Real-time automated thickness measurement of the in vivo human tympanic membrane using optical coherence tomography

被引:51
|
作者
Hubler, Zita [1 ]
Shemonski, Nathan D. [2 ,3 ]
Shelton, Ryan L. [2 ]
Monroy, Guillermo L. [1 ,2 ]
Nolan, Ryan M. [2 ]
Boppart, Stephen A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Illinois, Dept Bioengn, Urbana, IL USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA
[4] Univ Illinois, Dept Internal Med, Urbana, IL USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Optical coherence tomography (OCT); otitis media (OM); ear infection; tympanic membrane (TM); real-time; automated;
D O I
10.3978/j.issn.2223-4292.2014.11.32
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear. Diagnosis and monitoring of OM is critical for successful management, but remains largely qualitative. Methods: We have developed an optical coherence tomography (OCT) system for high-resolution, depth-resolved, cross-sectional imaging of the TM and middle ear content, and for the quantitative assessment of in vivo TM thickness including the presence or absence of a middle ear biofilm. A novel algorithm was developed and demonstrated for automatic, real-time, and accurate measurement of TM thickness to aid in the diagnosis and monitoring of OM and other middle ear conditions. The segmentation algorithm applies a Hough transform to the OCT image data to determine the boundaries of the TM to calculate thickness. Results: The use of OCT and this segmentation algorithm is demonstrated first on layered phantoms and then during real-time acquisition of in vivo OCT from humans. For the layered phantoms, measured thicknesses varied by approximately 5 mu m over time in the presence of large axial and rotational motion. In vivo data also demonstrated differences in thicknesses both spatially on a single TM, and across normal, acute, and chronic OM cases. Conclusions: Real-time segmentation and thickness measurements of image data from both healthy subjects and those with acute and chronic OM demonstrate the use of OCT and this algorithm as a robust, quantitative, and accurate method for use during real-time in vivo human imaging.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [1] Imaging the Human Tympanic Membrane Using Optical Coherence Tomography In Vivo
    Djalilian, Hamid R.
    Ridgway, James
    Tam, Majestic
    Sepehr, Ali
    Chen, Zhongping
    Wong, Brian J. F.
    OTOLOGY & NEUROTOLOGY, 2008, 29 (08) : 1091 - 1094
  • [2] In Vivo Thickness of the Healthy Tympanic Membrane Determined by Optical Coherence Tomography
    Morgenstern, Joseph
    Kreusch, Theodor
    Golde, Jonas
    Steuer, Svea
    Ossmann, Steffen
    Kirsten, Lars
    Walther, Julia
    Zahnert, Thomas
    Koch, Edmund
    Neudert, Marcus
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : e256 - e262
  • [3] Measurement of Vibrating Tympanic Membrane in an In Vivo Mouse Model Using Doppler Optical Coherence Tomography
    Jeon, Deokmin
    Kim, Joon Ki
    Jeon, Mansik
    Kim, Jeehyun
    JOURNAL OF IMAGING, 2019, 5 (09)
  • [4] Preliminary Human Tympanic Membrane Thickness Data from Optical Coherence Tomography
    Buytaert, J.
    Van der Jeught, S.
    Ars, B.
    Podoleanu, A.
    Dirckx, J.
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES & SYSTEMS2 (OPTIMESS2012), 2013, : 75 - 84
  • [5] Automated Segmentation of Optical Coherence Tomography Images of the Human Tympanic Membrane Using Deep Learning
    Oghalai, Thomas P.
    Long, Ryan
    Kim, Wihan
    Applegate, Brian E.
    Oghalai, John S.
    ALGORITHMS, 2023, 16 (09)
  • [6] Doppler optical coherence tomography for the investigation of the human tympanic membrane ex vivo
    Walther, J.
    Burkhardt, A.
    Kirsten, L.
    Golde, J.
    Stoppe, T.
    Kemper, M.
    Bornitz, M.
    Zahnert, T.
    Koch, E.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S527 - +
  • [7] Investigation of the human tympanic membrane oscillation ex vivo by Doppler optical coherence tomography
    Burkhardt, Anke
    Kirsten, Lars
    Bornitz, Matthias
    Zahnert, Thomas
    Koch, Edmund
    JOURNAL OF BIOPHOTONICS, 2014, 7 (06) : 434 - 441
  • [8] Real-time in vivo colors Doppler optical coherence tomography
    Rollins, AM
    Yazdanfar, S
    Barton, JK
    Izatt, JA
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) : 123 - 129
  • [9] Automated detection and measurement of epidermal thickness using optical coherence tomography
    Weissman, J
    Hancewicz, T
    Kaplan, P
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2005, 52 (03) : P36 - P36
  • [10] In vivodynamic characterization of the human tympanic membrane using pneumatic optical coherence tomography
    Won, Jungeun
    Porter, Ryan G.
    Novak, Michael A.
    Youakim, Jon
    Sum, Ada
    Barkalifa, Ronit
    Aksamitiene, Edita
    Zhang, Anqi
    Nolan, Ryan
    Shelton, Ryan
    Boppart, Stephen A.
    JOURNAL OF BIOPHOTONICS, 2021, 14 (04)