摘要
Small-animal irradiators are widely used in oncologic research, and many experiments use mice to mimic radiation treatments in humans. To improve fractionated high-precision irradiation in mice with orthotopic pancreatic tumors, we evaluated 3 positioning methods: no positioning aid, skin marker, and immobilization devices (immobilization masks). We retrospectively evaluated the translation vector needed for optimal tumor alignment (by shifting the mouse in left-right, in cranio-caudal, and in anterior-posterior direction) on cone-beam CT from our small-animal radiotherapy system. Of the 3 methods, the skin marker method yielded the smallest mean translation vector (3.8 mm) and was the most precise method overall for most of the mice. In addition, the skin marker method required supplemental rotation (that is, roll, pitch, and yaw) for optimal tumor alignment only half as often as positioning without a positioning aid. Finally, the skin marker method had the highest scores for the quality of the fusion results. Overall, we preferred the skin marker method over the other 2 positioning methods with regard to optimal treatment planning and radiotherapy in an orthotopic mouse model of pancreatic cancer.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 50 条
  • [21] Effects of High-LET Radiotherapy on Orthotopic Glioma Mouse Model
    Shimokawa, Takashi
    Morioka, Takamitsu
    CANCER SCIENCE, 2023, 114 : 686 - 686
  • [22] Complementarity of ultrasound and fluorescence imaging in an orthotopic mouse model of pancreatic cancer
    Cynthia S Snyder
    Sharmeela Kaushal
    Yuko Kono
    Hop S Tran Cao
    Robert M Hoffman
    Michael Bouvet
    BMC Cancer, 9
  • [23] Luteolin and Gemcitabine Protect Against Pancreatic Cancer in an Orthotopic Mouse Model
    Johnson, Jodee L.
    Dia, Vermont P.
    Wallig, Matthew
    de Mejia, Elvira Gonzalez
    PANCREAS, 2015, 44 (01) : 144 - 151
  • [24] Complementarity of ultrasound and fluorescence imaging in an orthotopic mouse model of pancreatic cancer
    Snyder, Cynthia S.
    Kaushal, Sharmeela
    Kono, Yuko
    Cao, Hop S. Tran
    Hoffman, Robert M.
    Bouvet, Michael
    BMC CANCER, 2009, 9
  • [25] HIGH-PRECISION CONFORMAL FRACTIONATED RADIOTHERAPY IS EFFECTIVE IN ACHIEVING REMISSION IN PATIENTS WITH ACROMEGALY AFTER FAILED TRANSSPHENOIDAL SURGERY
    Patt, Hiren
    Jalali, Rakesh
    Yerawar, Chaitanya
    Khare, Shruti
    Gupta, Tejpal
    Goel, Atul
    Lila, Anurag
    Bandgar, Tushar
    Shah, Nalini S.
    ENDOCRINE PRACTICE, 2016, 22 (02) : 162 - 172
  • [26] Low Dose Metronomic Gemcitabine has High Antimetastatic Efficacy in an Orthotopic Mouse Model of Pancreatic Cancer
    Cao, H. S. Tran
    Bouvet, M.
    Romney, E.
    Kaushal, S.
    Keleman, A.
    Kim, G.
    Fruehauf, J.
    Imagawa, D. K.
    Hoffman, R. M.
    Katz, M. H.
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 : S65 - S65
  • [27] Optimization of an Orthotopic Mouse Model of Pancreatic Cancer to Simulate Liver Metastasis and Cancer Cachexia
    Wang, David J.
    Spadafora, Victoria
    Pryce, Benjamin R.
    Oles, Alexander
    Talbert, Erin E.
    Ostrowski, Micheal C.
    Guttridge, Denis C.
    CANCER RESEARCH, 2024, 84 (17)
  • [28] A Robust Approach to Model Colored Noise for Low-cost High-precision Positioning
    Gao, Yuting
    Gao, Yang
    Liu, Baoyu
    Du, Yuan
    Wane, Jin
    PROCEEDINGS OF THE 32ND INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS+ 2019), 2019, : 3686 - 3694
  • [29] Dose distributions of high-precision radiotherapy treatment: A comparison between the CyberKnife and TrueBeam systems
    Ito, M.
    Kawamura, T.
    Mori, Y.
    Mori, T.
    Takeuchi, A.
    Oshima, Y.
    Nakamura, K.
    Aoyama, T.
    Kaneda, N.
    Ishiguchi, T.
    Mizumatsu, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 395 - 402
  • [30] Histopathological Tumor and Normal Tissue Responses after 3D-Planned Arc Radiotherapy in an Orthotopic Xenograft Mouse Model of Human Pancreatic Cancer
    Dobiasch, Sophie
    Kampfer, Severin
    Steiger, Katja
    Schilling, Daniela
    Fischer, Julius C.
    Schmid, Thomas E.
    Weichert, Wilko
    Wilkens, Jan J.
    Combs, Stephanie E.
    CANCERS, 2021, 13 (22)