Applications of Computational Fluid Dynamics in The Design and Rehabilitation of Nonstandard Vertical Slot Fishways

被引:18
|
作者
Sanagiotto, Daniela Guzzon [1 ]
Rossi, Julia Brusso [1 ]
Bravo, Juan Martin [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Pesquisas Hidraul, Ave Bento Goncalves 9500, BR-91501970 Porto Alegre, RS, Brazil
来源
WATER | 2019年 / 11卷 / 02期
关键词
fish pass; vertical slot fishway; computational fluid dynamics; ecohydraulics; hydraulic design; POOL-TYPE FISHWAYS; SWIMMING PERFORMANCE; TURBULENT-FLOW; NEOTROPICAL FISH; PASSAGE; HYDRAULICS; SIMULATION; HABITAT; MODEL; FIELD;
D O I
10.3390/w11020199
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Vertical slot fishways are increasingly common structures for the passage of a wide variety of migratory fish and contribute to the maintenance of fish diversity in fragmented rivers. These structures are designed with several geometric arrangements and, consequently, flow patterns through them can be shaped to present suitable characteristics for the fish species. To aid in the design of vertical slot fishways, a three-dimensional numerical model was used to simulate the flow for different geometric configurations. An existing vertical slot fishway with nonstandard dimensions was initially modeled and validated. This geometry was used as a reference design. Modifications to the reference design, such as the insertion of cylinders, changes in the baffle shape and position of the vertical slots, as possible rehabilitation measures, were proposed and tested. In summary, five different designs were evaluated with several slopes, totaling 17 geometries. Hydraulic parameters, flow patterns, maximum velocities, velocity fields and turbulence kinetic energy in the pools were analyzed. The results indicate that the maximum velocity values were between 9% and 68% higher than those obtained by the theoretical equation. This indicates that maximum velocities can be underestimated for nonstandard vertical slot fishways if a simplified evaluation is conducted. The insertion of cylinders in the region close to the slot reduces the maximum velocity up to 8.2%. The positioning of the vertical slots on alternating sides increases the maximum values of turbulence kinetic energy and the regions subjected to higher values. However, this configuration provided greater energy dissipation and reduction of velocities by up to 27%. Thus, modifications in nonstandard vertical slot fishways can be useful in future design or rehabilitation of existing structures in order to provide velocities and turbulence more friendly for a higher number of fish species.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Practical applications of computational fluid dynamics to wind design of high-rise buildings
    Kim, Min Kyu
    Kang, Soonpil
    Kang, Thomas H. -K.
    WIND AND STRUCTURES, 2024, 39 (04) : 287 - 304
  • [32] Computational fluid dynamics (cfd) in building design
    Tang, D
    INNOVATION IN CIVIL AND CONSTRUCTION ENGINEERING, 1997, : 91 - 98
  • [33] Stent Design Using Computational Fluid Dynamics
    Seo, Taewon
    Kim, Taedong
    Barakat, Abdul
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2005, 29 (09) : 1042 - 1048
  • [34] Heave plate design with computational fluid dynamics
    Holmes, S
    Bhat, S
    Beynet, P
    Sablok, A
    Prislin, I
    JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01): : 22 - 28
  • [35] COMPUTATIONAL FLUID DYNAMICS APPLICABLE TO CLOTH DESIGN
    Cunha, Ana M. F.
    Teixeira, Jose C. F.
    Teixeira, Senhorinha F. C. F.
    IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 233 - 241
  • [36] DESIGN OPTIMISATION USING COMPUTATIONAL FLUID DYNAMICS
    Green, Johnathan
    Naval Architect, 2023, : 50 - 53
  • [37] Impact of computational fluid dynamics in aircraft design
    Tinoco, E.N.
    Canadian Aeronautics and Space Journal, 1998, 44 (03): : 132 - 143
  • [38] The use of computational fluid dynamics in inhaler design
    Ruzycki, Conor A.
    Javaheri, Emadeddin
    Finlay, Warren H.
    EXPERT OPINION ON DRUG DELIVERY, 2013, 10 (03) : 307 - 323
  • [39] Shape Optimization of Vertical Profiler using Computational Fluid Dynamics
    Kishor, Anand
    Thangavel, C.
    Muthuvel, P.
    Sudhakar, Tata
    2015 IEEE UNDERWATER TECHNOLOGY (UT), 2015,
  • [40] Computational fluid dynamics modelling of microclimate for a vertical agrivoltaic system
    Zainali, Sebastian
    Qadir, Omar
    Parlak, Sertac Cem
    Lu, Silvia Ma
    Avelin, Anders
    Stridh, Bengt
    Campana, Pietro Elia
    ENERGY NEXUS, 2023, 9