Mercury speciation: A spectroscopic essay using an analytical X-ray fluorescence spectrometer

被引:0
|
作者
Figueiredo, MO [1 ]
da Silva, TP [1 ]
Margarido, F [1 ]
机构
[1] IICT, Crystall Mineral Ctr, P-1000 Lisbon, Portugal
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray emission spectroscopy was used to assess mercury speciation through the peak intensity ratio L gamma(2,3,6,8)/L gamma(4) using mercury compounds (HgCl2, HgO, HgS) and the metal (HgO) as standards for different bonding states. Intensity measurements were performed with an analytical wavelength dispersive X-ray fluorescence spectrometer. An environmental application of the method illustrates its applicability.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [21] INVESTIGATION OF THE POSSIBILITY OF IMPROVING THE X-RAY FLUORESCENCE SPECTROMETER ANALYTICAL CHARACTERISTICS DUE TO USING THE SUPERFINE BERYLLIUM FOILS
    Mishin, V. V.
    Shishov, I. A.
    Kiselev, P. P.
    Matsinkevich, E. V.
    Rudnev, A. V.
    Bukin, K. V.
    MATERIALS PHYSICS AND MECHANICS, 2018, 36 (01): : 92 - 99
  • [22] Comparison of methodologies of gamma ray spectrometer and X-ray fluorescence
    D'Cunha, P.
    Narayana, Y.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2012, 50 (07) : 524 - 526
  • [23] A Low Energy X-Ray Fluorescence Spectrometer for Elemental Mapping X-Ray Microscopy
    Alberti, R.
    Longoni, A.
    Klatka, T.
    Guazzoni, C.
    Gianoncelli, A.
    Bacescu, D.
    Kaulich, B.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 839 - +
  • [24] Portable X-ray fluorescence spectrometer with an electric battery
    Kawai, J
    Yamada, T
    Fujimura, H
    BUNSEKI KAGAKU, 2004, 53 (03) : 183 - 186
  • [25] The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect
    Dong Yi-fan
    Fan Rui-rui
    Guo Dong-ya
    Zhang Chun-lei
    Gao Min
    Wang Jin-zhou
    Liu Ya-qing
    Zhou Da-wei
    Wang Huan-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (02) : 550 - 554
  • [26] A GEIGER COUNTER SPECTROMETER FOR X-RAY FLUORESCENCE ANALYSIS
    FRIEDMAN, H
    BRIKS, LS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1948, 19 (05): : 323 - 330
  • [27] A soft x-ray fluorescence spectrometer at BESSY II
    Follath, R.
    Bischoff, P.
    Eggenstein, F.
    Noll, T.
    Koennecke, R.
    Schlappa, J.
    Zeschke, T.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [28] New spectrometer for grazing exit x-ray fluorescence
    Perez, RD
    Sanchez, HJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07): : 2681 - 2684
  • [29] Spectroscopic Application of Realgar Using X-ray Fluorescence and Raman Spectroscopy
    Kadioglu, Yusuf Kagan
    Ustundag, Zafer
    Yazicigil, Zafer
    SPECTROSCOPY LETTERS, 2009, 42 (03) : 121 - 128
  • [30] Research on High Diffraction Efficiency X-ray Fluorescence Spot Generation Technology for X-ray Fluorescence Spectrometer
    Cao, Zhewei
    Zhang, Qi
    Gao, Ran
    Teng, Yun
    Rao, Lan
    Chang, Zeyuan
    2022 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE, ACP, 2022, : 1612 - 1616