Investigation of the Impacts of Large-Scale Wind Power Penetration on the Angle and Voltage Stability of Power Systems

被引:114
作者
Hossain, M. J. [1 ]
Pota, Hemanshu R. [2 ]
Mahmud, Md. Apel [2 ]
Ramos, Rodrigo A. [3 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Univ New S Wales, Sch Engn & Informat Technol, Australian Def Force Acad, Canberra, ACT 2600, Australia
[3] Univ Sao Paulo, Dept Elect Engn, Engn Sch Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
来源
IEEE SYSTEMS JOURNAL | 2012年 / 6卷 / 01期
关键词
Angle stability; FACTS devices and control interactions; voltage stability; wind generators; GENERATION;
D O I
10.1109/JSYST.2011.2162991
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.
引用
收藏
页码:76 / 84
页数:9
相关论文
共 25 条
[1]   Control design and dynamic performance analysis of a wind turbine-induction generator unit [J].
Abdin, ES ;
Xu, W .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (01) :91-96
[2]  
Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P1, DOI 10.1002/0470012684
[3]   An overview of wind energy-status 2002 [J].
Ackermann, T ;
Söder, L .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2002, 6 (1-2) :67-128
[4]   Large penetration of wind and dispersed generation into Danish power grid [J].
Akhmatov, Vladislav ;
Knudsen, Hans .
ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (09) :1228-1238
[5]  
[Anonymous], 2002, POWER SYSTEM CONTROL
[6]  
[Anonymous], 2005, POWER ELECTRONICS P
[7]  
[Anonymous], P IEEE POW EN SOC GE
[8]  
Custem TV., 1998, Voltage stability of the electric power systems
[9]  
Enslin J., 2003, 24 INT C POW EL INT, P1
[10]   Large-scale wind power integration in Norway and impact on damping in the Nordic grid [J].
Hagstrom, E ;
Norheim, I ;
Uhlen, K .
WIND ENERGY, 2005, 8 (03) :375-384