Terbium(III) Ion-Selective Electrochemical Sensor Based on Hematoporphyrin

被引:51
|
作者
Mohammadhossieni, Majed [2 ]
Zamani, Hassan Ali [1 ]
Nekoei, Mehdi [2 ]
机构
[1] Islamic Azad Univ, Quchan Branch, Dept Appl Chem, Quchan, Iran
[2] Islamic Azad Univ, Shahroud Branch, Dept Chem, Shahroud, Iran
关键词
Ion-selective electrode; Potentiometry; PVC membrane; Sensor; Terbium (III); PVC-MEMBRANE-ELECTRODE; SEDIMENT SAMPLES; NEUTRAL IONOPHORE; SCHIFFS BASE; COPPER(II)-SELECTIVE ELECTRODE; DYSPROSIUM(III) ION; CONSTRUCTION; CARRIER; SOIL; FABRICATION;
D O I
10.1080/00032710802585675
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyvinyl chloride (PVC) based membrane sensor for terbium ions was prepared by employing Hematoporphyrin (HP) as an ionophore. The sensor revealed a very good selectivity (expect for the Fe3+ion) with respect to common alkali, alkaline earth and heavy metal ions. The plasticized membrane electrode exhibits a Nernstian response for Tb3+ ions over a wide concentration range (1.010-6-1.010-2M) with a slope of 19.80.3mV per decade and low detection limit of 7.410-7M. The developed sensor was used in determination of F- in mouth wash preparation sample.
引用
收藏
页码:298 / 311
页数:14
相关论文
共 50 条
  • [41] Ion-Selective Adsorption of Lead by a Two-Dimensional Terbium Oxalate Framework
    Nankawa, Takuya
    Sekine, Yurina
    Yamada, Teppei
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2022, 95 (05) : 825 - 829
  • [42] Fabrication of an Electrochemical Sensor Based on Electropolymerized ion Imprinted Polymer for Selective Determination of Iron(III) Ions
    Veysi, Alireza
    Roushani, Mahmoud
    Rajabi, Hamid Reza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2025, 12 (01): : 47 - 56
  • [43] ELECTROCHEMICAL TREATMENT OF MATERIALS WITH AID OF ION-SELECTIVE ELECTRODES
    KROKHV, VV
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1976, 49 (06): : 1343 - 1347
  • [44] ELECTROCHEMICAL STUDIES ON ION-SELECTIVE POLYMER MEMBRANE ELECTRODES
    CRAWLEY, CD
    RECHNITZ, GA
    JOURNAL OF MEMBRANE SCIENCE, 1985, 24 (02) : 201 - 219
  • [45] COMPUTER DATABASE ON ION-SELECTIVE ELECTRODES AND ELECTROCHEMICAL SENSORS
    OKAZAKI, S
    FUJINAGA, T
    DENKI KAGAKU, 1982, 50 (01): : 115 - 116
  • [46] INVESTIGATION OF ION-SELECTIVE MEMBRANES WITH SCANNING ELECTROCHEMICAL MICROSCOPY
    TOTH, K
    NAGY, G
    HORROCKS, BR
    BARD, AJ
    MAGYAR KEMIAI FOLYOIRAT, 1993, 99 (09): : 339 - 348
  • [47] Ion imprinted polymer based ion-selective electrode for the trace determination of dysprosium(III) ions
    Prasad, K
    Kala, R
    Rao, TP
    Naidu, GRK
    ANALYTICA CHIMICA ACTA, 2006, 566 (01) : 69 - 74
  • [48] THE EFFECT OF IRON(III) ON THE CADMIUM ION-SELECTIVE ELECTRODE
    SAKURA, S
    VIRTANEN, R
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1981, 54 (05) : 1360 - 1363
  • [49] Fabrication of butyrylcholinesterase sensor using polyurethane-based ion-selective membranes
    Cho, YA
    Lee, HS
    Cha, GS
    Lee, YT
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (04): : 435 - 438
  • [50] Nitrate ion-selective sensor based on electrochemically prepared conducting polypyrrole films
    Sun, BT
    Fitch, PG
    ELECTROANALYSIS, 1997, 9 (06) : 494 - 497