APPLICATION ANALYSIS OF CHILLED WATER STORAGE TECHNOLOGY IN THE TRANSFORMATION OF CENTRAL AIR CONDITIONING SYSTEM

被引:0
|
作者
Liu, Kaijing [1 ]
Zhang, Qunli [1 ]
Li, Deying [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing, Peoples R China
关键词
central air conditioning chilled water storage technology; Analysis of the advantages and disadvantages; renovation project;
D O I
10.4028/www.scientific.net/AMR.608-609.1097
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article introduces the specific application of central air conditioning chilled water storage technology in the actual central air conditioning engineered reconstruction. The author analyzes the energy-saving effect of application of central air conditioning chilled water storage technology and the economy of central conditioning renovation project. Operation cost comparison shows that water storage air conditioning system saves money more above 35% than conventional air conditioning system.
引用
收藏
页码:1097 / 1105
页数:9
相关论文
共 50 条
  • [31] Study on a new optimum design method for the air-conditioning chilled water system
    Yin, P
    Jiang, CX
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1547 - 1554
  • [32] Effect of hybrid and single nanofluids on the performance characteristics of chilled water air conditioning system
    Ahmed, M. Salem
    Elsaid, Ashraf Mimi
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [34] Air conditioning system with dual-temperature chilled water for air grading treatment in data centers
    Wang, Wentao
    Liang, Chenjiyu
    Zha, Fuhai
    Wang, Huan
    Shi, Wenxing
    Cui, Zhiyong
    Zhang, Kaiqing
    Jia, Hunlin
    Li, Junjun
    Li, Xianting
    ENERGY AND BUILDINGS, 2023, 290
  • [35] The chilled water storage analysis for a university building cooling system
    Boonnasa, Somkiat
    Namprakai, Pichai
    APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) : 1396 - 1408
  • [36] Experimental study and analysis of the application of ice-storage capsules in an air conditioning system
    Ye, Shuiquan
    Ye, Zhaofa
    Zhu, Hua
    Feng, Toqing
    Zhang, Zhanwang
    Yuan, Hai
    Hu, Shing-Bun
    Heat Transfer - Asian Research, 2002, 31 (01): : 21 - 27
  • [37] Central chilled water system modeling
    Kirby, Nelson
    Engineered Systems, 2010, 27 (03):
  • [38] Comparison of energy performance and economics of chilled water thermal storage and conventional air-conditioning systems
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    ENERGY AND BUILDINGS, 2014, 69 : 237 - 250
  • [39] Energy saving analysis and application of secondary pump in air conditioning water system
    Guo, Gang
    Li, Ruo
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1235 - 1239
  • [40] A Group Control Method of Central Air-conditioning Chilled Water Pumps with the Aim of Energy Saving
    Li, Hai
    Shi, Jun
    Li, Ziwen
    Yang, Caidong
    Zhang, Yan
    Liang, Zhaowen
    Liu, Yongqiang
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 4517 - 4524