Visual and multiplex detection of nucleic acid sequence by multiple cross displacement amplification coupled with gold nanoparticle-based lateral flow biosensor

被引:28
|
作者
Wang, Yi [1 ]
Wang, Yan [1 ]
Zhang, Lu [1 ]
Xu, Jianguo [1 ]
Ye, Changyun [1 ]
机构
[1] Chinese Ctr Dis Control & Prevent, Collaborat Innovat Ctr Diag & Treatment Infect Di, State Key Lab Infect Dis Prevent & Control, Natl Inst Communicable Dis Control & Prevent, Beijing 102206, Peoples R China
关键词
MCDA; LFB; MCDA-LFB; LoD; Salmonella spp; Shigella spp; ISOTHERMAL-AMPLIFICATION; SALMONELLA; DIAGNOSIS; FAMILY; PCR;
D O I
10.1016/j.snb.2016.10.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, we reported on the establishment of a nearly instrument free, simple and rapid molecular technique, which incorporated multiple cross displacement amplification coupled with lateral flow biosensor (MCDA-LFB) for the visual, sensitive and specific detection of nucleic acid sequence. The MCDA-LFB assay was able to simultaneously detect and correctly differentiate multiple targets using a 40 min amplification reaction followed by a 2 min incubation of the products on the visualization biosensor. The biosensor was devised to detect three targets, a chromatography control, the MCDA target amplicon I and II, and the interpretation of test results is based on the appearance of red lines on the reaction pad. As a proof of concept, Shigella and Salmonella strains were detected by MCDA-LFB technique to demonstrate the availability of target analysis. The analytical sensitivity, specificity and practical application of MCDA-LFB assay were successfully evaluated in pure culture and blood samples, and the whole procedure, including specimen (blood sample) processing (35 min), isothermal reaction (40 min), and result reporting (5 min), was completed within 80 min. Therefore, the simplicity, rapidity and nearly apparatus-free platform of the MCDA-LFB assay make it practical for point-of-care testing, field detection, 'on-site' diagnosis and more. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:1283 / 1293
页数:11
相关论文
共 50 条
  • [31] Visual detection of microRNA with lateral flow nucleic acid biosensor
    Gao, Xuefei
    Xu, Hui
    Baloda, Meenu
    Gurung, Anant S.
    Xu, Li-Ping
    Wang, Tao
    Zhang, Xueji
    Liu, Guodong
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 578 - 584
  • [32] Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection
    Wang, Yacui
    Wang, Yi
    Jiao, Weiwei
    Li, Jieqiong
    Quan, Shuting
    Sun, Lin
    Wang, Yonghong
    Qi, Xue
    Wang, Xingyun
    Shen, Adong
    AMB EXPRESS, 2019, 9 (01)
  • [33] Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection
    Yacui Wang
    Yi Wang
    Weiwei Jiao
    Jieqiong Li
    Shuting Quan
    Lin Sun
    Yonghong Wang
    Xue Qi
    Xingyun Wang
    Adong Shen
    AMB Express, 9
  • [34] Ultrasensitive detection of DNA sequence using fluorescent carbon nanoparticle-based lateral flow biosensor
    Takalkar, Sunitha
    Liu, Guodong
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [35] Multiple cross displacement amplification-based lateral flow biosensor for rapid and sensitive detection of Helicobacter pylori
    Chen, Yanfei
    Zhou, Juan
    Wang, Jiao
    He, Xi
    Huang, Xiaolan
    Xiao, Fei
    Jia, Nan
    Wang, Yi
    Zhong, Xuemei
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2024, 14
  • [36] Highly sensitive and rapid identification of coxsackievirus A16 based on reverse transcription multiple cross displacement amplification combined with nanoparticle-based lateral flow biosensor assay
    Cheng, Jinzhi
    Wang, Yu
    Zhou, Yuhong
    Lu, Jingrun
    Tang, Xiaomin
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [37] Development of multiplex cross displacement amplification combined with lateral flow biosensor assay for detection of virulent shigella sonnei
    Wang, Yonglu
    He, Ziqiang
    Ablimit, Patigul
    Ji, Shunshi
    Jin, Dong
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [38] Visual detection of nucleic acids based on lateral flow biosensor and hybridization chain reaction amplification
    Ying, Na
    Ju, Chuanjing
    Li, Zhongyi
    Liu, Wensen
    Wan, Jiayu
    TALANTA, 2017, 164 : 432 - 438
  • [39] Rapid and Visual Differentiation of Mycobacterium tuberculosis From the Mycobacterium tuberculosis Complex Using Multiplex Loop-Mediated Isothermal Amplification Coupled With a Nanoparticle-Based Lateral Flow Biosensor
    Yang, Xinggui
    Huang, Junfei
    Chen, Xu
    Xiao, Ziyu
    Wang, Xiaojuan
    Chen, Yijiang
    Zheng, Wenlin
    Chen, Wei
    Chen, Huijuan
    Lei, Shiguang
    Hu, Yong
    Li, Shijun
    FRONTIERS IN MICROBIOLOGY, 2021, 12
  • [40] Rapid and Sensitive Isothermal Detection of Nucleic-acid Sequence by Multiple Cross Displacement Amplification
    Wang, Yi
    Wang, Yan
    Ma, Ai-Jing
    Li, Dong-Xun
    Luo, Li-Juan
    Liu, Dong-Xin
    Jin, Dong
    Liu, Kai
    Ye, Chang-Yun
    SCIENTIFIC REPORTS, 2015, 5