Modelling of the impedance frequency response of transformers at no load and under nominal conditions

被引:4
|
作者
Januario, Marconi [1 ]
Kuo-Peng, Patrick [2 ]
Batistela, Nelson Jhoe [2 ]
机构
[1] Univ Oeste Santa Catarina, Elect Engn Course, Joacaba, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Elect Engn, Florianopolis, SC, Brazil
关键词
D O I
10.1049/iet-epa.2014.0307
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The need for models that represent the behaviour of transformers operating in steady state or submitted to transient events is of great importance in studies involving power systems. In this context, this study presents a model used to represent the impedance frequency response of transformers at no load and under nominal conditions. In the model, networks of parameters with RLC cells are employed to reproduce the resonances present in the frequency responses and also RL network sections are used to represent the frequency-dependent effects in the core, which aid in the current damping during transient events. The parameter values of these networks are determined with the least-squares numerical method. To evaluate the model as well as the methodology to determine the parameter values, data originating from measurements of the frequency responses with frequency range from 10 Hz to 2 MHz of two single-phase transformers (16 kVA and 55 MVA) are used. Validations of the model are carried out in the frequency and time domains. The model can be used to simulate transformer operation under nominal conditions of voltage and frequency and also for a broad frequency spectrum.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 50 条
  • [41] Leakage impedance design as function of frequency scaling in power transformers
    Odendaal, WG
    Ferreira, JA
    Roos, SD
    IAS '96 - CONFERENCE RECORD OF THE 1996 IEEE INDUSTRY APPLICATIONS CONFERENCE, THIRTY-FIRST IAS ANNUAL MEETING, VOLS 1-4, 1996, : 1389 - 1396
  • [43] Impedance Measurement of Batteries under load
    Hasan, Rahat
    Scott, Jonathan
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 349 - 352
  • [44] Modelling the response of tomato on deficit irrigation under greenhouse conditions
    Locatelli, Silvia
    Barrera Jr, Wilfredo
    Verdi, Leonardo
    Nicoletto, Carlo
    Marta, Anna Dalla
    Maucieri, Carmelo
    SCIENTIA HORTICULTURAE, 2024, 326
  • [45] Load modelling for analysis of power-system harmonics under unbalanced conditions
    Sainz, L
    Clua, J
    Jordi, O
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2001, 11 (01): : 49 - 56
  • [46] Modelling and analysis of operation PMSG based WECS under different load conditions
    Gencer, Altan
    2016 8TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI), 2016,
  • [47] Numerical modelling of load bearing steel stud walls under fire conditions
    Gunalan, S.
    Mahendran, M.
    INCORPORATING SUSTAINABLE PRACTICE IN MECHANICS OF STRUCTURES AND MATERIALS, 2011, : 501 - 506
  • [48] Mixed Derating of Distribution Transformers Under Unbalanced Supply Voltage and Nonlinear Load Conditions Using TSFEM
    Faiz, Jawad
    Ebrahimi, Bashir Mahdi
    Ghofrani, Mahmoud
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 780 - 789
  • [49] Load Transfer Among Spur Gear Teeth with Tip Relief Under Non-nominal Loading Conditions
    Pleguezuelos, Miguel
    Sanchez, Miryam B.
    Pedrero, Jose, I
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON MECHANISM SCIENCE, EUCOMES 2018, 2019, 59 : 299 - 306
  • [50] Frequency response function expansion for unmeasured translation and rotation dofs for impedance modelling applications
    Avitabile, P
    O'Callahan, J
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2003, 17 (04) : 723 - 745