In vitro evaluation of current thoracic aortic stent-grafts for real-time MR-guided placement

被引:16
|
作者
Eggebrecht, H
Zenge, M
Ladd, ME
Erbel, R
Quick, HH
机构
[1] Univ Duisburg Essen, Dept Cardiol, D-45122 Essen, Germany
[2] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, W German Heart Ctr Essen, D-45122 Essen, Germany
关键词
magnetic resonance imaging; real-time MRI; MR guidance; thoracic aorta; stent-graft; susceptibility artifact;
D O I
10.1583/05-1707.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. Methods: Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution Tjweighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. Results: Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel-based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. Conclusion: The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [21] Real-time MR-guided catheterization of the coronary arteries in an animal model
    Buecker, A
    Spuentrup, E
    Pfeffer, J
    Schmitz-Rode, T
    Schaeffter, T
    Guenther, RW
    RADIOLOGY, 2001, 221 : 416 - 416
  • [22] Real-time MR-guided Retrieval of Inferior Vena Cava Filters: An in Vitro and Animal Model Study
    Shih, Ming-Chen Paul
    Rogers, Walter J.
    Bonatti, Hugo
    Hagspiel, Klaus D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (06) : 843 - 850
  • [23] Evaluation of Real-Time Cine Imaging During MLC and Gantry Motion for MR-Guided Radiation Therapy
    Kielbasa, J.
    Meeks, S.
    Kelly, P.
    Willoughby, T.
    Zeidan, O.
    Shah, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E615 - E615
  • [24] Real-time inversion recovery for infarct visualization during MR-guided interventions
    Adrienne E Campbell-Washburn
    Toby Rogers
    Jonathan R Mazal
    Michael S Hansen
    Robert J Lederman
    Anthony Z Faranesh
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [25] A system for advanced real-time visualization and monitoring of MR-guided thermal ablations
    Rothgang, Eva
    Gilson, Wesley D.
    Hornegger, Joachim
    Lorenz, Christine H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [26] MR-guided joint puncture and real-time MR-assisted contrast media application
    Trattnig, S
    Breitenseher, M
    Pretterklieber, M
    Kontaxis, G
    Rand, T
    Helbich, T
    Imhof, H
    ACTA RADIOLOGICA, 1997, 38 (06) : 1047 - 1049
  • [27] Real-Time Active MR-Tracking of Metallic Stylets in MR-Guided Radiation Therapy
    Wang, Wei
    Dumoulin, Charles L.
    Viswanathan, Akila N.
    Tse, Zion T. H.
    Mehrtash, Alireza
    Loew, Wolfgang
    Norton, Isaiah
    Tokuda, Junichi
    Seethamraju, Ravi T.
    Kapur, Tina
    Damato, Antonio L.
    Cormack, Robert A.
    Schmidt, Ehud J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1803 - 1811
  • [28] Magnetic resonance-guided placement of aortic stents grafts:: Feasibility with real-time magnetic resonance fluoroscopy
    Mahnken, AH
    Chalabi, K
    Jalali, F
    Günther, RW
    Buecker, A
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (02) : 189 - 195
  • [29] MR-guided cholecystostomy: Assessment of biplanar, real-time needle tracking in three pigs
    Susanne C. Göhde
    Thomas Pfammatter
    Paul Steiner
    Peter Erhart
    Benjamin J. Romanowski
    Jörg F. Debatin
    CardioVascular and Interventional Radiology, 1997, 20 : 295 - 299
  • [30] MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU
    Zaporzan, Benjamin
    Waspe, Adam C.
    Looi, Thomas
    Mougenot, Charles
    Partanen, Ari
    Pichardo, Samuel
    JOURNAL OF THERAPEUTIC ULTRASOUND, 2013, 1