Macrocycle based membrane sensors for the determination of cobalt(II) ions

被引:227
|
作者
Jain, AK
Gupta, VK
Singh, LP
Khurana, U
机构
[1] Department of Chemistry, University of Roorkee
关键词
ion sensors; cobalt-selective electrodes; membrane electrodes;
D O I
10.1039/a608421d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(vinyl chloride) (PVC) based membranes of macrocycles, 5,7,7,12,14,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene diperchlorate (I), 3,5,7,7,10,12,14,14-octamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene diperchlorate (II) and 5,10,15,20-tetraphenylporphyrin (III) with sodium tetraphenylborate (STB) as an anion excluder and dibutyl phthalate (DBP), dioctyl phthalate (DOP), dibutyl butylphosphonate (DBBP) and 1-chloronaphthalene (CN) as plasticizing solvent mediators were prepared and investigated as Co2+-selective electrodes, The best performance was observed with the membrane having the composition III-PVC-STB-DBP in the ratio 3:8:1:8, which works well over a wide concentration range (8.0 x 10(-)6)-1.0 x 10(-1) mol l(-1)) with a Nernstian slope of 29.0 mV per decade of activity between pH 2.8 and 7.3, This electrode shows a fast response time of 20 s and was used over a period of 4 months with good reproducibility (s = 0.4 mV), The selectivity coefficient values of the order of 0.01 for mono-, di- and trivalent cations indicate excellent selectivity for Co2+ over a large number of cations. Anions such as Cl- and SO42- do not interfere and the electrode also works satisfactorily in a partially non-aqueous medium, The sensor has been used as an indicator electrode in the potentiometric titration of Co2+ with EDTA.
引用
收藏
页码:583 / 586
页数:4
相关论文
共 50 条
  • [31] Study of the membrane morphology and investigation of sensitivity to ions for sensors based on calixarenes
    BenChaabane, R
    Gamoudi, M
    Guillaud, G
    Jouve, C
    Lamartine, R
    Bouazizi, A
    Marref, H
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 31 (1-2) : 41 - 44
  • [32] H-point standard addition method for simultaneous determination of cobalt(II) and zinc(II) ions
    Pouretedal, H. R.
    Asefi, M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2007, 4 (04) : 503 - 509
  • [33] H-point standard addition method for simultaneous determination of cobalt(II) and zinc(II) ions
    H. R. Pouretedal
    M. Asefi
    Journal of the Iranian Chemical Society, 2007, 4 : 503 - 509
  • [34] H-point Standard Addition Method for Simultaneous Determination of Cobalt(II) and Zinc(II) Ions
    Pouretedal, H. R.
    Asefi, M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2008, 5 (04) : 546 - 552
  • [35] H-point standard addition method for simultaneous determination of cobalt(II) and zinc(II) ions
    H. R. Pouretedal
    M. Asefi
    Journal of the Iranian Chemical Society, 2008, 5 : 546 - 552
  • [36] Two macrocycle-based sensors for anions sensing
    Yingjie Liu
    Zhixiang Zhao
    Ran Huo
    Qingxiang Liu
    Scientific Reports, 9
  • [37] Two macrocycle-based sensors for anions sensing
    Liu, Yingjie
    Zhao, Zhixiang
    Huo, Ran
    Liu, Qingxiang
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [38] Macrocycle carriers for separation of metal ions in liquid membrane processes - a review
    Walkowlak, Wladyslaw
    Kozlowski, Cezary A.
    DESALINATION, 2009, 240 (1-3) : 186 - 197
  • [39] Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions
    Pouretedal, HR
    Keshavarz, MH
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (01) : 28 - 31
  • [40] Application of cobalt (II) ions and iron (II) ions for hydrogen evolution reactions
    Quach, Qui
    Robertson, Elizabeth
    Messegee, Zachary
    Abdel-Fattah, Tarek
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254