Septal function during left ventricular unloading

被引:2
|
作者
Moon, MR
Bolger, AF
DeAnda, A
Komeda, M
Daughters, GT
Nikolic, SD
Miller, DC
Ingels, NB
机构
[1] STANFORD UNIV,SCH MED,DEPT CARDIOVASC & THORAC SURG,STANFORD,CA 94305
[2] STANFORD UNIV,SCH MED,DIV CARDIOVASC MED,STANFORD,CA 94305
[3] PALO ALTO MED FDN,RES INST,PALO ALTO,CA 94301
[4] DEPT VET AFFAIRS MED CTR,CARDIAC SURG SECT,PALO ALTO,CA
[5] DEPT VET AFFAIRS MED CTR,CARDIOL SECT,PALO ALTO,CA
关键词
echocardiography; heart-assist device; ventricles; mechanics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Left ventricular (LV) unloading with mechanical support devices alters biventricular geometry and impairs right ventricular (RV) contractility, but its effect on septal systolic function remains unknown. Methods and Results To evaluate the effects of LV volume and pressure unloading on septal geometry and function, LV preload was abruptly reduced by clamping left atrial pressure between 0 and -2 mm Hg in seven open-chest, anesthetized dogs by use of a pressure-control servomechanism to withdraw blood from the left atrium. With left atrial pressure clamping, maximal LV pressure decreased 30+/-12% (mean+/-SD) (P<.0001) and LV end-diastolic cross-sectional area (determined by two-dimensional echocardiography) decreased by 53+/-16% (P<.0001). This caused the septum to shift toward the left (RV septal free-wall dimension increased; P<.004) and flatten (radius of curvature increased; P<.0002), while LV septal free-wall dimension fell (P<.0001). Septal end-diastolic thickness increased 23+/-15% (P<.0005), reflecting a decline in septal preload. Systolic septal thickening decreased (P<.002), while systolic septal output (Septal Output=Septal ThickeningXHeart Rate) fell from 30+/-17 to 15+/-22 cm/min (P<.002). This was associated with movement along the septal Frank-Starling equivalent (septal output versus end-diastolic septal thickness [preload] relation) to a less productive portion of the curve. Conclusions LV unloading not only altered interventricular septal geometry but also reduced septal systolic thickening and output, all of which may contribute to impaired RV contractility during mechanical LV support.
引用
收藏
页码:1320 / 1327
页数:8
相关论文
共 50 条
  • [31] VENTRICULAR MOTION AND FUNCTION DURING SEPTAL ISCHEMIA IN DOGS
    OBARA, A
    YAMASHITA, H
    IMAMOTO, T
    TAKASHIO, T
    TANAZAWA, S
    INOUE, H
    KAWAMURA, Y
    HASEBE, N
    MORIMOTO, H
    KATO, J
    ONODERA, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (07): : 772 - 772
  • [32] Right ventricular apical versus septal pacing: impact on left ventricular synchrony and function
    I Atteia
    A Alazab
    K Hussein
    N Abeed
    H Nagi
    Critical Care, 16 (Suppl 1):
  • [33] Effects of septal myectomy on left atrial and left ventricular function in obstructive hypertrophic cardiomyopathy
    Ha, Kyung Eun
    Choi, Kang-Un
    Lee, Hee-Jung
    Gwak, Seo-Yeon
    Kim, Kyu
    Cho, Iksung
    Hong, Geu-Ru
    Ha, Jong-Won
    Shim, Chi Young
    ESC HEART FAILURE, 2023, 10 (05): : 2939 - 2947
  • [34] LEFT-VENTRICULAR FUNCTION FOLLOWING VENTRICULAR SEPTAL-DEFECT CLOSURE IN INFANCY
    CORDELL, GD
    GRAHAM, TP
    ATWOOD, GF
    BOERTH, RC
    BENDER, HW
    CIRCULATION, 1975, 52 (04) : 9 - 9
  • [35] Left ventricular unloading during veno-arterial ECMO: a review of percutaneous and surgical unloading interventions
    Donker, Dirk W.
    Brodie, Daniel
    Henriques, Jose P. S.
    Broome, Michael
    PERFUSION-UK, 2019, 34 (02): : 98 - 105
  • [36] Left ventricular septal aneurysm
    Dipchand, AI
    Boutin, C
    CIRCULATION, 1998, 98 (16) : 1697 - 1697
  • [37] Left ventricular septal lipoma
    Munoz Garcia, Ricardo
    Ruiz Alonso, Enrique
    Vera Puente, Francisco
    Ianez Ramirez, Aida
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (12) : 791 - 792
  • [38] ATRIAL SEPTAL-DEFECT BLUNTS THE IMPAIRMENT OF LEFT-VENTRICULAR FUNCTION DURING THE MUELLER MANEUVER
    VIROLAINEN, J
    VENTILA, M
    KUPARI, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (04) : 1999 - 2004
  • [39] INTERVENTRICULAR SEPTAL MOTION AND LEFT-VENTRICULAR FUNCTION IN PATIENTS WITH ATRIAL SEPTAL-DEFECT
    VINCENT, RN
    SAURETTE, RH
    PELECH, AN
    COLLINS, GF
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : B68 - B68
  • [40] INTERVENTRICULAR SEPTAL MOTION AND LEFT-VENTRICULAR FUNCTION IN PATIENTS WITH ATRIAL SEPTAL-DEFECT
    VINCENT, RN
    SAURETTE, RH
    PELECH, AN
    COLLINS, GF
    PEDIATRIC CARDIOLOGY, 1988, 9 (03) : 143 - 148