An improved method for measuring vapor pressure by DSC with automated pressure control

被引:28
|
作者
Casserino, M [1 ]
Blevins, DR [1 ]
Sanders, RN [1 ]
机构
[1] ALBEMARLE CORP,BATON ROUGE,LA 70898
关键词
vapour pressure; DSC; thermal analysis;
D O I
10.1016/0040-6031(96)02923-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
Vapor pressure measurements are necessary for a wide range of applications in the chemical industry. Traditional methods require 10-30 mi of sample, 6-8 h of operator time, and multiple measurements for high precision data. With a modification to the pressure differential scanning calorimeter cell, use of hermetic-type pans with pin-holed lids, and the addition of a pressure controller, vapor pressure measurements from 5-760 torr can be obtained. These measurements use less than 1 mi of sample, take about 2 h of operator time, and achieve high precision data on a single set of measurements.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [41] AN IMPROVED INDIRECT MEASURING METHOD FOR ARTERIAL BLOOD-PRESSURE IN UNANESTHETIZED RATS
    SUGANO, S
    HIROSE, H
    SAWAZAKI, H
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1982, 44 (01): : 133 - 135
  • [42] APPLICATIONS WITH PRESSURE DSC
    WIEDEMANN, HG
    BOLLER, A
    AMERICAN LABORATORY, 1992, 24 (06) : 52 - &
  • [43] Measuring and predicting the vapor pressure of gasoline containing oxygenates
    Gaspar, Daniel J.
    Phillips, Steven D.
    Polikarpov, Evgueni
    Albrecht, Karl O.
    Jones, Susanne B.
    George, Anthe
    Landera, Alexander
    Santosa, Daniel M.
    Howe, Daniel T.
    Baldwin, Anna G.
    Bays, J. Timothy
    FUEL, 2019, 243 : 630 - 644
  • [44] A glass wool cell for measuring aqueous vapor pressure
    Edlefsen, NE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1933, 4 (06): : 345 - 346
  • [45] In defense of vapor pressure osmometry for measuring molecular weight
    Wiehe, Irwin A.
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2007, 28 (03) : 431 - 435
  • [46] On measuring the instantaneous blood pressure in an artery via the tissue control method
    Lin, Albert Chin-Yuh
    Huang, Huang-Nan
    Su, Yi-Chang
    Shiu, Chih-Yuan
    Wang, Yao-Horng
    Chiang, Hao-Cheng
    Tung, Hung
    Lin, Jui-Shan
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (08) : 937 - 951
  • [47] AN IMPROVED BALLOON SYSTEM FOR MEASURING INTRAESOPHAGEAL PRESSURE
    SCHILDER, DP
    HYATT, RE
    FRY, DL
    JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (06) : 1057 - 1058
  • [48] The influence of the method of data analysis on the reported accuracy of automated blood pressure measuring devices
    Braam, RL
    Thien, T
    JOURNAL OF HYPERTENSION, 2001, 19 (10) : 1765 - 1767
  • [49] A simple automated method for measuring pressure-volume curves during mechanical ventilation
    Lu, Q
    Vieira, SRR
    Richecoeur, J
    Puybasset, L
    Kalfon, P
    Coriat, P
    Rouby, JJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (01) : 275 - 282
  • [50] Automated postoperative blood pressure control
    Hang Zheng
    Kuanyi Zhu
    Journal of Control Theory and Applications, 2005, 3 (3): : 207 - 212