MV Underground Cables: Effects of Soil Thermal Resistivity on Anomalous Working Temperatures

被引:0
|
作者
Calcara, L. [1 ]
Sangiovanni, S. [1 ]
Pompili, M. [1 ]
机构
[1] Sapienza Univ Roma, Astronaut Elect & Energet Engn Dept DIAEE, Rome, Italy
关键词
underground cables; cable joints; failures; thermal soil resistivity; resilience;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
One of the parameters that has to be considered in designing underground cables is the thermal resistivity of the soil along their routes. In fact, the ampacity of the MV underground cables having different types of insulation is normally evaluated through the application of the IEC Standard 60287-x "Electric cables - Calculation of the current rating". This series of IEC Standard is formed of three parts as in the following: part 1: Formulae of ratings and power losses; part 2: Formulae for thermal resistance; part 3: Sections on operating conditions. In Italy, the current capacity of the same MV cables is established by the Italian Standard CEI-UNEL 35027 (2009) "Power cables with rated voltages from 1 kV to 30 kV - Steady state current ratings: cables laid in air and in ground", which are based on the above mentioned IEC Standard. These thermal ampacities of the underground cables are function of ambient temperature and the thermal resistivity of the soil. The soil thermal resistivity is a parameter not easy to evaluate and for this reason, several times, only typical values are assumed just in function of the kind of the interested terrain (organic, loam, quartz sand, etc.). This assumption ignores the fact that the thermal resistivity varies continuously day by day especially in function of humidity soil content, being strongly dependent from this parameter. This paper describes as important differences of thermal resistivity may be present in consequence of seasonal variation in moisture content of the soil. It is also shown as such variations may cause important anomalous increases of cable maximum working temperature, which may be assumed to be at the origin of unexpected failures especially in correspondence of MV cable joints. In fact, the joints are, still today, the weakest points of the underground cables where the breakdown easily occurs due to poor workmanship, moisture ingress and thermal degradation. This thermal degradation may be also due to circulation of fault current in the metallic sheaths.
引用
收藏
页数:5
相关论文
共 41 条
  • [21] Implementation of Unbalanced Thermoelectric Equivalent Circuit for Power Flow and Thermal Rating of Underground LV and MV Cables
    Pompodakis, Evangelos E.
    Chrysochos, Andreas I.
    Ahmed, Arif
    Alexiadis, Minas C.
    Karapidakis, Emmanuel
    TechRxiv, 2021,
  • [22] Introducing Mutual Heating Effects in the Ladder-Type Soil Model for the Dynamic Thermal Rating of Underground Cables
    Diaz-Aguilo, Marc
    de Leon, Francisco
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (04) : 1958 - 1964
  • [23] Adaptive soil model for real-time thermal rating of underground power cables
    Diaz-Aguilo, Marc
    de Leon, Francisco
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (06) : 654 - 660
  • [24] Ladder-Type Soil Model for Dynamic Thermal Rating of Underground Power Cables
    Diaz-Aguiló, Marc
    De León, Francisco
    Jazebi, Saeed
    Terracciano, Matthew
    IEEE Power and Energy Technology Systems Journal, 2014, 1 : 21 - 30
  • [25] ANOMALOUS HALL RESISTIVITY IN AMORPHOUS MAGNETIC MATERIALS EFFECTS OF THERMAL ANNEALING
    MALMHALL, R
    BACKSTROM, G
    BHAGAT, SM
    RAO, KV
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (03): : 265 - 265
  • [26] PRACTICAL ASPECTS OF APPLYING SOIL THERMAL STABILITY MEASUREMENTS TO THE RATING OF UNDERGROUND POWER CABLES.
    Martin Jr., M.A.
    Bush, R
    Black, W.Z.
    Hartley, J.G.
    Engineering News-Record, 1981,
  • [27] Estimation of soil thermal parameters from surface temperature of underground cables and prediction of cable rating
    Li, HJ
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (06) : 849 - 854
  • [28] Thermal performance of underground power cables with constant and cyclic currents in presence of moisture migration in the surrounding soil
    Freitas, DS
    Prata, AT
    deLima, AJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1159 - 1170
  • [29] PRACTICAL ASPECTS OF APPLYING SOIL THERMAL-STABILITY MEASUREMENTS TO THE RATING OF UNDERGROUND POWER-CABLES
    MARTIN, MA
    BUSH, RA
    BLACK, WZ
    HARTLEY, JG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (09): : 4236 - 4249
  • [30] Influence of soil humidity on the thermal impedance, time constant and structure function of underground cables: A laboratory experiment
    Chatzipanagiotou, Panagiotis
    Chatziathanasiou, Vasilis
    De Mey, Gilbert
    Wiecek, Boguslaw
    APPLIED THERMAL ENGINEERING, 2017, 113 : 1444 - 1451