Adaptive image approximation by linear splines over locally optimal Delaunay triangulations

被引:20
|
作者
Demaret, L [1 ]
Iske, A
机构
[1] GSF, Inst Biomath & Biometrie, D-85764 Neuherberg, Germany
[2] Univ Hamburg, Dept Math, D-20146 Hamburg, Germany
关键词
adaptive thinning algorithms; Delaunay triangulations; image approximation; linear splines; local optimization;
D O I
10.1109/LSP.2006.870358
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Locally optimal Delaunay triangulations are constructed to improve previous image approximation schemes. Our construction relies on a local optimization procedure, termed exchange. The efficient implementation of the exchange algorithm is addressed, and its complexity is discussed. The good performance of our improved image approximation is illustrated by numerical comparisons.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 27 条
  • [21] LOCALLY-OPTIMAL ADAPTIVE-CONTROL OF A LINEAR STOCHASTIC OBJECT WITH A NONMEASURABLE STATE
    KOGAN, MM
    NEYMARK, YI
    JOURNAL OF COMPUTER AND SYSTEMS SCIENCES INTERNATIONAL, 1995, 33 (03) : 1 - 6
  • [22] Single image super-resolution using locally adaptive multiple linear regression
    Yu, Soohwan
    Kang, Wonseok
    Ko, Seungyong
    Paik, Joonki
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (12) : 2264 - 2275
  • [23] Sample based 3D face reconstruction from a single frontal image by adaptive locally linear embedding
    Jian Zhang
    Yue-ting Zhuang
    Journal of Zhejiang University-SCIENCE A, 2007, 8 : 550 - 558
  • [25] Sample based 3D face reconstruction from a single frontal image by adaptive locally linear embedding
    Zhang Jian
    Zhuang Yue-ting
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2007, 8 (04): : 550 - 558
  • [26] Computationally Simple MMSE (A-Optimal) Adaptive Beam-Pattern Design for MIMO Active Sensing Systems via a Linear-Gaussian Approximation
    Herbert, Steven
    Hopgood, James R.
    Mulgrew, Bernard
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2018, 66 (18) : 4935 - 4945
  • [27] 45 or 50 Gy, Which is the Optimal Radiotherapy Pelvic Dose in Locally Advanced Cervical Cancer in the Perspective of Reaching Magnetic Resonance Image-guided Adaptive Brachytherapy Planning Aims?
    Mazeron, R.
    Petit, C.
    Rivin, E.
    Limkin, E.
    Dumas, I.
    Maroun, P.
    Annede, P.
    Martinetti, F.
    Seisen, T.
    Lefkopoulos, D.
    Chargari, C.
    Haie-Meder, C.
    CLINICAL ONCOLOGY, 2016, 28 (03) : 171 - 177