Simultaneous profiling and quantification of 25 eicosanoids in human serum by ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry

被引:6
|
作者
Lu, Yuanyuan [2 ]
Mai, Zhitong [4 ]
Zhou, Hongxia [3 ]
Guan, Wenda [1 ]
Wu, Shiguan [1 ]
Zou, Heyan [3 ]
Shen, Maoting [3 ]
Zhan, Yangqing [1 ]
Ye, Feng [1 ]
Qiu, Minshan [3 ]
Shen, Lihan [3 ]
Zhao, Beibei [2 ]
Yang, Zifeng [1 ,4 ,5 ,6 ]
机构
[1] Guangzhou Med Univ, Natl Clin Res Ctr Resp Dis, Guangzhou Inst Resp Hlth, State Key Lab Resp Dis,Affiliated Hosp 1, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou KingMed Ctr Clin Lab Co Ltd, Gaungzhou 510000, Guangdong, Peoples R China
[3] Southern Med Univ, Affiliated Dongguan Hosp, Dongguan Inst Resp & Crit Care Med, Dept Crit Care Med, Dongguan 523059, Guangdong, Peoples R China
[4] Macau Univ Sci & Technol, Macau Inst Appl Res Med & Hlth, State Key Lab Qual Res Chinese Med, Taipa, Macao, Peoples R China
[5] Guangzhou Lab, Guangzhou 510000, Peoples R China
[6] Guangzhou Key Lab Clin Rapid Diag & Early Warning, Guangzhou 510000, Guangdong, Peoples R China
关键词
Eicosanoids; LC-MS/MS; Bacteria; Severe pneumonia; INFECTION; LIPIDOMICS;
D O I
10.1007/s00216-022-04351-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The eicosanoid metabolic pathway is responsible for mediating the production of various inflammatory factors that are closely related to the development and resolution of inflammation. In biological matrices, the major quantifying obstacles were shown to be the oxidation and low quantities of eicosanoids and their metabolites. This study aimed to develop a reliable, sensitive ultrahigh-performance liquid chromatography coupled to a tandem mass spectrometry (UPLC-MS/MS) method to quantify eicosanoids in human serum. Solid-phase extraction (SPE) was used for sample preparation. The approach employed continuous ionization polarity switching. The target eicosanoids showed good linearity over the investigated concentration range (r2 > 0.99). The recovery rates were over 64.5%, and the matrix effects ranged from 73.0 to 128.0%. The limits of quantification were 0.048 similar to 0.44 ng/mL. For the broad concentration range, the CV % for accuracy and precision were less than +/- 20%. We successfully applied this method to rapidly analyse 74 serum samples from severe influenza pneumonia, severe bacterial pneumonia and healthy individuals. Eicosanoid-related metabolite concentrations were quantified within a range similar to those of previously published articles. Compared to healthy individuals, our application found that 20-HETE, 14,15-EET and 11,12-EET were upregulated in severe influenza pneumonia patients, while LTB4 was downregulated. 8-HETE and 5-HETE were upregulated in severe bacterial pneumonia patients, while LTE4 was downregulated. This approach provides a means for monitoring the low quantities of eicosanoids in biological matrices, and our finding that different characteristic metabolite profiles may help discriminate the induction of severe pneumonia patients .
引用
收藏
页码:8233 / 8244
页数:12
相关论文
共 50 条
  • [42] Simultaneous Quantification of Seven Antifungal Agents in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry
    Li, Wenjing
    Li, Yang
    Cai, Junlong
    Wang, Yue
    Liu, Yanan
    Hu, Hankun
    Liu, Liang
    PHARMACEUTICALS, 2023, 16 (11)
  • [43] Simultaneous Determination of 12 Bioactive Constituents in Bupi Yiqi No. 1 Recipe by Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry
    Xie, Qingling
    Li, Bin
    Huang, Feibing
    Cao, Mengru
    Yuan, Hanwen
    Liu, Yongbei
    Li, Wei
    Qiu, Yixing
    Zhou, Xiaoling
    Man, Rongyong
    Wang, Wei
    Zhang, Weining
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (01) : 117 - 123
  • [44] Determination of Nine Bisphenol-Diglycidyl Ethers in Human Breast Milk by Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry
    Yang, Runhui
    Niu, Yumin
    Wang, Bin
    Zhang, Jing
    Shao, Bing
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (37) : 9810 - 9818
  • [45] Simultaneous quantification of tetrahydrobiopterin, dihydrobiopterin, and biopterin by liquid chromatography coupled electrospray tandem mass spectrometry
    Fismen, Lise
    Eide, Torunn
    Djurhuus, Rune
    Svardal, Asbjorn M.
    ANALYTICAL BIOCHEMISTRY, 2012, 430 (02) : 163 - 170
  • [46] Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography–tandem mass spectrometry
    Jaivik V.Shah
    Priyanka A.Shah
    Mallika Sanyal
    Pranav S.Shrivastav
    Journal of Pharmaceutical Analysis, 2017, 7 (05) : 288 - 296
  • [47] Simultaneous quantification of carbamate insecticides in human plasma by liquid chromatography/tandem mass spectrometry
    Mostafa, Ahmed
    Medley, Gregory
    Roberts, Darren M.
    Mohamed, Mosaad Sayed
    Elshanawani, Abdalla A.
    Roberts, Michael S.
    Liu, Xin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2234 - 2238
  • [48] Simultaneous quantification of fludarabine and cyclophosphamide in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Silvertand, LHH
    Vazvaei, F
    Weigl, P
    Rosing, H
    Hillebrand, MJX
    van Maanen, MJ
    Beijnen, JH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (24) : 3673 - 3680
  • [49] The analysis of azocyclotin and cyhexatin residues in fruits using ultrahigh-performance liquid chromatography-tandem mass spectrometry
    Ma, You-Ning
    Gui, Wen-Jun
    Zhu, Guo-Nian
    ANALYTICAL METHODS, 2015, 7 (05) : 2108 - 2113
  • [50] Quantification of artemisinin in human plasma using liquid chromatography coupled to tandem mass spectrometry
    Lindegardh, N.
    Tarning, J.
    Toi, P. V.
    Hien, T. T.
    Farrar, J.
    Singhasivanon, P.
    White, N. J.
    Ashton, M.
    Day, N. P. J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 768 - 773