Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures

被引:23
|
作者
Yang, Yang [1 ]
Fu, Renzhong [1 ]
Yuan, Jianjun [1 ]
Wu, Shiyuan [1 ]
Zhang, Jialiang [1 ]
Wang, Haiying [1 ]
机构
[1] Changshu Inst Technol, Dept Chem, Jiangsu Lab Adv Funct Mat, Changshu 215500, Peoples R China
基金
中国国家自然科学基金;
关键词
Platinum nanoparticles; Heterostructure; Carbon nanofiber; H2O2; sensor; Hydrogen peroxide; GLUCOSE; COMPOSITE; POLYACRYLONITRILE; PERFORMANCE; BIOSENSOR; ELECTROCATALYST; FABRICATION; CATALYST; H2O2;
D O I
10.1007/s00604-015-1558-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are presenting a sensor for hydrogen peroxide (H2O2) that is based on the use of a heterostructure composed of Pt nanoparticles (NPs) and carbon nanofibers (CNFs). High-density Pt NPs were homogeneously loaded onto a three-dimensional nanostructured CNF matrix and then deposited in a glassy carbon electrode (GCE). The resulting sensor synergizes the advantages of the conducting CNFs and the nanoparticle catalyst. The porous structure of the CNFs also favor the high-density immobilization of the NPs and the diffusion of water-soluble molecules, and thus assists the rapid catalytic oxidation of H2O2. If operated at a working voltage of -0.2 V (vs. Ag/AgCl), the modified GCE exhibits a linear response to H2O2 in the 5 mu M to 15 mM concentration range (total analytical range: 5 mu M to 100 mM), with a detection limit of 1.7 mu M (at a signal-to-noise ratio of 3). The modified GCE is not interfered by species such as uric acid and glucose. Its good stability, high selectivity and good reproducibility make this electrode a valuable tool for inexpensive amperometric sensing of H2O2.
引用
收藏
页码:2241 / 2249
页数:9
相关论文
共 50 条
  • [41] A sensitive and selective nitrite sensor based on a glassy carbon electrode modified with gold nanoparticles and sulfonated graphene
    Li, Su-Juan
    Zhao, Guo-Yan
    Zhang, Rong-Xia
    Hou, Ya-Li
    Liu, Lin
    Pang, Huan
    MICROCHIMICA ACTA, 2013, 180 (9-10) : 821 - 827
  • [42] Analytical sensing of hydrogen peroxide on Ag nanoparticles–multiwalled carbon nanotube-modified glassy carbon electrode
    Ahmadreza Afraz
    Amir Abbas Rafati
    Ali Hajian
    Journal of Solid State Electrochemistry, 2013, 17 : 2017 - 2025
  • [43] A highly sensitive electrochemical sensor based on gold nanoparticles/multiwall carbon nanotubes-modified glassy carbon electrode for selective determination of traces of atenolol
    Shamsipur, Mojtaba
    Saber, Reza
    Emami, Mandi
    ANALYTICAL METHODS, 2014, 6 (17) : 7038 - 7045
  • [44] The electrodeposition of Ag nanoparticles on a type I collagen-modified glassy carbon electrode and their applications as a hydrogen peroxide sensor
    Song, Yonghai
    Cui, Kang
    Wang, Li
    Chen, Shouhui
    NANOTECHNOLOGY, 2009, 20 (10)
  • [45] Electrocatalytic Oxidation of Hydrogen Peroxide and Cysteine at a Glassy Carbon Electrode Modified with Platinum Nanoparticle-deposited Carbon Nanotubes
    Jianping Li
    Qiaoling Yu
    Tuzhi Peng
    Analytical Sciences, 2005, 21 : 377 - 381
  • [46] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Zhang, Yuanyuan
    Duan, Yulin
    Shao, Zeyu
    Chen, Chen
    Yang, Mei
    Lu, Guodong
    Xu, Wenfeng
    Liao, Xiaoling
    MICROCHIMICA ACTA, 2019, 186 (06)
  • [47] Electrocatalytic oxidation of hydrogen peroxide and cysteine at a glassy carbon electrode modified with platinum nanoparticle-deposited carbon nanotubes
    Li, JP
    Yu, QL
    Peng, TZ
    ANALYTICAL SCIENCES, 2005, 21 (04) : 377 - 381
  • [48] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Yuanyuan Zhang
    Yulin Duan
    Zeyu Shao
    Chen Chen
    Mei Yang
    Guodong Lu
    Wenfeng Xu
    Xiaoling Liao
    Microchimica Acta, 2019, 186
  • [49] Hydrogen peroxide sensor based on riboflavin immobilized at the nickel oxide nanoparticle-modified glassy carbon electrode
    Roushani, Mahmoud
    Abdi, Zeinab
    Daneshfar, Ali
    Salimi, Abdollah
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2013, 43 (12) : 1175 - 1183
  • [50] Hydrogen peroxide sensor based on riboflavin immobilized at the nickel oxide nanoparticle-modified glassy carbon electrode
    Mahmoud Roushani
    Zeinab Abdi
    Ali Daneshfar
    Abdollah Salimi
    Journal of Applied Electrochemistry, 2013, 43 : 1175 - 1183