Enhancement of fracture healing by electrical stimulation in the comminuted intraarticular fracture of distal radius

被引:21
|
作者
Kohata, Kazuhiro [1 ,2 ]
Itoh, Soichiro [1 ,2 ]
Takeda, Shu [3 ]
Kanai, Misa [1 ]
Yoshioka, Taro [1 ]
Suzuki, Hiroyuki [1 ]
Yamashita, Kimihiro [2 ]
机构
[1] Kawakita Gen Hosp, Dept Orthoped Surg, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo 1010062, Japan
[3] Keio Univ, Sch Med, Dept Internal Med, Sect Nephrol Endocrinol & Metab, Tokyo, Japan
关键词
Alternating electric current (AC) stimulation; comminuted intraarticular fracture; distal radius fracture; wrist-bridging external fixator; palmar locking plate; EXTERNAL FIXATION;
D O I
10.3233/BME-130774
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effectiveness of an alternating electric current (AC) stimulation in prevention of bone deformity for comminuted intraarticular fracture of distal radius were verified by comparing postoperative results treated with a wrist-bridging external fixator combined with or without an AC stimulator (EF and NEF, respectively), and a palmar locking plate (LP). This study evaluated 92 cases (mean age 67.9 +/- 11.4 years) of type C2 and 60 cases (mean age 69.7 +/- 9.5 years) of type C3 distal radius fractures, as classified by the Association for Osteosynthesis. In total, 55 and 24 cases were treated with EF and NEF, respectively; and 73 cases were treated with LP. Callus appeared 27.5 +/- 4.6 days postoperatively and the external skeletal fixation period was significantly shorter in the EF group than in the NEF group. The decrease in radial length was significantly lower in the EF group when compared to the LP group. There were no significant differences among the groups for the other radiographic and functional parameters. AC stimulation combined to the external fixation may be a promising method to prevent postoperative deformity in the severely comminuted intraarticular fractures by accelerating callus maturation and facilitating new bone bridging across the gap of fracture site.
引用
收藏
页码:485 / 493
页数:9
相关论文
共 50 条
  • [31] Renal impairment and time to fracture healing following surgical fixation of distal radius fracture
    Sean Han Sheng Lai
    Camelia Qian Ying Tang
    Si Min Chiow
    Dawn Sinn Yii Chia
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1329 - 1334
  • [32] THE DISTAL OBLIQUE COMMINUTED TIBIA FRACTURE
    OSTRUM, RF
    ORTHOPEDICS, 1993, 16 (03) : 315 - 317
  • [33] COMMINUTED FRACTURE OF DISTAL PORTION OF FEMUR
    AUFRANC, OE
    JONES, WN
    BIERBAUM, BE
    BARR, JS
    RECORD, EE
    RADIN, EL
    BROWN, T
    GLIMCHER, MJ
    LOWELL, JD
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 205 (09): : 634 - &
  • [34] OPEN COMMINUTED FRACTURE OF DISTAL HUMERUS
    AUFRANC, OE
    JONES, WN
    BIERBAUM, BE
    MITAL, M
    MACAUSLA.WR
    BARR, JS
    REIDY, JA
    LOWELL, JD
    ROWE, CR
    CAVE, EF
    RISENBOR.EJ
    BROWN, T
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 204 (05): : 387 - &
  • [35] DYNAMIC EXTERNAL FIXATION FOR COMMINUTED INTRAARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS
    CLYBURN, TA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (02): : 248 - 254
  • [36] Ulnar Styloid Fracture With Distal Radius Fracture
    Wysocki, Robert W.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (03): : 568 - 569
  • [37] Management of Distal Ulnar Fracture Combined with Distal Radius Fracture
    Kim, Jae Kwang
    Kim, Jong-Oh
    Koh, Yong-Do
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02): : 155 - 160
  • [38] Electrical Stimulation for Fracture Healing: Current Evidence
    Goldstein, Christina
    Sprague, Sheila
    Petrisor, Bradley A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 : S62 - S65
  • [39] The science of electrical stimulation therapy for fracture healing
    Kuzyk, Paul R. T.
    Schemitsch, Emil H.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (02) : 127 - 131
  • [40] Comparison of External Fixation vs Volar Plating for Comminuted Fracture of the Distal End Radius
    Shah, Syed Habib Ullah
    Iqbal, Mazhar
    Muhammad, Eid
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (04): : 1342 - 1343