The removal of strontium from simulated Hanford tank wastes containing complexants

被引:9
|
作者
Sylvester, P [1 ]
Clearfield, A [1 ]
机构
[1] Texas A&M Univ, Dept Chem, College Stn, TX 77842 USA
关键词
nuclear waste; ion exchange; strontium; Hanford; complexants;
D O I
10.1081/SS-100100789
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Two inorganic ion-exchange materials, a sodium nonatitanate and a sodium titanosilicate, were evaluated for the removal of strontium from two simulated Hanford tank wastes, both of which contained substantial amounts of complexing agents. In simulant 101-SY, both exchangers gave distribution coefficients (K(d)s) < 220 mL/g at a volume-to-mass ratio of 200. However, in a second simulant, 107-AN, the titanosilicate gave a K-d Of 2240 mL/g while the nonatitanate gave a similar Kd to the value obtained in the 101-SY simulant. The reason for the difference in behavior was determined to be the concentration of calcium in the waste simulants. A high calcium concentration las found in 107-AN, resulted in strontium, previously chelated by EDTA and other complexants, being released into solution and absorbed by the titanosilicate. Consequently, by adding sufficient calcium to 101-SY simulant to saturate the EDTA present, it proved possible to improve the strontium K(d)s for the titanosilicate from 215 mL/g to in excess of 8000 mL/g. The titanate exhibited a high selectivity for calcium in comparison to the titanosilicate, and thus the high concentrations of calcium in the waste simulants competed with the strontium ions for the available ion-exchange sites and resulted in low Sr KdS As expected, KdS for the titanate showed little improvement, and the addition of calcium only resulted in a modest increase from 185 to 395 mL/g. Waste generation is minimal, so the addition of calcium to the tank wastes to facilitate the removal of strontium by ion exchange is an economical approach to the remediation of complexant-bearing Hanford tank wastes.
引用
收藏
页码:2539 / 2551
页数:13
相关论文
共 50 条
  • [21] Effect of temperature on SuperLig® 644 cesium removal from simulated Hanford tank waste supernate
    Hassan, NM
    Nash, CA
    Saito, HH
    Marra, JC
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 258 (01) : 21 - 31
  • [22] Effect of temperature on SuperLig® 644 cesium removal from simulated Hanford tank waste supernate
    N. M. Hassan
    C. A. Nash
    H. H. Saito
    J. C. Marra
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 258 : 21 - 31
  • [23] The removal of strontium and cesium from simulated hanford groundwater using inorganic ion exchange materials
    Sylvester, P
    Clearfield, A
    SOLVENT EXTRACTION AND ION EXCHANGE, 1998, 16 (06) : 1527 - 1539
  • [24] The removal of strontium and cesium from simulated hanford groundwater using inorganic ion exchange materials
    Department of Chemistry, Texas A and M University, PO Box 300012, College Station, TX 77842-3012, United States
    Solvent Extr. Ion Exch., 6 (1527-1539):
  • [25] Qualifications of Raman analysis on Hanford tank wastes
    Crawford, BA
    Kyle, KR
    SCIENCE AND TECHNOLOGY FOR DISPOSAL OF RADIOACTIVE TANK WASTES, 1998, : 127 - 134
  • [26] PHYSICAL AND RHEOLOGICAL CHARACTERIZATION OF HANFORD TANK WASTES
    TINGEY, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 87 - IEC
  • [27] Analysis and quantification of organic acids in simulated Hanford tank waste and Hanford tank waste
    Sharma, AK
    Clauss, SA
    Mong, GM
    Wahl, KL
    Campbell, JA
    JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) : 101 - 107
  • [28] Removal of technetium from Hanford tank waste supernates
    Burgeson, IE
    Deschane, JR
    Blanchard, DL
    SEPARATION SCIENCE AND TECHNOLOGY, 2005, 40 (1-3) : 201 - 223
  • [30] Ion chromatography of Hanford tank wastes.
    Melethil, PK
    ONeill, MM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 177 - IEC