PERFORMANCE ADVANCEMENT OF RC COLUMNS BY APPLYING BASALT FRP COMPOSITES WITH NSM AND CONFINEMENT SYSTEM

被引:21
|
作者
Ding, Lining [1 ]
Wu, Gang [1 ]
Yang, Shenyin [1 ]
Wu, Zhishen [1 ]
机构
[1] Southeast Univ, Natl & Local Unite Engn Res Ctr Basalt Fiber Prod, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Basalt FRP composite; near surface mounted (NSM); confinement; seismic performance; RC columns; REPAIR;
D O I
10.1142/S1793431113500073
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Basalt fiber reinforced polymer (BFRP) composites are regarded as promising structural strengthening material due to their environmental friendly and superior mechanical and chemical properties. In order to enhance the overall seismic performance of RC columns, a strengthening system is developed by applying BFRP composites with both near surface mounted (NSM) and confinement approaches. The variables taken into account consisted of the diameters and anchorage lengths of BFRP bars, as well as the confinement amounts of BFRP sheets. A total of eight column specimens including one control were tested subjected to simultaneous axial compression and cyclic bend. The structural performance such as load capacity, displacement, ductility, stiffness degradation, energy dissipation capacity, curvature and post-yield stiffness were investigated. The test results indicate that the combination of NSM and confinement techniques contributes to the comprehensive performance enhancement of RC columns, which lies in (1) constantly enlarging diameters of BFRP bars increases the yield and peak loads, the ultimate displacement, the initial and post-yield stiffness as well as the ductility, whereas it has no obvious influence on the yield displacement; (2) longer bonding length results in higher seismic performances although it makes no changes to the yield displacement, the post-yield stiffness, and the degradation of strength and stiffness as well; (3) the adoption of BFRP confinement significantly improves the ductility and the strength degradation performance; (4) the largest post-yield stiffness can be achieved by enlarging diameter to 12 mm, whereas the ductility and the strength degradation characteristics deteriorate due to the weakness of interfacial bonding between BFRP bars and concrete.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Seismic Performance of FRP-Confined Circular RC Columns
    Wang, Z. Y.
    Wang, D. Y.
    Sheikh, S. A.
    Liu, J. T.
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 810 - +
  • [22] Experimental study on Earthquake-damaged RC Frame Columns repaired with Sprayed Basalt FRP
    Bitewlgn, Getahune M.
    Gu Qian
    Li Bo
    Sun Chengfang
    ENGINEERING SOLUTIONS FOR MANUFACTURING PROCESSES IV, PTS 1 AND 2, 2014, 889-890 : 1438 - +
  • [23] Fiber-Element Modeling for Seismic Performance of Square RC Bridge Columns Retrofitted with NSM BFRP Bars and/or BFRP Sheet Confinement
    Yao, Liu-Zhen
    Wu, Gang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (04)
  • [24] Application of innovative basalt-phenolic FRP rebars in improving fire resistance of RC beam strengthened with NSM technology
    Li, Ting
    Huang, Jinqiao
    Gu, Guangxin
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 458
  • [25] Strength and ductility of innovative hybrid NSM reinforced and FRP confined short RC columns under axial compression
    Chellapandian, M.
    Prakash, S. Suriya
    Sharma, Akanshu
    COMPOSITE STRUCTURES, 2017, 176 : 205 - 216
  • [26] Performance of Concentrically Loaded RC Wall-like Columns Upgraded with Innovative Hybrid NSM/CFRP System
    Elsanadedy, Hussein
    Abbas, Husain
    Almusallam, Tarek
    Al-Salloum, Yousef
    POLYMERS, 2023, 15 (02)
  • [27] Probabilistic capacity models and fragility estimates for RC columns retrofitted with FRP composites
    Tabandeh, Armin
    Gardoni, Paolo
    ENGINEERING STRUCTURES, 2014, 74 : 13 - 22
  • [28] Rehabilitation of partially damaged high strength RC corbels by EB FRP composites and NSM steel bars
    Shakir, Qasim M.
    Abdlsaheb, Sarah D.
    STRUCTURES, 2022, 38 : 652 - 671
  • [29] Performance of corner strips in CFRP confinement of rectilinear RC columns
    Ilia, E.
    Mostofinejad, D.
    Moghaddas, A.
    SCIENTIA IRANICA, 2015, 22 (06) : 2024 - 2032
  • [30] NSM techniques versus FRP and TRM composites for flexural enhancement of RC beams: FE comparative study
    Elsanadedy, Hussein M.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2025, 10 (03)