Improved quantification in pinhole gated myocardial perfusion SPECT using micro-CT and ultrasound information

被引:5
|
作者
Goethals, Lode R. [1 ,2 ]
De Geeter, Frank [2 ]
Vanhove, Chris [5 ]
Roosens, Bram [2 ,4 ]
Devos, Hannes [2 ]
Lahoutte, Tony [2 ,3 ]
机构
[1] Univ Hosp Brussels, Dept Radiol, Brussels, Belgium
[2] Vrije Univ Brussel, Vivo Cellular & Mol Imaging Lab, Brussels, Belgium
[3] Univ Hosp Brussels, Dept Nucl Med, Brussels, Belgium
[4] Univ Hosp Brussels, Dept Cardiol, Brussels, Belgium
[5] UGENT, INFINITY, MEDISIP, Ghent, Belgium
关键词
pinhole SPECT; myocardial perfusion imaging; quantification; partial volume effect; SMALL-ANIMAL SPECT; SCATTER COMPENSATION; LINE SOURCE; ATTENUATION; EMISSION; RATS; CALIBRATION; RESOLUTION;
D O I
10.1002/cmmi.477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Absolute quantification using single photon emission computed tomography (SPECT) was demonstrated in vitro and in large immobile organs in vivo. To determine the feasibility of in vivo quantification of myocardial perfusion in pinhole gated SPECT, we added an ultrasound derived partial volume correction factor to attenuation and scatter corrections, in combination with gated acquisitions. In nine male Wistar rats, cardiac ultrasound was performed prior to SPECT/CT scans to determine the myocardial wall thickness. SPECT/CT scans were then performed 30?min after injection of 99mTc Tetrofosmin. Animals were killed and six midventricular segments of the left ventricle were excised and counted in a ?-well counter. Using AMIDE, regional myocardial activity was measured after combined scatter correction (SC) and attenuation correction (AC). These image derived activities were compared with the ex vivo counted activity. To correct for the partial volume effect, a recovery coefficient was determined from a phantom study, to determine the thickness specific partial volume effect. Combined AC and SC led to a significant underestimation of activity compared with ex vivo data (root mean squared error?=?0.145?mCi?g-1). The recovery coefficient calculated from the phantom study showed a linear relationship with object size from 1 to 6?mm, positioned in the vicinity of the center of the field of view (R2?=?0.98). Correction of nongated SPECT images with a recovery coefficient derived from the diastolic phase results in a global overestimation with root mean squared error?=?0.04?mCi?g-1. Nongated SPECT images corrected with a recovery coefficient with a weighted average ratio diastolic and systolic phase led to an improved root mean squared error of 0.03?mCi?g-1. Combining attenuation correction with scatter correction and a gated partial volume correction yields the best correlation with ex vivo counting (root mean squared error?=?0.021?mCi?g-1 (systolic) and 0.025?mCi?g-1 (diastolic). This study demonstrates a method for improved segmental myocardial perfusion quantification in pinhole gated SPECT, using combined attenuation-, scatter- and ultrasound-derived partial volume effect corrections. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [41] Ischemia Detection Can Be Improved with the Use of the Phase Analysis on Gated SPECT Myocardial Perfusion Studies
    Ruano Perez, R.
    Diego Dominguez, M.
    Diaz Gonzalez, L.
    Diego Nieto, A.
    Garcia Piney, E.
    Garcia-Talavera, J. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S605 - S605
  • [42] Comparison of TI-201 myocardial perfusion gated SPECT versus gated blood pool SPECT for the quantification of global and regional left ventricular function
    Daou, D.
    Coaguila, C.
    Benada, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S198 - S198
  • [43] Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT
    Lum, DP
    Coel, MN
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (03) : 259 - 266
  • [44] Quantification of saved myocardium after primary angioplasty with myocardial perfusion gated-SPECT.: Preliminary results
    Pujol, P.
    De Leon, G.
    Aguade-Bruix, S.
    Del Blanco, B. Garcia
    Rossi, S.
    Falu, R.
    Figueras, J.
    Castell-Conesa, J.
    Candell-Riera, J.
    CIRCULATION, 2008, 118 (12) : E320 - E320
  • [45] Methodology for micro-CT data inflation using Intravascular Ultrasound images
    Rigas, George A.
    Athanasiou, Lambros S.
    Sakellarios, Antonios I.
    Exarchos, Themis P.
    Siogkas, Panagiotis K.
    Naka, Katerina K.
    Panetta, Daniele
    Pelosi, Gualtiero
    Michalis, Lampros K.
    Parodi, Oberdan
    Fotiadis, Dimitrios I.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1099 - 1102
  • [46] Potential to normalise myocardial perfusion SPECT using CT: Technical considerations
    Rajasekharan, S.
    Hutton, B.
    Groves, A.
    Goh, V.
    Dickson, J.
    Shastry, M.
    Menezes, L.
    Endozo, R.
    Ell, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S262 - S262
  • [47] Erratum: Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering
    Philipp S. Lienemann
    Stéphanie Metzger
    Anna-Sofia Kiveliö
    Alain Blanc
    Panagiota Papageorgiou
    Alberto Astolfo
    Bernd R. Pinzer
    Paolo Cinelli
    Franz E. Weber
    Roger Schibli
    Martin Béhé
    Martin Ehrbar
    Scientific Reports, 5
  • [48] Comparison of the biodistribution and tumor targeting of two 99mTc-labeled anti-EGFR nanobodies in mice, using pinhole SPECT/micro-CT
    Gainkam, Lea Olive Tchouate
    Huang, Lieven
    Caveliers, Vicky
    Keyaerts, Marleen
    Hernot, Sophie
    Vaneycken, Ilse
    Vanhove, Christian
    Revets, Hilde
    De Baetselier, Patrick
    Lahoutte, Tony
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (05) : 788 - 795
  • [49] Mathematical Data Processing of Gated Spect Myocardial Perfusion Imaging with Using Wavelet Analysis
    Babin, Andrey V.
    Kotina, Elena D.
    2014 INTERNATIONAL CONFERENCE ON COMPUTER TECHNOLOGIES IN PHYSICAL AND ENGINEERING APPLICATIONS (ICCTPEA), 2014, : 19 - 20
  • [50] Assessment of Myocardial Perfusion and Function in Victims of Scorpion Envenomation Using Gated-SPECT
    de Figueiredo, Alexandre Baldini
    Cupo, Palmira
    Pintya, Antonio O.
    Caligaris, Fabio
    Marin-Neto, Jose A.
    Hering, Sylvia E.
    Simoes, Marcus Vinicius
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 94 (04) : 444 - 451