Immunoassay of interferon gamma by quartz crystal microbalance biosensor

被引:13
|
作者
Pohanka, Miroslav [1 ]
机构
[1] Univ Def, Fac Mil Hlth Sci, Trebesska 1575, CZ-50001 Hradec Kralove, Czech Republic
关键词
Bioassay; Biosensor; Cytokine; Diagnosis; ELISA; Immunoassay; Immunosensor; Infection; Lymphocyte; Macrophage; Virus; IFN-GAMMA; IMMOBILIZATION; ALPHA; ASSAY;
D O I
10.1016/j.talanta.2020.121167
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interferon gamma (IFN gamma) is a cytokine and an immunochemical marker that can be used for revealing of infectious diseases and especially for distinguishing of viral and some types of bacterial infections. Blood tests for IFN gamma are typically based on immunoassays like Enzyme-Linked Immunosorbent Assay (ELISA). In this paper, a biosensor working on the principle of quartz crystal microbalance (QCM) was developed as an alternative to the standard analytical methods for IFN gamma. The biosensor contained antibodies against IFN gamma immobilized on QCM and also on gold nanoparticles. A sandwich containing QCM, gold nanoparticles and IFN gamma was formed and formation of the sandwich caused decrease of oscillation frequency. The assay exerted limit of detection 5.7 pg/ml for a sample sized 50 mu l and one measuring cycle was finished within 90 min. The assay by biosensor fully correlated to standard ELISA. In a conclusion, the biosensor appears to be a fully applicable analytical tool for a simple assay of IFN gamma. Overall simplicity and no special requirement on staff and equipment are the major advantages of the here presented assay.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] QUARTZ CRYSTAL MICROBALANCE BIOSENSOR FOR SAXITOXIN BASED ON IMMOBILIZED SODIUM CHANNEL RECEPTORS
    Bergantin, Jose H.
    Sevilla, Fortunato, III
    ANALYTICAL LETTERS, 2010, 43 (03) : 476 - 486
  • [22] Construction of a bilirubin biosensor based on an albumin-immobilized quartz crystal microbalance
    Kocakulak, Mustafa
    Bayrak, Tuncay
    Saglam, Sinan
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2017, 37 (03) : 611 - 617
  • [23] The Analysis of IgG-Protein A Binding Effect by Quartz Crystal Microbalance Biosensor
    Cheng, Chi-Jung
    Feng, Chen-Tung
    Atashbar, Massood Z.
    2010 IEEE SENSORS, 2010, : 228 - 231
  • [24] THE QUARTZ-CRYSTAL MICROBALANCE AS BIOSENSOR - A STATUS-REPORT ON ITS FUTURE
    MINUNNI, M
    MASCINI, M
    GUILBAULT, GG
    HOCK, B
    ANALYTICAL LETTERS, 1995, 28 (05) : 749 - 764
  • [25] Quartz crystal microbalance biosensor design II.: Simulation of sample transport
    Jonsson, Mats
    Anderson, Henrik
    Lindberg, Ulf
    Aastrup, Teodor
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 21 - 26
  • [26] Development of a Quartz Crystal Microbalance Biosensor with Aptamers as Bio-recognition Element
    Yao, Chunyan
    Zhu, Tangyou
    Qi, Yongzhi
    Zhao, Yuhui
    Xia, Han
    Fu, Weiling
    SENSORS, 2010, 10 (06): : 5859 - 5871
  • [27] A novel assay for detecting canine parvovirus using a quartz crystal microbalance biosensor
    Kim, Yong Kwan
    Lim, Seong-In
    Choi, Sarah
    Cho, In-Soo
    Park, Eun-Hye
    An, Dong-Jun
    JOURNAL OF VIROLOGICAL METHODS, 2015, 219 : 23 - 27
  • [28] Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor
    Min, Hyun Jung
    Mina, Hansel A.
    Deering, Amanda J.
    Robinson, J. Paul
    Bae, Euiwon
    SENSORS, 2022, 22 (22)
  • [29] Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
    Yao, Chunyan
    Qu, Ling
    Fu, Weiling
    SENSORS, 2013, 13 (06): : 6946 - 6956
  • [30] A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing
    Ohlsson, Gabriel
    Langhammer, Christoph
    Zoric, Igor
    Kasemo, Bengt
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (08):