The cost of parallel imaging in functional MRI of the human brain

被引:18
|
作者
Lütcke, H
Merboldt, KD
Frahm, J
机构
[1] Biomed NMR Forschungs GmbH, D-37070 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, D-37070 Gottingen, Germany
关键词
magnetic resonance imaging; parallel acquisitions; echo-planar imaging; functional brain mapping;
D O I
10.1016/j.mri.2005.10.028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While the advantages of parallel acquisition techniques for echo-planar imaging (EPI) are well documented for studies affected by magnetic field inhomogeneities, this work focuses on the costs in functional MRI of brain regions without artifacts due to susceptibility effects. For a visual stimulation paradigm and relative to conventional EPI (2.9 T; TR/TE=2000/36 ins), the use of parallel acquisition at a reduction factor of 2 decreased the mean number of activated voxels by 21% at 2 x 2 x 2-mm(3) resolution (n = 6) and by 15% at 3 x 3 x 3-mm(3) resolution (n=6). The loss of sensitivity reflects both a decreased signal-to-noise ratio of the native images due to a lower number of contributing gradient echoes and a decreased BOLD MRI sensitivity due to the coverage of a smaller range of TEs. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] Human brain functional imaging with reflectance CWS
    Nioka, S
    Luo, Q
    Chance, B
    OXYGEN TRANSPORT TO TISSUE XIX, 1997, 428 : 237 - 242
  • [22] Functional magnetic resonance imaging of the human brain
    Kim, SG
    Ugurbil, K
    JOURNAL OF NEUROSCIENCE METHODS, 1997, 74 (02) : 229 - 243
  • [23] Intraoperative infrared functional imaging of human brain
    Gorbach, AM
    Heiss, J
    Kufta, C
    Sato, S
    Fedio, P
    Kammerer, WA
    Solomon, J
    Oldfield, EH
    ANNALS OF NEUROLOGY, 2003, 54 (03) : 297 - 309
  • [24] 3-DIMENSIONAL FUNCTIONAL IMAGING OF HUMAN BRAIN USING ECHO-SHIFTED FLASH MRI
    DUYN, JH
    MATTAY, VS
    SEXTON, RH
    SOBERING, GS
    BARRIOS, FA
    LIU, GY
    FRANK, JA
    WEINBERGER, DR
    MOONEN, CTW
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) : 150 - 155
  • [25] Improvements in Parallel Imaging Accelerated Functional MRI Using Multiecho Echo-Planar Imaging
    Schmiedeskamp, Heiko
    Newbould, Rexford D.
    Pisani, Laura J.
    Skare, Stefan
    Glover, Gary H.
    Pruessmann, Klaas P.
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 959 - 969
  • [26] High temporal resolution functional MRI using parallel echo volumar imaging
    Rabrait, Cecile
    Ciuciu, Philippe
    Ribes, Alejandro
    Poupon, Cyril
    Le Roux, Patrick
    Dehaine-Lambertz, Ghislaine
    Le Bihan, D.
    Lethimonnier, F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 744 - 753
  • [27] Structural and functional correlates of visual field asymmetry in the human brain by diffusion kurtosis MRI and functional MRI
    O'Connell, Caitlin
    Ho, Leon C.
    Murphy, Matthew C.
    Conner, Ian P.
    Wollstein, Gadi
    Cham, Rakie
    Chan, Kevin C.
    NEUROREPORT, 2016, 27 (16) : 1225 - 1231
  • [28] Functional MRI of the brain
    Langevin, F
    Cuenod, CA
    JOURNAL DE RADIOLOGIE, 1996, : 61 - 64
  • [29] Functional brain MRI
    Soulie, D
    Leveque, C
    Nioche, C
    Hertz-Pannier, L
    Belin, C
    Cordoliani, YS
    JOURNAL OF NEURORADIOLOGY, 1998, 25 (02) : 94 - 100
  • [30] Massively parallel functional photoacoustic computed tomography of the human brain
    Na, Shuai
    Russin, Jonathan J.
    Lin, Li
    Yuan, Xiaoyun
    Hu, Peng
    Jann, Kay B.
    Yan, Lirong
    Maslov, Konstantin
    Shi, Junhui
    Wang, Danny J.
    Liu, Charles Y.
    Wang, Lihong, V
    NATURE BIOMEDICAL ENGINEERING, 2022, 6 (05) : 584 - 592