Blood pressure evaluation using sphygmomanometry assisted by arterial pulse waveform detection by fiber Bragg grating pulse device

被引:29
|
作者
Sharath, Umesh [1 ]
Sukreet, Raju [2 ]
Apoorva, Girish [2 ]
Asokan, Sundarrajan [1 ,3 ,4 ]
机构
[1] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, Karnataka, India
[2] Natl Inst Mental Hlth & Neurosci, Bangalore 560029, Karnataka, India
[3] Indian Inst Sci, Appl Photon Initiat, Bangalore 560012, Karnataka, India
[4] Robert Bosch Ctr Cyber Phys Syst, Bangalore 560012, Karnataka, India
关键词
fiber Bragg grating sensor; fiber Bragg grating pulse device; arterial pulse waveform; blood pressure;
D O I
10.1117/1.JBO.18.6.067010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a blood pressure evaluation methodology by recording the radial arterial pulse waveform in real time using a fiber Bragg grating pulse device (FBGPD). Here, the pressure responses of the arterial pulse in the form of beat-to-beat pulse amplitude and arterial diametrical variations are monitored. Particularly, the unique signatures of pulse pressure variations have been recorded in the arterial pulse waveform, which indicate the systolic and diastolic blood pressure while the patient is subjected to the sphygmomanometric blood pressure examination. The proposed method of blood pressure evaluation using FBGPD has been validated with the auscultatory method of detecting the acoustic pulses (Korotkoff sounds) by an electronic stethoscope. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Nonlinearly Chirped Microwave Pulse Generation Using A Spatially Discrete Chirped Fiber Bragg Grating
    Wang, Chao
    Yao, Jianping
    MWP: 2009 INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS, 2009, : 177 - 180
  • [42] NONINVASIVE DETECTION OF PROFOUND ARTERIAL DESATURATIONS USING A PULSE OXIMETRY DEVICE
    MIHM, FG
    HALPERIN, BD
    ANESTHESIOLOGY, 1985, 62 (01) : 85 - 87
  • [43] Basis of Monitoring Central Blood Pressure and Hemodynamic Parameters by Peripheral Arterial Pulse Waveform Analyses
    Miyashita, Hiroshi
    Katsuda, Shin-ichiro
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 221 - 224
  • [44] Wearable Side-Polished Fiber Bragg Grating Sensor For Pulse Wave and Throat Sound Detection
    Li, Cheng
    Peng, Xiaobin
    Zhang, Hui
    Wang, Chao
    Fan, Shangchun
    Cao, Shaoqing
    2017 IEEE SENSORS, 2017, : 708 - 710
  • [45] Blood Pressure and Heart Rate Measurements Using Fiber Bragg Grating Sensor with Optical Power Detection Scheme
    Wang, Yu-Jie
    Wang, Likarn
    SENSORS, 2025, 25 (07)
  • [46] EVALUATION OF A NEW MONITORING DEVICE FOR ARTERIAL BLOOD-PRESSURE AND HEART-RATE MEASUREMENT BY AUTOMATIC SPHYGMOMANOMETRY
    CHASTONAY, P
    MOREL, D
    FORSTER, A
    SUTER, PM
    ANASTHESIE INTENSIVTHERAPIE NOTFALLMEDIZIN, 1982, 17 (06): : 348 - 350
  • [47] Prototype of Wearable Device for Blood Pressure using Pulse Transit Time
    Bunkum, Manao
    Wanluk, Nutthanan
    Visitsattapongse, Sarinporn
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [48] Measuring blood pressure by a cuffless device using the pulse transit time
    Patzak, Andreas
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2021, 8
  • [49] Fiber-Based SBS Pulse Compression Using Bragg Grating Reflection Feedback of Stokes Seed
    Matsumoto, Masayuki
    Miyashita, Genya
    Kiso, Hitoshi
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,
  • [50] Automated Detection of Pulse Using Continuous Invasive Arterial Blood Pressure in Patients During Cardiopulmonary Resuscitation
    Urteaga, Jon
    Elola, Andoni
    Aramendi, Elisabete
    Irusta, Unai
    Berve, Per Olav
    Wik, Lars