Color Sensor Measurements
    Stiglitz, Roxanne Y.
    Mikhailova, Elena A.
    Sharp, Julia L.
    Post, Christopher J.
    Schlautman, Mark A.
    Gerard, Patrick D.
    Cope, Michael P.
    AGRONOMY-BASEL, 2018, 8 (10):