Modeling of DFIG Wind Turbine Based on Internal Voltage Motion Equation in Power Systems Phase-Amplitude Dynamics Analysis

被引:56
作者
Zhao, Mingquan [1 ,2 ]
Yuan, Xiaoming [1 ,2 ]
Hu, Jiabing [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Hubei, Peoples R China
关键词
Angle stability; double fed induction generator (DFIG) wind turbine (WT); internal voltage; phase-amplitude dynamics; voltage source converter; voltage stability; STABILITY ANALYSIS; GENERATORS; SCALE;
D O I
10.1109/TPWRS.2017.2728598
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the high penetration of power electronics based renewable energy generators being integrated into power grids, dynamic stability problems have become unprecedentedly challenging in modern power systems. Thus, an accurate description of equipment features for system dynamics analysis is desperately needed. Double fed induction generator (DFIG) wind turbines (WTs) are an example of this type of equipment with extremely complex characteristics. To analyze the effect of DFIG WT system behavior characteristics on angle and voltage stability issues, a small-signal DFIG WT model based on the internal voltage motion equation in the electromechanical time-scale is proposed. This approach models from the perspective of the equipment's internal voltage vector, and describes equipment features through the relationship between the input/output power and the internal voltage phase/amplitude. Understanding of the DFIG WT's internal voltage phase and amplitude motion is deepened by developing an analogy to a real dynamical system a rotor's rotation and the voltage across a capacitor. With this approach, the mechanism describing the dynamics of the internal voltage phase-amplitude is elaborated by a physical perspective, particularly system voltage amplitude dynamics. The factors influencing the phase-amplitude dynamics were investigated based on this model in a single-machine system.
引用
收藏
页码:1484 / 1495
页数:12
相关论文
共 25 条
[1]  
Adams J., 2012, P TRANSM DISTR C EXP, P1
[2]   Quasi-static stability of HVDC systems considering dynamic effects of synchronous machines and excitation voltage control [J].
Aik, Denis Lee Hau ;
Andersson, G. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) :1501-1514
[3]  
[Anonymous], MODELING GE WIND TUR
[4]  
[Anonymous], 2010, WECC WIND POW PLANT
[5]  
Duan X., 1991, P CSU EPSA, V3, P1
[6]   Inertia Provision and Estimation of PLL-Based DFIG Wind Turbines [J].
He, Wei ;
Yuan, Xiaoming ;
Hu, Jiabing .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (01) :510-521
[7]   Investigation of the Impacts of Large-Scale Wind Power Penetration on the Angle and Voltage Stability of Power Systems [J].
Hossain, M. J. ;
Pota, Hemanshu R. ;
Mahmud, Md. Apel ;
Ramos, Rodrigo A. .
IEEE SYSTEMS JOURNAL, 2012, 6 (01) :76-84
[8]   Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability Analysis [J].
Hu, Jiabing ;
Huang, Yunhui ;
Wang, Dong ;
Yuan, Hao ;
Yuan, Xiaoming .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (04) :1325-1336
[9]  
Hu Jingxin, IEEE T ENERGY CONVER
[10]   Definition and classification of power system stability [J].
Kundur, P ;
Paserba, J ;
Ajjarapu, V ;
Andersson, G ;
Bose, A ;
Canizares, C ;
Hatziargyriou, N ;
Hill, D ;
Stankovic, A ;
Taylor, C ;
Van Cutsem, T ;
Vittal, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (03) :1387-1401