Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode

被引:115
|
作者
Loyprasert, Suchera [1 ,2 ]
Thavarungkul, Panote [2 ,3 ]
Asawatreratanakul, Punnee [2 ,4 ]
Wongkittisuksa, Booncharoen [2 ,5 ]
Limsakul, Chusak [2 ,5 ]
Kanatharana, Proespichaya [1 ,2 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Engn, Dept Elect Engn, Hat Yai 90112, Songkhla, Thailand
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 24卷 / 01期
关键词
label-free immunosensor; self-assembled monolayer; Ag nanoparticle; microcystin-LR; capacitance measurement;
D O I
10.1016/j.bios.2008.03.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free immunosensor based on a modified gold electrode incorporated with silver(Ag) nanoparticles (NPs) to enhance the capacitive response to microcystin-LR (MCLR) has been developed Anti-microcystin-LR (anti-MCLR) was immobilized on silver nanoparticles bound to a self-assembled thiourea monolayer Interaction ofanti-MCLR and MCLR were directly detected by capacitance measurement. Under optimum conditions, MCLR could be determined with a detection limit of 7.0 pg l(-1) and linearity between 10 pg l(-1) and 1 mu g l(-1). The immobilized anti-MUR oil self-assembled thiourea monolayer incorporated with silver nanoparticles was stable and good reproducibility of the signal could be obtained up to 43 times with an R.S.D. of 2.1%. Comparing to the modified electrode without silver nanoparticles it gave 1.7-fold higher sensitivity and lower limit of detection. The developed immunosensor was applied to analyze MCLR in water samples and the results were in good agreement with those obtained by high-performance liquid chromatography (HPLC) (P < 0.05). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 86
页数:9
相关论文
共 50 条
  • [1] Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticles
    Ping Tong
    Shurong Tang
    Yu He
    Yanhong Shao
    Lan Zhang
    Guonan Chen
    Microchimica Acta, 2011, 173 : 299 - 305
  • [2] Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticles
    Tong, Ping
    Tang, Shurong
    He, Yu
    Shao, Yanhong
    Zhang, Lan
    Chen, Guonan
    MICROCHIMICA ACTA, 2011, 173 (3-4) : 299 - 305
  • [3] Label-free Immunosensor Using a Gold Electrode Covered with Conductive Self-assembled Monolayer
    Takoh, Kimiyasu
    Horie, Mika
    Someya, Hiroko
    Ishida, Masahiko
    Kamijo, Ken'ichi
    2010 IEEE SENSORS, 2010, : 411 - 414
  • [4] Label-Free Immunosensor for the Determination of Microcystin-LR in Water
    Almeida de Oliveira, Ravila
    Zanato, Nicole
    Cruz Vieira, Iolanda
    ELECTROANALYSIS, 2020, 32 (10) : 2166 - 2173
  • [5] Microcystin-LR label-free immunosensor based on exfoliated graphite nanoplatelets and silver nanoparticles
    Zanato, Nicole
    Talamini, Lucas
    Silva, Tania Regina
    Vieira, Iolanda Cruz
    TALANTA, 2017, 175 : 38 - 45
  • [6] An Electrochemical Immunosensor Based on a Self-Assembled Monolayer Modified Electrode for Label-Free Detection of α-Synuclein
    Ge, Chuang-Ye
    Rahman, Md. Mahbubur
    Zhang, Wei
    Lopa, Nasrin Siraj
    Jin, Lei
    Yoon, Sujin
    Jang, Hohyoun
    Xu, Guang-Ri
    Kim, Whangi
    SENSORS, 2020, 20 (03)
  • [7] A SIMPLE, HIGHLY SENSITIVE, AND LABEL-FREE IMPEDIMETRIC IMMUNOSENSOR FOR DETECTION OF MICROCYSTIN-LR IN WATER
    Sun, Xiulan
    Shi, Hui
    Wang, Hongxin
    Xiao, Liwen
    Li, Luning
    ANALYTICAL LETTERS, 2010, 43 (04) : 533 - 544
  • [8] Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin
    Gobi, K. Vengatajalabathy
    Iwasaka, Hiroyuki
    Miura, Norio
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1382 - 1389
  • [9] Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples
    Tan, Feng
    Saucedo, Nuvia Maria
    Ramnani, Pankaj
    Mulchandani, Ashok
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (15) : 9256 - 9263
  • [10] Sensitive Detection of Microcystin-LR by Using a Label-Free Electrochemical Immunosensor Based on Au Nanoparticles/Silicon Template/Methylene Blue Nanocomposite
    Fu, Xuewen
    Feng, Yajuan
    Niu, Sipeng
    Zhao, Chunling
    Yang, Minghui
    Yang, Yunhui
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (12) : 8245 - 8252