Tissue engineering of meniscal cartilage

被引:0
|
作者
Neves, AA [1 ]
Medcalf, N [1 ]
Brindle, KM [1 ]
机构
[1] Univ Cambridge, Dept Biochem, Cambridge CB2 1GA, England
来源
ANIMAL CELL TECHNOLOGY: FROM TARGET TO MARKET | 2001年 / 1卷
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Fifty years ago it was shown that removal of a diseased meniscus in the knee joint led in the long term to cartilage degeneration and bone remodelling (Fairbank, 1948). This observation changed substantially the therapeutic approach adopted, with the ruptured meniscus being repaired instead of removed. However, this treatment is only feasible when the meniscal tissue is of good quality, which is often not the situation in the clinic. Concerns regarding disease transmission, immunogenicity, sizing, and availability of meniscal allografts have stimulated the search for a tissue-engineered (TE) structure that could replace the function of the native tissue. Previous studies have shown the relevance of fluid flow in the in vitro synthesis of cartilaginous tissues (Rotter et al., 1998). The constant availability of fresh media, the mechanical action of shear stress on the cells and the ability to transport nutrients through an increasingly dense extracellular matrix (ECM), are some of the reasons that favor the use of perfusion culture for the generation of bioartificial cartilage. However, optimal flow parameters for the generation of meniscal tissue have yet to be defined in such systems. We report here the use of perfusion culture and two powerful non-invasive techniques, magnetic resonance imaging (MRI) and spectroscopy (MRS), to characterize the flow profile inside a fixed bed bioreactor. the growth and energetics of the cells and the kinetics of ECM deposition. These techniques were used to correlate non-invasively the properties of the generated bioartificial meniscal cartilage with fluid dynamics and permeability measurements. An ideal flow rate for operation of the bioreactor (40 mlmin(-1)) was derived which optimises structural properties and ECM production.
引用
收藏
页码:571 / 573
页数:3
相关论文
共 50 条
  • [11] Tissue engineering of cartilage [Tissue engineering von Knorpelzellen]
    Hepp P.
    Bader A.
    Josten C.
    Rose T.
    Schulz R.
    Arthroskopie, 2005, 18 (3) : 233 - 238
  • [12] Surgical Therapy and Tissue Engineering for Meniscal Repair
    Wang, Hao
    Wu, Jie
    Yang, Liupu
    Liu, Shuyun
    Sui, Xiang
    Guo, Quanyi
    Chen, Mingxue
    TISSUE ENGINEERING PART B-REVIEWS, 2024,
  • [13] Injectable cartilage tissue engineering
    Elisseeff, J
    EXPERT OPINION ON BIOLOGICAL THERAPY, 2004, 4 (12) : 1849 - 1859
  • [14] Scaffolds for tissue engineering of cartilage
    Woodfield, TBF
    Bezemer, JM
    Pieper, JS
    van Blitterswijk, CA
    Riesle, J
    CRITICAL REVIEWS IN EUKARYOTIC GENE EXPRESSION, 2002, 12 (03): : 209 - 236
  • [15] Bioreactors for Tissue Engineering of Cartilage
    Concaro, S.
    Gustavson, F.
    Gatenholm, P.
    BIOREACTOR SYSTEMS FOR TISSUE ENGINEERING, 2009, 112 : 125 - 143
  • [17] BIOREACTOR FOR CARTILAGE TISSUE ENGINEERING
    Mikulenka, Petr
    Franta, Lukas
    Daniel, Matej
    25TH DANUBIA-ADRIA SYMPOSIUM ON ADVANCES IN EXPERIMENTAL MECHANICS, 2008, : 173 - 174
  • [18] Perspectives on cartilage tissue engineering
    Schneider, U
    AKTUELLE RHEUMATOLOGIE, 2003, 28 (06) : 322 - 327
  • [19] Biomechanics in cartilage tissue engineering
    Zhang C.
    Li K.
    Gao L.
    Zhang X.
    Advances in Mechanics, 2018, 48 (01) : 410 - 437
  • [20] Bone and cartilage tissue engineering
    Boyan, BD
    Lohmann, CH
    Romero, J
    Schwartz, Z
    CLINICS IN PLASTIC SURGERY, 1999, 26 (04) : 629 - +