Development of patch-type sensor module for wireless monitoring of heart rate and movement index

被引:16
|
作者
Li, Meina [1 ]
Kim, Youn Tae [1 ]
机构
[1] Chosun Univ, Grad Sch, Dept IT Fusion Technol, Kwangju, South Korea
基金
新加坡国家研究基金会;
关键词
Heart rate; Movement sensors; Athletics training; HEALTH; INJURY;
D O I
10.1016/j.sna.2011.10.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A patch-type sensor module (AIRBEAT System) for wireless monitoring of heart rate and movement index has been developed and evaluated. The major components of the system are the sensor board, the rubber case, and the communication module. The small sensor is patched onto the subject's chest to obtain physiological data, including heart rate and movement index. The relation test for heart rate yields an error rate within 2% compared with the CASE system (GE, USA). A three-axis accelerometer was chosen because of its low power consumption and very small size. The correlation coefficient between the average movement index and the conventionally used agility point score was found to be in the range of 0.8-0.9.A commercially available Zigbee telecommunication system was used for communication over distances of more than 400 m in an open space. According to the Bruce test protocol, changes in heart rate and movement index can be efficiently monitored and measured using the device. It has also been confirmed that the patch-type sensor module with built-in analysis algorithm can be used as an efficient tool for athletic training. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [1] A wireless patch-type physiological monitoring microsystem
    Ke, Ting-Chen
    Yang, Kuo-Yu
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1159 - +
  • [2] A patch-type wireless physiological monitoring microsystems
    Ke, T. C.
    Lin, W. S.
    Chang, W. Y.
    HEALTHCOM 2007: UBIQUITOUS HEALTHCARE IN AGING SOCIETIES, 2007, : 208 - +
  • [3] Development of Patch-Type Sensor Module for Battery-Free Power Transfer and Data Transmission
    Lee, Janghyun
    Kim, Young Su
    Kim, Woo Young
    Kim, Youn Tae
    2015 IEEE SENSORS, 2015, : 343 - 346
  • [4] Intelligent Predictor of Energy Expenditure with the Use of Patch-Type Sensor Module
    Li, Meina
    Kwak, Keun-Chang
    Kim, Youn-Tae
    SENSORS, 2012, 12 (11) : 14382 - 14396
  • [5] Development of a Patch-Type Flexible Oxygen Partial Pressure Sensor
    Katayama, Yuta
    Fujioka, Yuta
    Tsukada, Kosuke
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2020, 8 (08):
  • [6] Wireless Patch Sensor for Remote Monitoring of Heart Rate, Respiration, Activity, and Falls
    Chan, Alexander M.
    Selvaraj, Nandakumar
    Ferdosi, Nima
    Narasimhan, Ravi
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 6115 - 6118
  • [7] Monitoring Energy Cost Using a Wireless Patch Type Sensor Module with Embedded Algorithm
    Meina, Li
    Kang, Kyeung Ho
    Oh, Wang Keun
    Kim, Youn Tae
    2012 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2012), 2012, : 204 - 207
  • [8] Development of circular patch-type electric field sensor for printed circuits
    Kurokawa, S
    Sato, T
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 2004, 87 (11): : 57 - 67
  • [9] Development of a Patch-Type Electrocardiographic Monitor for Real Time Heartbeat Detection and Heart Rate Variability Analysis
    Liu, Shing-Hong
    Wang, Jia-Jung
    Su, Chun-Hung
    Tan, Tan-Hsu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (03) : 411 - 423
  • [10] Development of a Patch-Type Electrocardiographic Monitor for Real Time Heartbeat Detection and Heart Rate Variability Analysis
    Shing-Hong Liu
    Jia-Jung Wang
    Chun-Hung Su
    Tan-Hsu Tan
    Journal of Medical and Biological Engineering, 2018, 38 : 411 - 423