Pocket mobile smartphone system for the point-of-care submandibular ultrasonography

被引:27
|
作者
Wojtczak, Jacek [1 ]
Bonadonna, Peter [2 ]
机构
[1] Univ Rochester, Sch Med & Dent, Dept Anesthesiol, Rochester, NY 14642 USA
[2] SUNY Monroe Community Coll, Paramed Program, Rochester, NY 14623 USA
来源
AMERICAN JOURNAL OF EMERGENCY MEDICINE | 2013年 / 31卷 / 03期
关键词
FOCUSED ASSESSMENT; TELE-ULTRASOUND; SONOGRAPHY; AIRWAY; TRAUMA;
D O I
10.1016/j.ajem.2012.09.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Focused ultrasonography of the airway may be useful in the prediction of difficult intubation. The wider use of sonography in quantitative airway assessment may depend on the availability of highly portable, inexpensive, and accurate ultrasound systems. Pocket-sized ultrasound devices are emerging as a useful tool for point-of-care ultrasonography. The aim of this study was to evaluate the suprahyoid airway of healthy volunteers using a smartphone-based ultrasound imaging system in comparison with a platform-based machine. Methods: Mobisante MobiUS SP1 system with 2 mechanical sector (3.5 and 7.5 MHz) probes was used to acquire images of the tongue and measure the diameter of the hyomental muscle in the mouth floor. In the same group of subjects, imaging and measurements were repeated using BK Medical Flex Focus 400 ultrasound system with linear (18 MHz) and curved 5 (MHz) transducers. The MobiUS system was also used to image plastic cylinders and procedure needles embedded in tofu bars. Outside diameters of cylinders were measured using digital calipers and sonography. Results: The mean diameter of the hyomental muscle in 10 healthy volunteers was 7.22 +/- 1.6 mm using BK 18 MHzprobe, 7.11 +/- 1.7mmusing MobiUS 7.5 MHz probe, and 7.84 +/- 2 mm using MobiUS 3.5 MHz probe. These means were not statistically different (BK vs Mo 7.5, P = .74, and BK vs Mo 3.5, P = .13). The mean outside diameter of plastic cylinders measured with digital calipers was 10.1 +/- 0.2 mm (n = 5) vs 9.8 +/- 0.3 mm and 10.2 +/- 0.2 mm using 3.5 and 7.5 MHz probes, respectively. These means were not statistically different (calipers vs Mo 3.5, P = .16 and calipers vs Mo 7.5, P = .39). Conclusion: Mobisante MobiUS system was able to acquire clinically useful images of the suprahyoid airway and muscular architecture in the mouth floor and allowed accurate measurements of linear distances. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 50 条
  • [11] Point-of-care ultrasonography in pediatrics
    Parri, Niccolo
    Berant, Ron
    Giacalone, Martina
    Corsini, Iuri
    Titomanlio, Luigi
    Connolly, Jim
    Kwan, Charisse
    Teng, David
    PEDIATRIC RADIOLOGY, 2021, 51 (07) : 1271 - 1272
  • [12] Feasibility and accuracy of point-of-care pocket-size ultrasonography performed by medical students
    Andersen, Garrett Newton
    Viset, Annja
    Mjolstad, Ole Christian
    Salvesen, Oyvind
    Dalen, Havard
    Haugen, Bjorn Olav
    BMC MEDICAL EDUCATION, 2014, 14
  • [13] Feasibility and accuracy of point-of-care pocket-size ultrasonography performed by medical students
    Garrett Newton Andersen
    Annja Viset
    Ole Christian Mjølstad
    Øyvind Salvesen
    Håvard Dalen
    Bjørn Olav Haugen
    BMC Medical Education, 14
  • [14] Point-of-Care Ultrasonography, Primary Care, and Prudence
    Tanael, Michael
    ANNALS OF INTERNAL MEDICINE, 2020, 173 (08) : 650 - +
  • [15] Smartphone chloridometer for point-of-care applications
    Zhang, Chenji
    Kim, Jimin P.
    Creer, Michael
    Yang, Jian
    Liu, Zhiwen
    ULTRAFAST NONLINEAR IMAGING AND SPECTROSCOPY V, 2017, 10380
  • [16] Point-of-care colorimetric detection with a smartphone
    Shen, Li
    Hagen, Joshua A.
    Papautsky, Ian
    LAB ON A CHIP, 2012, 12 (21) : 4240 - 4243
  • [17] Smartphone-based mobile biosensors for the point-of-care testing of human metabolites
    Zhang, Meiying
    Cui, Xin
    Li, Nan
    MATERIALS TODAY BIO, 2022, 14
  • [18] CURRENT CONCEPTS Point-of-Care Ultrasonography
    Moore, Christopher L.
    Copel, Joshua A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (08): : 749 - 757
  • [19] Pneumopericardium diagnosis by point-of-care ultrasonography
    Bobbia, Xavier
    Claret, Pierre Geraud
    Muller, Laurent
    de La Coussaye, Jean Emmanuel
    JOURNAL OF CLINICAL ULTRASOUND, 2013, 41 (04) : 235 - 237
  • [20] Basics of Point-of-Care Lung Ultrasonography
    Buda, Natalia
    Mendrala, Konrad
    Skoczynski, Szymon
    Pasquier, Mathieu
    Mazur, Piotr
    Garcia, Elena
    Darocha, Tomasz
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 389 (21):