The Gastro-Laryngeal Tube for interventional endoscopic biliopancreatic procedures in anesthetized patients

被引:18
|
作者
Fabbri, C. [1 ]
Luigiano, C. [2 ]
Cennamo, V. [3 ]
Polifemo, A. M. [1 ]
Maimone, A. [1 ]
Jovine, E. [4 ]
D'Imperio, N. [1 ]
Zanello, M. [5 ]
机构
[1] AUSL Bologna Bellaria Maggiore Hosp, Unit Gastroenterol & Digest Endoscopy, Bologna, Italy
[2] ARNAS Garibaldi, Unit Gastroenterol & Digest Endoscopy, Catania, Italy
[3] AUSL Bologna Bellaria Hosp, Unit Metropolitan Digest Endoscopy, Dept Surg, I-40139 Bologna, Italy
[4] AUSL Bologna Maggiore Hosp, Unit Gen Surg, Bologna, Italy
[5] IRCCS Ist Sci Neurol Bellaria Hosp, Bologna, Italy
关键词
RETROGRADE CHOLANGIOPANCREATOGRAPHY; GENERAL-ANESTHESIA; MASK AIRWAY; INTUBATION;
D O I
10.1055/s-0032-1310159
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The Gastro-Laryngeal Tube (G-LT) is a modification of the laryngeal tube which provides a dedicated channel for the insertion of an endoscope while acting as a supraglottic airway for ventilation. The aim of this study was to assess the safety and effectiveness of this device in patients undergoing anesthesia for interventional endoscopic biliopancreatic procedures (IEBPPs). A total of 22 patients were included in the study. The G-LT was inserted successfully in all patients. Arterial oxygen saturation was stable; the mean value was 97.9%. The IEBPPs were performed successfully in all patients through the endoscopic channel, with a mean duration of 99 minutes. The maneuverability of the endoscope was considered good in all patients. There were two cases of sore throat after the procedures, two cases of asymptomatic erosion of the upper esophageal mucosa, one case of Mallory-Weiss syndrome, and one case of pancreatitis after endoscopic retrograde cholangiopancreatography. Our results suggest that the G-LT is an effective and secure device for airway management and for use during IEBPPs.
引用
收藏
页码:1051 / 1054
页数:4
相关论文
共 50 条
  • [11] MANAGEMENT OPTIONS FOR TWISTED GASTRIC TUBE AFTER LAPAROSCOPIC WEEVEGASTRECTOMY Endoscopic and Percutaneous Interventional Procedures
    Salama, A.
    OBESITY SURGERY, 2017, 27 : 491 - 491
  • [12] LMA Gastro™ airway is feasible during upper gastrointestinal interventional endoscopic procedures in high risk patients: a single-center observational study
    Schmutz, Axel
    Loeffler, Thomas
    Schmidt, Arthur
    Goebel, Ulrich
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [13] COMPARATIVE EFFECTS OF LARYNGEAL MASK AND TRACHEAL TUBE ON TOTAL RESPIRATORY RESISTANCE IN ANESTHETIZED PATIENTS
    BOISSONBERTRAND, D
    HANNHART, B
    ROUSSELOT, JM
    DUVIVIER, C
    QUILICI, N
    PESLIN, R
    ANAESTHESIA, 1994, 49 (10) : 846 - 849
  • [14] LMA Gastro™ airway is feasible during upper gastrointestinal interventional endoscopic procedures in high risk patients: a single-center observational study
    Axel Schmutz
    Thomas Loeffler
    Arthur Schmidt
    Ulrich Goebel
    BMC Anesthesiology, 20
  • [15] Randomized prospective study comparing the laryngeal tube suction II with the ProSeal™ Laryngeal Mask Airway in anesthetized and paralyzed patients
    Kikuchi, Tatsuaki
    Kamiya, Yoshinori
    Ohtsuka, Tsuyoshi
    Miki, Tomoko
    Goto, Takahisa
    ANESTHESIOLOGY, 2008, 109 (01) : 54 - 60
  • [16] FISTULA GASTRO-GASTRIC AFTER ROUX-EN-Y GASTRIC BYPASS Endoscopic and percutaneous interventional procedures
    Lopez Corvala, J.
    Guerrero Burgueno, W.
    Melgem Lizarraga, J.
    Martinez Castro, S.
    Zepeda Gonzalez, D.
    Casillas Cardenas, J.
    OBESITY SURGERY, 2022, 32 (SUPPL 2) : 869 - 869
  • [17] Bleeding After Elective Interventional Endoscopic Procedures in a Large Cohort of Patients With Cirrhosis
    Kundumadam, Shanker
    Phatharacharukul, Parkpoom
    Reinhart, Kathryn
    Yousef, Andrew
    Shamseddeen, Hani
    Pike, Francis
    Patidar, Kavish R.
    Gromski, Mark
    Chalasani, Naga
    Orman, Eric S.
    CLINICAL AND TRANSLATIONAL GASTROENTEROLOGY, 2020, 11 (12) : e00288
  • [18] Conscious sedation for endoscopic and non-endoscopic interventional procedures: meeting patients' expectations, missing the standard
    Hancock, J
    Mawer, R
    CLINICAL RADIOLOGY, 2004, 59 (09) : 853 - 854
  • [19] Evaluating the risk of adverse events with interventional endoscopic retrograde cholangiopancreatography and endoscopic ultrasound procedures in cirrhotic patients
    Yoo, Timothy
    Epistola, Raisa
    Epistola, Jordan
    Ku, Lawrence
    Fleischman, Michael W.
    Reicher, Sofiya
    Eysselein, Viktor E.
    Hou, Linda A.
    WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2019, 11 (11):
  • [20] Pulmonary airway resistance with the endotracheal tube versus laryngeal mask airway in paralyzed anesthetized adult patients
    Berry, A
    Brimacombe, J
    Keller, C
    Verghese, C
    ANESTHESIOLOGY, 1999, 90 (02) : 395 - 397