Oxygen insensitive amperometric glucose biosensor based on FAD dependent glucose dehydrogenase co-entrapped with DCPIP or DCNQ in a polydopamine layer

被引:14
|
作者
Cohen, Roy [1 ]
Cohen, Yifat [1 ]
Mukha, Dina [1 ]
Yehezkeli, Omer [1 ,2 ]
机构
[1] Technion Israel Inst Technol, Fac Biotechnol & Food Engn, David Rose Ave, IL-3200003 Haifa, Israel
[2] Technion Israel Inst Technol, Russell Berrie Nanotechnol Inst, IL-3200003 Haifa, Israel
关键词
Glucose sensing; FAD-GDH; MWCNTs; Redox mediator; Polydopamine; Nano-bio interface; DIRECT-ELECTRON-TRANSFER; CARBON NANOTUBE ELECTRODES; CELLOBIOSE DEHYDROGENASE; BURKHOLDERIA-CEPACIA; OXIDASE; ENZYME; IMMOBILIZATION; RECONSTITUTION; EXPRESSION; SYSTEMS;
D O I
10.1016/j.electacta.2020.137477
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Continuous glucose monitoring devices (CGM) are the present and the future for the challenging task of diabetes management. With a yearly increase of patients worldwide, glucose biosensors with high accuracy and low interference effect become crucial and should be developed. Here we show the development of an oxygen insensitive glucose biosensor which comprises FAD-dependent glucose dehydrogenase, dichlorophenol indophenol (DCPIP) or 2,3-dichloro-naphthoquinone (DCNQ) as redox mediators and polydopamine as a constraining layer. The sensors were fully characterized and the effect of interferences on glucose-sensing was analyzed. We further show long term bioelectrocatalytic activity for at least 3 days without any additional coating or treatment. The system shows great reproducibility via an easy fabrication methodology that should allow low-cost manufacturing. Those encouraging results show great promise for future sensor development of enzyme-based bioelectronics devices. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase
    Graca, J. S.
    de Oliveira, R. F.
    de Moraes, M. L.
    Ferreira, M.
    BIOELECTROCHEMISTRY, 2014, 96 : 37 - 42
  • [22] Hydrogen peroxide produced by glucose oxidase affects the performance of laccase cathodes in glucose/oxygen fuel cells: FAD-dependent glucose dehydrogenase as a replacement
    Milton, Ross D.
    Giroud, Fabien
    Thumser, Alfred E.
    Minteer, Shelley D.
    Slade, Robert C. T.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (44) : 19371 - 19379
  • [23] Reagentless amperometric glucose dehydrogenase biosensor based on electrocatalytic oxidation of NADH by osmium phenanthrolinedione mediator
    Hedenmo, M
    Narvaez, A
    Dominguez, E
    Katakis, I
    ANALYST, 1996, 121 (12) : 1891 - 1895
  • [24] Amperometric glucose biosensor with remarkable acid stability based on glucose oxidase entrapped in colloidal gold-modified carbon ionic liquid electrode
    Liu, Xiaoying
    Zeng, Xiandong
    Mai, Nannan
    Liu, Yong
    Kong, Bo
    Li, Yonghong
    Wei, Wanzhi
    Luo, Shenglian
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (12): : 2675 - 2679
  • [25] A novel amperometric glucose biosensor based on reconstitution of glucose oxidase on thiophene-3-boronic acid polymer layer
    Senel, Mehmet
    Dervisevic, Muamer
    Cevik, Emre
    CURRENT APPLIED PHYSICS, 2013, 13 (07) : 1199 - 1204
  • [26] Chromium hexacyanoferrate modified biosensor based on PQQ-dependent glucose dehydrogenase
    Tseng, Ta-Feng
    Yang, Yang-Li
    Lou, Shyh-Liang
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2681 - 2684
  • [27] An oxygen-insensitive reagentless glucose biosensor based on osmium-complex modified polypyrrole
    Habermüller, K
    Ramanavicius, A
    Laurinavicius, V
    Schuhmann, W
    ELECTROANALYSIS, 2000, 12 (17) : 1383 - 1389
  • [28] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 838 - 844
  • [29] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Liu, HY
    Li, HH
    Ying, TL
    Sun, K
    Qin, YQ
    Qi, DY
    ANALYTICA CHIMICA ACTA, 1998, 358 (02) : 137 - 144
  • [30] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Department of Chemistry and Chemical Engineering, Shanghai University, Shanghai
    200072, China
    不详
    Zhejiang Province
    310016, China
    Analytica Chimica Acta, 1999, 358 (02): : 137 - 144