Ankle Kinematics Describing Gait Agility: Considerations in the Design of an Agile Ankle-Foot Prosthesis

被引:0
|
作者
Ficanha, Evandro M. [1 ]
Kang, Ruiyu [1 ]
Rastgaar, Mohammad [1 ]
机构
[1] Michigan Technol Univ, Dept Mech Engn Engn Mech, Houghton, MI 49931 USA
基金
美国国家科学基金会;
关键词
WALKING;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The designs of available lower extremity powered prostheses are focused on a single degree of freedom (DOF) in sagittal plane, allowing the control of their ankle joints in dorsiflexion and plantarflexion. The human gait however, shows that the ankle movements in both sagittal and frontal planes are significant even during walking on a straight path. Additionally, there is a significant change in the ankle movements during straight walking compared to turning and cutting, especially in frontal plane. A better understanding of the ankle characteristics in both sagittal and frontal planes may result in the design of significantly more effective lower extremity prostheses that mimic the ankle function and improve the agility of gait. In this paper, the ankle rotations are estimated during step turn and cutting to provide evidence for necessity of a multi-axis design while providing the preliminary design parameters for a prototype multi-axis powered ankle-foot prosthesis. It is shown that the proposed cable-driven prototype is capable of closely mimicking the ankle movements in both sagittal and frontal planes during turning and walking on a straight path.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [31] Design of Powered Ankle-Foot Prosthesis Driven by Parallel Elastic Actuator
    Gao, Fei
    Liao, Wei-Hsin
    Ma, Hao
    Qin, Lai-Yin
    Chen, Bing
    PROCEEDINGS OF THE IEEE/RAS-EMBS INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR 2015), 2015, : 374 - 379
  • [32] Ankle-foot simulator development for testing ankle-foot orthoses
    Lai, Hung-Jen
    Yu, Chung-Huang
    Kao, Hung-Chan
    Chen, Wen-Chuan
    Chou, Chi-Wei
    Cheng, Cheng-Kung
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (06) : 623 - 629
  • [33] A PASSIVE ANKLE-FOOT PROSTHESIS WITH ENERGY RETURN TO MIMIC ABLE-BODIED GAIT
    Holgate, Robert
    Sugar, Thomas
    Nash, Audrey
    Kianpour, Jasper
    Johnson, Craig Trevor
    Santos, Edwin
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2017, VOL 5A, 2017,
  • [34] Design and Evaluation of an Active/Semiactive Ankle-Foot Orthosis for Gait Training
    Zhang, Yufeng
    Kleinmann, Roger J.
    Nolan, Karen J.
    Zanotto, Damiano
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 544 - 549
  • [35] Design of a Hydraulic Ankle-Foot Orthosis
    Gmerek, Artur
    Meskin, Nader
    Tehrani, Ehsan Sobhani
    Kearney, Robert
    2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2016, : 1041 - 1048
  • [36] Bimodal ankle-foot prosthesis for enhanced standing stability
    Koehler-McNicholas, Sara R.
    Slater, Billie C. Savvas
    Koester, Karl
    Nickel, Eric A.
    Ferguson, John E.
    Hansen, Andrew H.
    PLOS ONE, 2018, 13 (09):
  • [37] Powered Ankle-Foot Prosthesis for the improvement of amputee ambulation
    Au, Samuel K.
    Herr, Hugh
    Weber, Jeff
    Martinez-Villalpando, Ernesto C.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3020 - 3026
  • [38] GAIT ABNORMALITIES IN HEMIPLEGIA - THEIR CORRECTION BY ANKLE-FOOT ORTHOSES
    LEHMANN, JF
    CONDON, SM
    PRICE, R
    DELATEUR, BJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1987, 68 (11): : 763 - 771
  • [39] Design of an Active Ankle-Foot Prosthesis Utilizing a Four-Bar Mechanism
    Bergelin, Bryan J.
    Voglewede, Philip A.
    JOURNAL OF MECHANICAL DESIGN, 2012, 134 (06)
  • [40] HEMIPARETIC GAIT ABNORMALITIES - THEIR CORRECTION BY ANKLE-FOOT ORTHOSES
    LEHMANN, JF
    CONDON, S
    PRICE, R
    DELATEUR, BJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1987, 68 (09): : 591 - 591