Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgery

被引:63
|
作者
Costa, P. [1 ]
Bruno, A.
Bonzanino, M.
Massaro, F.
Caruso, L.
Vincenzo, I.
Ciaramitaro, P.
Montalenti, E.
机构
[1] CTO Hosp, Clin Neurophysiol Sect, I-10126 Turin, Italy
[2] CTO Hosp, Sect Spine Surg, Turin, Italy
[3] CTO Hosp, Neurosurg Sect, Turin, Italy
[4] CTO Hosp, Sect Anesthesiol, Turin, Italy
[5] Univ Turin, Dept Neurosci, I-10124 Turin, Italy
关键词
spine surgery; spinal cord surgery; intraoperative neurophysiologic monitoring; transcranial; electrically elicited motor-evoked potentials; somatosensory-evoked potentials;
D O I
10.1038/sj.sc.3101934
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design: Prospective, observational study. Setting: Regional Trauma Center, Torino, Italy. Objectives: Complex spinal surgery carries a significant risk of neurological damage. The aim of this study is to determine the reliability and applicability of multimodality motor-evoked potentials (MEPs) and somatosensory-evoked potentials (SEPs) monitoring during spine and spinal cord surgery in our institute. Methods: Recordings of MEPs to multipulse transcranial electrical stimulation (TES) and cortical SEPs were made on 52 patients during spine and spinal cord surgery under propofol/fentanyl anaesthesia, without neuromuscular blockade. Results: Combined MEPs and SEPs monitoring was successful in 38/52 patients (73.1%), whereas only MEPs from at least one of the target muscles were obtained in 12 patients (23.1%); both MEPs and SEPs were absent in two (3.8%). Significant intraoperative-evoked potential changes occurred in one or both modalities in five (10%) patients. Transitory changes were noted in two patients, whereas three had persistent changes, associated with new defecits or a worsening of the pre-existing neurological disabilities. When no postoperative changes in MEP or MEP/SEP modalities occurred, it was predictive of the absence of new motor deficits in all cases. Conclusion: Intraoperative combined SEP and MEP monitoring is a safe, reliable and sensitive method to detect and reduce intraoperative injury to the spinal cord. Therefore, the authors suggest that a combination of SEP/MEP techniques could be used routinely during complex spine and/or spinal cord surgery.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [21] BENEFIT OF COMBINED MOTOR AND SOMATOSENSORY EVOKED POTENTIALS AND ELECTROMYOGRAPHY MONITORING DURING SURGERY OF INTRAMEDULLARY SPINAL CORD TUMOR
    Kim, Dong-Gun
    Son, Yoo Ri
    Lee, Kwang-Woo
    Park, Kyung Seok
    MUSCLE & NERVE, 2014, 50 (04) : 640 - 640
  • [22] The usefulness of motor evoked potential monitoring during spinal surgery
    Yon, J.
    Lee, S.
    Cho, J. K.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 58 - 58
  • [23] Combined motor- and somatosensory-evoked potential monitoring for spine and spinal cord surgery: correlation of clinical and neurophysiological data in 85 consecutive procedures
    Hyun, S. J.
    Rhim, S. C.
    Kang, J. K.
    Hong, S. H.
    Park, B. R. G.
    SPINAL CORD, 2009, 47 (08) : 616 - 622
  • [24] Combined motor- and somatosensory-evoked potential monitoring for spine and spinal cord surgery: correlation of clinical and neurophysiological data in 85 consecutive procedures
    S J Hyun
    S C Rhim
    J K Kang
    S H Hong
    B R G Park
    Spinal Cord, 2009, 47 : 616 - 622
  • [25] Role of motor-evoked potential monitoring in conjunction with temporary clipping of spinal nerve roots in posterior thoracic spine tumor surgery
    Eleraky, Mohammed A.
    Setzer, Matthias
    Papanastassiou, Ioannis D.
    Baaj, Ali A.
    Tran, Nam D.
    Katsares, Kiesha M.
    Vrionis, Frank D.
    SPINE JOURNAL, 2010, 10 (05): : 396 - 403
  • [26] Delayed response of transcranial myogenic motor-evoked potential monitoring to spinal cord ischemia during repair surgery for descending thoracic aortic aneurysm
    Kakinohana, Manabu
    Abe, Masanori
    Miyata, Yuji
    Oshiro, Masakatsu
    Saikawa, Satoko
    Arakaki, Katsuya
    Kuniyoshi, Yukio
    Sugahara, Kazuhiro
    JOURNAL OF ANESTHESIA, 2008, 22 (03) : 304 - 307
  • [27] Delayed response of transcranial myogenic motor-evoked potential monitoring to spinal cord ischemia during repair surgery for descending thoracic aortic aneurysm
    Manabu Kakinohana
    Masanori Abe
    Yuji Miyata
    Masakatsu Oshiro
    Satoko Saikawa
    Katsuya Arakaki
    Yukio Kuniyoshi
    Kazuhiro Sugahara
    Journal of Anesthesia, 2008, 22 : 304 - 307
  • [28] SPINAL-CORD MONITORING DURING SPINAL SURGERY USING SOMATOSENSORY SPINAL EVOKED-POTENTIALS
    LAMONT, RL
    WASSON, SL
    GREEN, MA
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1983, 3 (01) : 31 - 36
  • [29] The influence of regional spinal cord hypothermia on transcranial myogenic motor-evoked potential monitoring and the efficacy of spinal cord ischemia detection
    Meylaerts, SA
    De Haan, P
    Kalkman, CJ
    Lips, J
    De Mol, BA
    Jacobs, MJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (06): : 1038 - 1045
  • [30] Comparison of the Effects of Propofol and Sevoflurane Combined With Remifentanil on Transcranial Electric Motor-evoked and Somatosensory-evoked Potential Monitoring During Brainstem Surgery
    Hernandez-Palazon, Joaquin
    Izura, Virginia
    Fuentes-Garcia, Diego
    Piqueras-Perez, Claudio
    Domenech-Asensi, Paloma
    Falcon-Arana, Luis
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2015, 27 (04) : 282 - 288