Signal coding for cochlear implants: The effects of pulse width

被引:0
|
作者
McKay, C
McDermott, H
机构
来源
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biphasic current pulses are used in cochlear implants to code important features of acoustic signals. The duration (width) of each pulse has been used as one of the electrical parameters which code acoustic intensity (and thus loudness). Our psychophysical experiments show that altering the pulse width causes changes in perception other than loudness, that may be the result of changes to the population of activated neurons or its spatial pattern. Thus, pulse width may be one feature which can be utilised in future signal processing strategies in order to more finely manipulate the perception of important features of speech.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 50 条
  • [41] A psychoacoustic "NofM"-type speech coding strategy for cochlear implants
    Nogueira, W
    Büchner, A
    Lenarz, T
    Edler, B
    EURASIP JOURNAL ON APPLIED SIGNAL PROCESSING, 2005, 2005 (18) : 3044 - 3059
  • [42] The Precision of Neuronal Coding in the Auditory Brainstem and Implications for Cochlear Implants
    Wang, H.
    Holmberg, M.
    Hemmert, W.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 68 - +
  • [43] A bio-inspired coding (BIC) strategy for cochlear implants
    Tabibi, Sonia
    Kegel, Andrea
    Lai, Wai Kong
    Dillier, Norbert
    HEARING RESEARCH, 2020, 388
  • [44] Better Temporal Neural Coding with Cochlear Implants in Awake Animals
    Chung, Yoojin
    Hancock, Kenneth E.
    Nam, Sung-Il
    Delgutte, Bertrand
    BASIC ASPECTS OF HEARING: PHYSIOLOGY AND PERCEPTION, 2013, 787 : 353 - 361
  • [45] Development of a temporal fundamental frequency coding strategy for cochlear implants
    Vandali, Andrew E.
    van Hoesel, Richard J. M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (06): : 4023 - 4036
  • [46] Better place-coding of the fundamental frequency in cochlear implants
    Geurts, L
    Wouters, J
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (02): : 844 - 852
  • [47] Cochlear implants: the effects of age on outcomes
    Spitzer E.R.
    Waltzman S.B.
    Expert Review of Medical Devices, 2023, 20 (12) : 1131 - 1141
  • [48] Coding of Electric Pulse Trains Presented through Cochlear Implants in the Auditory Midbrain of Awake Rabbit: Comparison with Anesthetized Preparations
    Chung, Yoojin
    Hancock, Kenneth E.
    Nam, Sung-Il
    Delgutte, Bertrand
    JOURNAL OF NEUROSCIENCE, 2014, 34 (01): : 218 - 231
  • [49] SIGNAL TRANSDUCTION WITH DIFFERENTIAL PULSE WIDTH MODULATION
    LEE, SY
    LI, YT
    PASTAN, HL
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1970, IE17 (02): : 39 - &
  • [50] Integration of Pulse Trains in Humans and Guinea Pigs with Cochlear Implants
    Zhou, Ning
    Kraft, Casey T.
    Colesa, Deborah J.
    Pfingst, Bryan E.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2015, 16 (04): : 523 - 534