Rapid measurement of S-100B serum protein levels by Elecsys S100 immunoassay in patients undergoing carotid artery stenting or endarterectomy

被引:21
|
作者
Mussack, T
Klauss, V
Ruppert, V
Gippner-Steppert, C
Biberthaler, P
Schiemann, U
Hoffmann, U
Jochum, M
机构
[1] Univ Munich, Klinikum Innenstadt, Dept Surg, D-80336 Munich, Germany
[2] Univ Munich, Klinikum Innenstadt, Dept Internal Med, D-80336 Munich, Germany
[3] Univ Munich, Klinikum Innenstadt, Dept Clin Chem & Clin Biochem, D-80336 Munich, Germany
[4] Inselspital Bern, Dept Internal Med, CH-3010 Bern, Switzerland
关键词
angioplasty; carotid arteries; carotid stenting; carotid endarterectomy; cerebral ischemia; cerebrovascular disorders; Elecsys S100;
D O I
10.1016/j.clinbiochem.2005.12.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: This study was designed to apply the rapid Elecsys (R) S 100 irnrnunoassay for real-time measurement of S100 protein serum levels indicating acute brain damage in patients undergoing carotid artery stenting (CAS) or endarterectomy (CEA). Design and methods: Data of 14 CAS patients were compared to those of 43 CEA and 14 control patients undergoing coronary angiography (CA). S100 serum levels were measured by the full-automatic Elecsys (R) S100 immunoassay and compared to those obtained by the well-established LIA-mat (R) S100 system. Results: In contrast to CAS and CA patients, median S100 serum levels of CEA patients significantly increased to 0.24 ng/mL before declamping, but subsequently returned to baseline. Three CEA patients with neurological deficits showed sustained elevated S 100 levels 6 h after extubation. Absolute S100 values were not significantly different between the two methods. Bland-Altman plot analyses displayed a good agreement, mostly indicating slightly smaller Values applying the Elecsys (R) S100 system. Conclusions: The Elecsys (R) S100 system appears to be suitable for rapid real-time detection of neurological deficits in patients undergoing CAS and CEA. Persistent elevations of Elecsys (R) S100 levels during CEA were associated with prolonged neurological disorders, whereas transient increases seem to represent impaired blood-brain barrier integrity without neurological deficits. (c) 2006 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 50 条
  • [21] Assessment of Early Brain Damage in Carotid Endarterectomy: Evaluation of S-100B Serum Levels and Somatosensory Evoked Potentials in a Pilot Study
    Thomas Mussack
    Peter Biberthaler
    Thomas Geisenberger
    Cornelia Gippner-Steppert
    Bernd Steckmeier
    Wolf Mutschler
    Marianne Jochum
    World Journal of Surgery, 2002, 26 : 1251 - 1255
  • [22] Protein S-100b serum levels in trauma-induced brain death
    Dimopoulou, I
    Korfias, S
    Dafni, U
    Anthi, A
    Psachoulia, C
    Jullien, G
    Sakas, DE
    Roussos, C
    NEUROLOGY, 2003, 60 (06) : 947 - 951
  • [23] Isolated vertebral fractures give elevated serum protein S-100B levels
    Benneker, Lorin M.
    Leitner, Christoph
    Martinolli, Luca
    Robert, Kretschmer
    Zimmermann, Heinz
    Exadaktylos, Aristomenis K.
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2008, 16 (1):
  • [24] Serum S-100B protein in severe head injury
    Woertgen, C
    Rothoerl, RD
    NEUROSURGERY, 2000, 46 (04) : 1026 - 1027
  • [25] Isolated vertebral fractures give elevated serum protein S-100B levels
    Lorin M Benneker
    Christoph Leitner
    Luca Martinolli
    Kretschmer Robert
    Heinz Zimmermann
    Aristomenis K Exadaktylos
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 16
  • [26] Serum glial fibrillary acidic protein and S100 calcium-binding protein B correlates cerebral vessel reactivity following carotid artery stenting
    Yuan, Xiaofan
    Guo, Lei
    Wang, Jianhong
    Wang, Duozi
    Yang, Shu
    Guo, Fuqiang
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [27] Serum glial fibrillary acidic protein and S100 calcium-binding protein B correlates cerebral vessel reactivity following carotid artery stenting
    Xiaofan Yuan
    Lei Guo
    Jianhong Wang
    Duozi Wang
    Shu Yang
    Fuqiang Guo
    Scientific Reports, 11
  • [28] Serum S-100b protein as a biomarker for the assessment of neuroprotectants
    Shirasaki, Y
    Edo, N
    Sato, T
    BRAIN RESEARCH, 2004, 1021 (02) : 159 - 166
  • [29] Assessment of early brain damage in carotid endarterectomy: Evaluation of S-100B serum levels and somatosensory evoked potentials in a pilot study
    Mussack, T
    Biberthaler, P
    Geisenberger, T
    Gippner-Steppert, C
    Steckmeier, B
    Mutschler, W
    Jochum, M
    WORLD JOURNAL OF SURGERY, 2002, 26 (10) : 1251 - 1255
  • [30] Multicenter evaluation of the analytical and clinical performance of the Elecsys® S100 immunoassay in patients with malignant melanoma
    Alber, B
    Hein, R
    Garbe, C
    Caroli, U
    Luppa, PB
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (05) : 557 - 563