Minimally Invasive Versus Conventional Dynamic Hip Screw for the Treatment of Intertrochanteric Fractures in Older Patients

被引:14
|
作者
Zhou, Zhiping [1 ]
Zhang, Xingxiang [1 ]
Tian, Shoujin [1 ]
Wu, Yaogang [1 ]
机构
[1] Zhangjiagang First Pepoles Hosp, Dept Orthoped Surg, Zhangjiagang 215600, Jiangsu, Peoples R China
关键词
METAANALYSIS; FIXATION; PLATE; TRIAL; CARE;
D O I
10.3928/01477447-20120123-42
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare minimally invasive and conventional dynamic hip screw techniques for the treatment of intertrochanteric fractures in older patients. Relevant randomized, controlled studies were included. The methodological quality was assessed, and data were extracted independently. Five studies (353 fractures) that compared minimally invasive and conventional dynamic hip screw techniques were included. The rates of serious postoperative complications, operative time (minutes), hemoglobin decrease (g/dL), postoperative Harris Hip Scores, and length of stay (days) were the outcomes of interest. A lower rate of serious postoperative complications was correlated with the minimally invasive dynamic hip screw group compared with the conventional dynamic hip screw group (relative risk, 0.35; 95% confidence interval [CI], 0.16, 0.78), average operative time (weighted mean difference, -16.32; 95% CI, -28.78 to -3.86), hemoglobin decrease (weighted mean difference, -1.44; 95% CI, -1.98 to -0.89), and length of stay (weighted mean difference, -3.72; 95% CI, -5.44 to -2.01) were lower in the minimally invasive dynamic hip screw group, and the postoperative Harris Hip Score (weighted mean difference, 1.42; 95% CI, 0.23 to 2.60) was higher in the minimally invasive dynamic hip screw group.
引用
收藏
页码:E244 / E249
页数:6
相关论文
共 50 条
  • [41] Cephalomedullary nail versus sliding hip screw for unstable intertrochanteric fractures in elderly patients
    Chua, Ivan Tjun Huat
    Rajamoney, Ganesan Naidu
    Kwek, Ernest Beng Kee
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 308 - 312
  • [42] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Upadhyay, Sachin
    Raza, H. K. T.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 130 - 131
  • [43] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Dhamangaonkar, Anoop C.
    Joshi, Deepak
    Goregaonkar, Arvind B.
    Tawari, Akhil A.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 317 - 322
  • [44] Delay Fixation of Trochanteric Fractures Using Dynamic Hip Screw: A Minimally Invasive Technique
    Mahaisavariya, Banchong
    Riansuwan, Kongkhet
    TECHNIQUES IN ORTHOPAEDICS, 2006, 21 (02) : 109 - 114
  • [45] Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    OBrien, PJ
    Meek, RN
    Blachut, PA
    Broekhuyse, HM
    Sabharwal, S
    CANADIAN JOURNAL OF SURGERY, 1995, 38 (06) : 516 - 520
  • [46] Sliding hip screw versus sliding helical blade for intertrochanteric fractures
    Fang, C.
    Lau, T. W.
    Wong, T. M.
    Lee, H. L.
    Leung, F.
    BONE & JOINT JOURNAL, 2015, 97B (03): : 398 - 404
  • [47] Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
    C. C. Wu
    C. H. Shih
    W. J. Chen
    C. L. Tai
    Archives of Orthopaedic and Trauma Surgery, 1998, 117 : 193 - 196
  • [48] Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
    Wu, CC
    Shih, CH
    Chen, WJ
    Tai, CL
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (4-5) : 193 - 196
  • [49] Minimally Invasive Dynamic Hip Screw (MIDHS) Fixation
    Rijal, Laxman
    Sagar, Gopal
    Ansari, Tahir
    Kumar, Ramakant
    Rao, Sukesh
    Kancherla, Ramprasad
    TECHNIQUES IN ORTHOPAEDICS, 2014, 29 (04) : 237 - 241
  • [50] Dynamic Hip Screw Compared to Condylar Blade Plate in the Treatment of Unstable Fragility Intertrochanteric Fractures
    Yong, C. K.
    Tan, C. N.
    Penafort, R.
    Singh, D. A.
    Varaprasad, M. V.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2009, 3 (01) : 13 - 18