Volar locking plates versus Kirschner wires for distal radial fractures-A cost analysis study

被引:53
|
作者
Shyamalan, Gunaratnam [1 ]
Theokli, Chris [1 ]
Pearse, Yemi [1 ]
Tennent, Duncan [1 ]
机构
[1] St George Hosp, Dept Orthopaed, London SW17 0QT, England
关键词
Distal radius fractures; Dorsal angulated fractures; K-wires; Volar locking plates; NHS tariffs; Extra-articular distal fractures; Buttress plate; Hand innovations; DVR plate; MANAGEMENT;
D O I
10.1016/j.injury.2009.02.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: There is an increasing trend for managing dorsally angulated distal radial fractures with locked volar plate fixation in fractures that may have previously been managed with percutaneous Kirschner wire (K-wire) fixation. There has been no prospective randomised trial comparing locked volar plate fixation with percutaneous K-wire fixation. in the absence of data guiding management with regard to clinical effectiveness, we have examined the cost of each technique. Methods: Patients' details were collected retrospectively between June 2007 and June 2008. Ten consecutive patients who underwent percutaneous K-wire fixation fora distal radius fracture and the 10 who were treated by locked volar plate fixation were identified and their hospital notes retrieved. All patients had a closed extra-articular distal radial fracture with dorsal angulation. The duration and type of operation, including number of wires or screws used, were recorded. Results: The mean age of the patients was 54 years for the locking plate group and 34 years for the percutaneous K-wire group. The mean time taken to perform percutaneous K-wire fixation with an average of two K-wires was 56 min. The mean time for applying a volar locked plate was 121 min. The cost of a pack of 10 K-wires was 3 pound. The total cost of a standard volar locking plate and screws used was 787 pound. Discussion: In the absence of research comparing clinical end points, cost must play a major factor in determining the type of operation offered. A 56-min operation to percutaneously fix a distal radial fracture with K-wires costs 662 pound. This compares to a cost of 2212 pound for a 121-min locked volar plate fixation. There is a calculated difference of 1549 pound and 65 min. Conclusion: With use of a locked volar plate for patients under the age of 70 years there is a loss of 652 pound for the Trust with the present NHS tariffs. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1279 / 1281
页数:3
相关论文
共 50 条
  • [31] Volar locking plates versus K-wire/pin fixation for the treatment of distal radial fractures: a systematic review and quantitative synthesis
    Franceschi, Francesco
    Franceschetti, Edoardo
    Paciotti, Michele
    Cancilleri, Francesco
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2015, 115 (01) : 91 - 110
  • [32] Treatment of distal radial fractures with antegrade intra-medullary Kirschner wires
    Mostafa, Mohamed F.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2013, 8 (02): : 89 - 95
  • [33] Fragment-specific fixation of complex distal radial fractures with small intraarticular fragments; volar locked plate augmented with Kirschner wires
    Abdelgaid, Sherif Mohamed
    Abdelazeem, Mokhtar Elsayed
    Alsharkawy, Walid
    CURRENT ORTHOPAEDIC PRACTICE, 2015, 26 (03): : 306 - 313
  • [34] VOLAR LOCKING PLATE FIXATION VERSUS CLOSED REDUCTION FOR DISTAL RADIAL FRACTURES IN ADULTS A Systematic Review and Meta-Analysis
    Lawson, Andrew
    Na, Michael
    Naylor, Justine M.
    Lewin, Adriane M.
    Harris, Ian A.
    JBJS REVIEWS, 2021, 9 (01)
  • [35] Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: A biomechanical study
    Trease, C
    McIff, T
    Toby, EB
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 756 - 763
  • [36] Volar locking plate versus percutaneous fixation for the treatment of distal radial fractures: a meta-analysis of randomized controlled trials
    Shen, Longxiang
    Wen, Mengni
    Wang, Feiyan
    Ding, Jian
    Luo, Congfeng
    Zhao, Gang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 7780 - 7793
  • [37] Volar Locking Plates Versus External Fixation and Adjuvant Pin Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study
    Williksen, John H.
    Frihagen, Frede
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Husby, Torstein
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (08): : 1469 - 1476
  • [38] Should unstable extra-articular distal radial fractures be treated with fixed angle volar locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial reply
    McCann, P. A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 1222 - 1222
  • [39] Comparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures
    Boretto, J. G.
    Pacher, N.
    Giunta, D.
    Gallucci, G. L.
    Alfie, V.
    De Carli, P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (07) : 755 - 760
  • [40] Volar Locking Plates Versus Augmented External Fixation of Intra-Articular Distal Radial Fractures Functional Results from a Randomized Controlled Trial
    Hammer, Ola-Lars
    Clementsen, Stale
    Hast, Joakim
    Benth, Jurate Saltyte
    Madsen, Jan Erik
    Randsborg, Per-Henrik
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (04): : 311 - 321