Development of patch-type sensor module for wireless monitoring of heart rate and movement index

被引:16
|
作者
Li, Meina [1 ]
Kim, Youn Tae [1 ]
机构
[1] Chosun Univ, Grad Sch, Dept IT Fusion Technol, Kwangju, South Korea
基金
新加坡国家研究基金会;
关键词
Heart rate; Movement sensors; Athletics training; HEALTH; INJURY;
D O I
10.1016/j.sna.2011.10.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A patch-type sensor module (AIRBEAT System) for wireless monitoring of heart rate and movement index has been developed and evaluated. The major components of the system are the sensor board, the rubber case, and the communication module. The small sensor is patched onto the subject's chest to obtain physiological data, including heart rate and movement index. The relation test for heart rate yields an error rate within 2% compared with the CASE system (GE, USA). A three-axis accelerometer was chosen because of its low power consumption and very small size. The correlation coefficient between the average movement index and the conventionally used agility point score was found to be in the range of 0.8-0.9.A commercially available Zigbee telecommunication system was used for communication over distances of more than 400 m in an open space. According to the Bruce test protocol, changes in heart rate and movement index can be efficiently monitored and measured using the device. It has also been confirmed that the patch-type sensor module with built-in analysis algorithm can be used as an efficient tool for athletic training. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [21] Feasibility of patch-type wireless 12-lead electrocardiogram in laypersons
    Yoon, Sunyoung
    Kim, Taerim
    Kang, Eunjin
    Heo, Sejin
    Chang, Hansol
    Seo, Yeoni
    Cha, Won Chul
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [22] Wireless sensor module for habitat monitoring
    Pendock, Graeme J.
    Evans, Lisa
    Coulson, Graeme
    PROCEEDINGS OF THE 2007 INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS AND INFORMATION PROCESSING, 2007, : 699 - +
  • [23] Development of a Disposable Wireless Sensor for Monitoring Patient Movement and Activity
    Larson, Barrett
    Shen, Daniel
    ANESTHESIA AND ANALGESIA, 2014, 119
  • [24] Utility of duranta®, a wireless patch-type electrocardiographic monitoring system, for detecting atrial fibrillation in patients with cryptogenic stroke
    Akiyama, H.
    Araga, T.
    Hasegawa, Y.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 391 - 392
  • [25] Development of a portable integrated wireless sensor module for structural damage monitoring
    Pidaparti, Ramana M.
    Belle, Ashwin
    Wang, Ju
    SDHM Structural Durability and Health Monitoring, 2009, 5 (04): : 295 - 310
  • [26] Flexible patch-type hydrochromic polydiacetylene sensor for human sweat pore mapping
    Seo, Minjeong
    Park, Dong-Hoon
    Park, Bum Jun
    Kim, Jong-Man
    JOURNAL OF APPLIED POLYMER SCIENCE, 2017, 134 (06)
  • [27] Development and Analysis of Wireless Heart Rate Monitoring Device
    Daud, H.
    Gulcharan, N. F. I.
    Azhar, M. A. M.
    Nor, N. M.
    Ibrahim, T.
    2014 INTERNATIONAL CONFERENCE ON INDUSTRIAL AUTOMATION, INFORMATION AND COMMUNICATIONS TECHNOLOGY (IAICT), 2014, : 57 - 63
  • [28] A Combined Heart Rate and Movement Index Sensor for Estimating the Energy Expenditure
    Meina, Li
    Kim, Jang Myoung
    Kim, Youn Tae
    2010 IEEE SENSORS, 2010, : 809 - 812
  • [29] A Patch-Type Wireless Forehead Pulse Oximeter for SpO2 Measurement
    Azhari, A.
    Yoshimoto, S.
    Nezu, T.
    Iida, H.
    Ota, H.
    Noda, Y.
    Araki, T.
    Uemura, T.
    Sekitani, T.
    Morii, K.
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [30] Patch-Type Vibration Visualization (PVV) Sensor System Based on Triboelectric Effect
    Kim, Sun-Jin
    Seol, Myeong-Lok
    Chung, Byun-Young
    Jang, Dae-Sic
    Kim, Jong-Hwan
    Choi, Young-Chul
    SENSORS, 2021, 21 (12)