Gold nanoparticles/polyaniline Langmuir-Blodgett Film modified glassy carbon electrode as voltammetric sensor for detection of epinephrine and uric acid

被引:37
|
作者
Zou, Lina [1 ]
Li, Yinfeng [1 ,2 ]
Cao, Shaokui [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450001, Peoples R China
[2] Henan Univ Urban Construct, Sch Chem & Mat Engn, Pingdingshan 467036, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Langmuir-Blodgett Film; Polyaniline; Voltammetric sensor; Epinephrine; Uric acid; ASCORBIC-ACID; NANOCOMPOSITE; FABRICATION;
D O I
10.1016/j.talanta.2013.09.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoparticles/polyaniline nanocomposite thin film was deposited onto the surface of glassy carbon electrode(GCE) by Langmuir-Blodgett(LB) technology to fabricate a new voltammetric sensor (GNPs/PAn-LB GCE) for epinephrine(EP) and uric acid(UA) detection. Cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy were employed to study the characteristic of the GNPs/PAn-LB film. Electrochemical behaviors of EP and UA at the modified electrode were investigated in pH 6.6 phosphate buffer solutions. A sensitive electroanalytical method for simultaneous determination of EP and UA was proposed with high precision and good reproducibility. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [21] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [22] Incorporation of gold nanoparticles into Langmuir-Blodgett films of polyaniline and montmorillonite for enhanced detection of metallic ions
    De Barros, A.
    Constantino, C. J. L.
    Bortoleto, J. R. R.
    Da Cruz, N. C.
    Ferreira, M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 408 - 417
  • [23] Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode
    WANG Juan~1
    2. Department of Environmental Engineer
    WuhanUniversityJournalofNaturalSciences, 2005, (05) : 913 - 918
  • [24] IMPRINTING ZEOLITE-MODIFIED GLASSY CARBON AS A VOLTAMMETRIC SENSOR FOR URIC ACID
    Khasanah, Miratul
    Harsini, Muji
    Widati, Alfa Akustia
    INDONESIAN JOURNAL OF CHEMISTRY, 2013, 13 (02) : 108 - 113
  • [25] A new voltammetric sensor for sensitive and selective determination of xanthine based on DNA and polyaniline composite Langmuir-Blodgett film
    Zou, Lina
    Li, Yinfeng
    Cao, Shaokui
    Ye, Baoxian
    TALANTA, 2014, 129 : 346 - 351
  • [26] Langmuir-Blodgett Film of Asymmetric Calix[4]arene Derivative Modified Electrode for Voltammetric Determination of Silver
    Zou, Lina
    Wu, Xianli
    Li, Yamin
    Yang, Baocheng
    Zhang, Shusheng
    Ye, Baoxian
    CLEAN-SOIL AIR WATER, 2011, 39 (03) : 238 - 243
  • [27] Gold nanoparticles/ethylenediamine/carbon nanotube modified glassy carbon electrode as the voltammetric sensor for selective determination of rutin in the presence of ascorbic acid
    Yang, Suling
    Qu, Lingbo
    Li, Gang
    Yang, Ran
    Liu, Cuicui
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 645 (02) : 115 - 122
  • [28] Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube
    Noroozifar, M.
    Khorasani-Motlagh, M.
    Akbari, R.
    Parizi, M. Bemanadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2014, 1 (01): : 62 - 72
  • [29] A selective sensor based on a glassy carbon electrode modified with carbon nanotubes and ruthenium oxide/hexacyanoferrate film for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    ANALYTICAL METHODS, 2011, 3 (10) : 2367 - 2373
  • [30] Simultaneous determination of epinephrine and uric acid at ordered mesoporous carbon modified glassy carbon electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Ding, Yaping
    Zhang, Zhao
    Deng, Dongmei
    Lu, Bo
    ANALYTICAL METHODS, 2012, 4 (08) : 2417 - 2422