Effect of different disinfectant methods on the initial microtensile bond strength of a self-etch adhesive to dentin

被引:23
|
作者
Dalkilic, Evrim Eliguzeloglu [1 ]
Arisu, Hacer Deniz [2 ]
Kivanc, Bagdagul Helvacioglu [3 ]
Uctasli, Mine Betul [2 ]
Omurlu, Huma [2 ]
机构
[1] Yuzuncu Yil Univ, Dept Restorat Dent, Fac Dent, TR-65080 Van, Turkey
[2] Gazi Univ, Dept Restorat Dent, Fac Dent, TR-06500 Ankara, Turkey
[3] Gazi Univ, Dept Endodont, Fac Dent, TR-06500 Ankara, Turkey
关键词
Ozone; Nd:YAG laser; Microtensile; Bond strength; Chlorhexidine; NDYAG LASER IRRADIATION; CARIOUS DENTIN; YAG LASER; IN-VITRO; OZONE; ENAMEL; CARIES; RESTORATIONS; SYSTEMS; CHLORHEXIDINE;
D O I
10.1007/s10103-011-0987-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this in vitro study was to evaluate the effect of different disinfection methods on the initial microtensile bond strength of a two-step, self-etch adhesive to dentin. Twenty mandibular molars were sectioned parallel to the occlusal plane to expose the mid-coronal dentin. All of the teeth were divided into four groups (n = 5 per group): (1) in group OZ, the dentin surfaces were exposed to ozone gas from the Ozonytron X delivery system (OzonyTron X-Bioozonix, Munich, Germany), (2) in group ND, the dentin surfaces were irradiated with an Nd:YAG laser (Pulsmaster 600 IQ, American Dental Technologies, U.S.), (3) in group CHX, the dentin surfaces were treated with a 2% chlorhexidine solution, and (4) in the control group, no treatment was applied. In all of the groups, the teeth were restored with Clearfil SE Bond (Kuraray, Tokyo, Japan) and Clearfil Majesty Posterior (Kuraray, Tokyo, Japan), according to the manufacturer's instructions. The teeth were sectioned perpendicular to the bonded surface (surface area of approximately 1 mm(2)). Thus, six to seven specimens were obtained from each tooth, and a total of 34 specimens were analyzed in each group. The specimens were attached to the microtensile test machine (Micro Tensile Tester, T-61010 K, Bisco, U.S.). The data was analyzed using the one-way analysis of variance (ANOVA) and Tukey test (p < 0.05). Fracture modes of each specimen were determined using a stereomicroscope (SZ-PT Olympus, Tokyo, Japan) and a scanning electron microscope (SEM). The lowest bond strength occurred in the OZ group. Significant differences were determined only between group OZ and the other groups (group ND, group CHX, and control group) (p < 0.05). In conclusion, although ozone decreased the microtensile bond strength of the self-etch adhesive system to dentin, the Nd:YAG laser and 2% chlorhexidine did not change the microtensile bond strength so in context of the present study it would appear that the Nd:YAG laser and 2% chlorhexidine may be used as pre-restorative sterilization procedures on the dentin prior to the application of a two-step, self-etch adhesive.
引用
收藏
页码:819 / 825
页数:7
相关论文
共 50 条
  • [21] Influence of Different Pulse Durations of Er:YAG Laser Based on Variable Square Pulse Technology on Microtensile Bond Strength of a Self-Etch Adhesive to Dentin
    Baraba, Anja
    Dukic, Walter
    Chieffi, Nicoletta
    Ferrari, Marco
    Anic, Ivica
    Miletic, Ivana
    PHOTOMEDICINE AND LASER SURGERY, 2013, 31 (03) : 116 - 124
  • [22] Effect of chlorhexidine on the shear bond strength of self-etch adhesives to dentin
    Chaharom, Mohammad Esmaeel Ebrahimi
    Ajami, Amir Ahmad
    Kimyai, Soodabeh
    Abbasi, Ahmad
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (49): : 10054 - 10057
  • [23] Microtensile bond strength to dentin and enamel of self-etch vs. etch-and-rinse modes of universal adhesives
    Cruz, Joana
    Sousa, Bernardo
    Coito, Catarina
    Lopes, Manuela
    Vargas, Marcos
    Cavalheiro, Alexandre
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (04): : 174 - 182
  • [24] Microtensile bond strength of etch-and-rinse and self-etch adhesive systems to demineralized dentin after the use of a papain-based chemomechanical method
    Gianini, Renato Jose
    Botelho do Amaral, Flavia Lucisano
    Florio, Flavia Martao
    Basting, Roberta Tarkany
    AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (01): : 23 - 28
  • [25] Effect of sonic application mode on the resin–dentin bond strength and nanoleakage of simplified self-etch adhesive
    Alexandra Mena-Serrano
    Eugenio Jose Garcia
    Alessandro Dourado Loguercio
    Alessandra Reis
    Clinical Oral Investigations, 2014, 18 : 729 - 736
  • [26] Effect of Bur Roughness on Bond to Sclerotic Dentin With Self-etch Adhesive Systems
    Luque-Martinez, I. V.
    Mena-Serrano, A.
    Munoz, M. A.
    Hass, V.
    Reis, A.
    Loguercio, A. D.
    OPERATIVE DENTISTRY, 2013, 38 (01) : 39 - 47
  • [27] Effect of the C-factor and Dentin Preparation Method in the Bond Strength of a Mild Self-etch Adhesive
    Marques, M. S. M.
    Kenshima, S.
    Muench, A.
    Ballester, R. Y.
    Rodrigues Filho, L. E.
    OPERATIVE DENTISTRY, 2009, 34 (04) : 452 - 459
  • [28] Aging Protocols and Their Effects on Bond Strength of Total-Etch and Self-Etch Adhesive Systems to Dentin
    Gomes, Isabella A.
    Gomes, Mario G. N.
    Amaral, Flavia L. B.
    Franca, Fabiana M. G.
    Basting, Roberta T.
    Bandeca, Matheus C.
    Diniz, Rafael S.
    Goncalves, Leticia M.
    Tavarez, Rudys R. de J.
    Turssi, Cecilia P.
    OPEN DENTISTRY JOURNAL, 2020, 14 : 408 - 415
  • [29] Bond strength studies of self-etch adhesive systems
    Bui, H
    Le, MA
    Shellard, E
    Ng, D
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A160 - A160
  • [30] Influence of different drying methods on microtensile bond strength of self-adhesive resin cements to dentin
    Kim, Young Kyung
    Min, Bong Ki
    Son, Jun Sik
    Kim, Kyo-Han
    Kwon, Tae-Yub
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (08) : 954 - 962