Evaluation of boron-doped diamond electrode for simultaneous voltammetric determination of hydrochlorothiazide and losartan in pharmaceutical formulations

被引:67
|
作者
Gardenal Santos, Michely Cristina [1 ]
Teixeira Tarley, Cesar Ricardo [1 ]
Dall'Antonia, Luiz Henrique [1 ]
Sartori, Elen Romao [1 ]
机构
[1] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, BR-86057970 Londrina, PR, Brazil
来源
关键词
Hydrochlorothiazide determination; Losartan determination; BDD electrode; Anodic pretreatment; Voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; CARBON-PASTE ELECTRODE; ELECTROCHEMICAL-BEHAVIOR; POTASSIUM; FILM; ACID; VALIDATION; NANOTUBES; TABLETS; SENSOR;
D O I
10.1016/j.snb.2013.07.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the simultaneous determination of hydrochlorothiazide (HCTZ) and losartan (LOS) in pharmaceutical formulations using differential-pulse voltammetry (DPV) was developed. Two very wellresolved and reproducible oxidation peaks of HCTZ and LOS, with separation of 0.23 V, were obtained in Britton-Robinson (BR) buffer (pH 9.5) using an anodically pretreated boron-doped diamond electrode. Under the optimum analytical experimental conditions, the voltammetric method exhibited linear responses for simultaneous determination of HCTZ and LOS in the concentration range 3.0 x 10(-6) to 7.4 x 10(-5) mol L-1 for both compounds, with detection limits of 1.2 x 10(-6) mol L-1 and 9.5 x 10(-7) MOI respectively. The proposed method was successfully applied in the simultaneous determination of LOS and HCTZ content in pharmaceutical formulations, whose accuracy was attested by good agreement of the results (paired t-test at a 95% confidence level) with those obtained using high performance liquid chromatography (HPLC). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [31] VOLTAMMETRIC DETERMINATION OF AMITRIPTYLINE IN PHARMACEUTICAL FORMULATION WITH BORON-DOPED DIAMOND ELECTRODE EXPLOITING MEASURES IN ACID MEDIUM
    Duarte, Eduardo Henrique
    Gorla, Felipe Augusto
    Sartori, Elen Romao
    Teixeira Tarley, Cesar Ricardo
    QUIMICA NOVA, 2014, 37 (09): : 1496 - 1502
  • [32] Voltammetric behavior of rutin at a boron-doped diamond electrode. Its electroanalytical determination in a pharmaceutical formulation
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (10): : 1674 - 1681
  • [33] Simultaneous Determination of Caffeine and Acetylsalicylic Acid in Pharmaceutical Formulations Using a Boron-Doped Diamond Film Electrode by Differential Pulse Voltammetry
    Faria, Eric Oliveira
    Viera Lopes Junior, Antonio Carlos
    Pires Souto, Denio Emanuel
    Figueiredo Leite, Fernando Roberto
    Damos, Flavio Santos
    Silva Luz, Rita de Cassia
    dos Santos, Alexandre Soares
    Franco, Diego Leoni
    Pio dos Santos, Wallans Torres
    ELECTROANALYSIS, 2012, 24 (05) : 1141 - 1146
  • [34] The Performance of Boron-Doped Diamond Electrode for the Determination of Ramipril and its Association with Hydrochlorothiazide
    Mattos, Gabriel Junquetti
    Scremin, Jessica
    Rossi Salamanca-Neto, Carlos Alberto
    Sartori, Elen Romao
    ELECTROANALYSIS, 2017, 29 (04) : 1180 - 1187
  • [35] Multivariate approach in voltammetric identification and simultaneous determination of eugenol, carvacrol, and thymol on boron-doped diamond electrode
    Kowalcze, Mateusz
    Jakubowska, Matgorzata
    MONATSHEFTE FUR CHEMIE, 2019, 150 (06): : 991 - 1002
  • [36] Multivariate approach in voltammetric identification and simultaneous determination of eugenol, carvacrol, and thymol on boron-doped diamond electrode
    Mateusz Kowalcze
    Małgorzata Jakubowska
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 991 - 1002
  • [37] Simultaneous voltammetric determination of synthetic colorants in food using a cathodically pretreated boron-doped diamond electrode
    Medeiros, Roberta A.
    Lourencao, Bruna C.
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2012, 97 : 291 - 297
  • [38] Simultaneous square-wave voltammetric determination of aspartame and cyclamate using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2008, 76 (03) : 685 - 689
  • [39] Voltammetric quantification of the anesthetic drug propofol (2,6-diisopropylphenol) in pharmaceutical formulations on a boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Ozok, Hande Izem
    Yunusoglu, Oruc
    Yardim, Yavuz
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2021, 86 (7-8) : 711 - 724
  • [40] Analytical determination of aliskiren in pharmaceutical formulations using boron-doped diamond electrodes
    Carvalho, Flavio H. O.
    Cintra, Alessandra
    Abrahao, Odonirio
    Gomes, Roseli A. S.
    Salazar-Banda, Giancarlo R.
    Oliveira, Robson T. S.
    ANALYTICAL METHODS, 2015, 7 (18) : 7461 - 7466