A Biomechanical Evaluation of All-Inside 2-Stitch Meniscal Repair Devices With Matched Inside-Out Suture Repair

被引:17
|
作者
Ramappa, Arun J. [1 ]
Chen, Alvin [1 ]
Hertz, Benjamin [1 ]
Wexler, Michael [1 ]
Bournissaint, Leandro Grimaldi [1 ]
DeAngelis, Joseph P. [1 ]
Nazarian, Ara [1 ]
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Ctr Adv Orthopaed Studies, Dept Orthopaed Surg,Sch Med, Boston, MA 02215 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2014年 / 42卷 / 01期
关键词
meniscal repair; all inside; inside out; initial displacement; biomechanics; 2-stitch repair; WEIGHT POLYETHYLENE SUTURE; HORIZONTAL SUTURE; IN-VITRO; STRENGTH; SYSTEM; ARROW;
D O I
10.1177/0363546513505190
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. Purpose: To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. Study Design: Controlled laboratory study. Methods: Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. Results: The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. Conclusion: With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. Clinical Relevance: The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [21] All-inside, suture anchor repair for meniscal root tears
    Gregory Scott DiFelice
    Hilary Umans
    Eliyahu Englesohn
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 428 - 429
  • [22] All-inside, suture anchor repair for meniscal root tears
    Nam-Hong Choi
    Kyoung-Mo Son
    Brian N. Victoroff
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 430 - 430
  • [23] All-inside, suture anchor repair for meniscal root tears
    Choi, Nam-Hong
    Son, Kyoung-Mo
    Victoroff, Brian N.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) : 430 - 430
  • [24] The evolution of all-inside meniscal repair
    Diduch, DR
    Poelstra, KA
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (02) : 83 - 90
  • [25] All-inside Meniscal Repair System
    Becker, R.
    ARTHROSKOPIE, 2006, 19 (01) : 88 - 88
  • [26] Comparative Outcomes of All-Inside Versus Inside-Out Repair of Bucket-Handle Meniscal Tears: A Propensity-Matched Analysis
    Samuelsen, Brian T.
    Johnson, Nicholas R.
    Hevesi, Mario
    Levy, Bruce A.
    Dahm, Diane L.
    Stuart, Michael J.
    Krych, Aaron J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (06):
  • [27] Editorial Commentary: Feeling the Pressure! A Biomechanical Analysis of All-Inside and Inside-Out Knee Meniscus Repair
    Barber, F. Alan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (10): : 1849 - 1851
  • [28] Primary Fixation and Cyclic Performance of Single-Stitch All-Inside and Inside-Out Meniscal Devices for Repairing Vertical Longitudinal Meniscal Tears
    Bachmaier, Samuel
    Krych, Aaron J.
    Smith, Patrick A.
    Herbort, Mirco
    Ritter, Daniel
    LaPrade, Robert F.
    Wijdicks, Coen A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (10): : 2705 - 2713
  • [29] Continuous Vertical Inside-Out Versus Traditional Vertical Inside-Out Meniscal Repair: A Biomechanical Comparison
    de Faria, Jose Leonardo Rocha
    Santos, Arthur Paiva Grimaldi
    Pavao, Douglas Mello
    Radulski, Mariana
    Leal, Ana Carolina
    More, Ari Digiacomo Ocampo
    de Paula Mozella, Alan
    Guimaraes, Joao Antonio Matheus
    LaPrade, Robert F.
    de Mello Roesler, Carlos Rodrigo
    Salim, Rodrigo
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (11)
  • [30] All-inside versus inside-out suture techniques in arthroscopic meniscus repair A prospective randomized study protocol
    Lin, Yanming
    Zhao, Jiasong
    Qiu, Heng
    Huang, Yong
    MEDICINE, 2020, 99 (27) : E20688